UBX-22006906 -
R03
Page 28 of 44
C1-Public
5.3.3
Restore Eddystone Instance ID
All u-blox modules are delivered with a u-blox MAC address, which is written into the UICR register.
If the MAC address is accidentally erased, for example during a reflash of the software, this
information is lost. If this happens, the Eddystone Instance ID transmitted in the C209 advertising
beacon will not match the MAC address of the module. To correct this:
1.
Scan the QR code on the module label. The information in the code includes a code that includes
the MAC address (shown here in bold): H85(
CCF9578E0D89
)0400.
2.
While having a debugger connected to the SWD interface of the board enter these commands to
reinstate the MAC address
CCF9578E0D89
into the UICR of the module:
nrfjprog --memwr 0x10001080 --val 0x8E57F9CC
nrfjprog --memwr 0x10001084 --val 0xFFFF890D
Another example for which the MAC address given in the scan code is
0123456789AB
:
nrfjprog --memwr 0x10001080 --val 0x67452301
nrfjprog --memwr 0x10001084 --val 0xFFFFAB89
3.
After writing the MAC address, reset the module. The module now transmits the correct
Eddystone Instance ID for the C209 tag.
Содержание XPLR-AOA-3
Страница 31: ...UBX 22006906 R03 Page 31 of 44 C1 Public B C209 schematics...
Страница 32: ...UBX 22006906 R03 Page 32 of 44 C1 Public C EVB ANT 1 schematics...
Страница 33: ...UBX 22006906 R03 Page 33 of 44 C1 Public...
Страница 34: ...UBX 22006906 R03 Page 34 of 44 C1 Public...
Страница 35: ...UBX 22006906 R03 Page 35 of 44 C1 Public...
Страница 36: ...UBX 22006906 R03 Page 36 of 44 C1 Public...
Страница 37: ...UBX 22006906 R03 Page 37 of 44 C1 Public...
Страница 38: ...UBX 22006906 R03 Page 38 of 44 C1 Public...
Страница 39: ...UBX 22006906 R03 Page 39 of 44 C1 Public...
Страница 40: ...UBX 22006906 R03 Page 40 of 44 C1 Public...
Страница 41: ...UBX 22006906 R03 Page 41 of 44 C1 Public...
Страница 42: ...UBX 22006906 R03 Page 42 of 44 C1 Public...
Страница 43: ...UBX 22006906 R03 Page 43 of 44 C1 Public...