7
Extend setting
*
$$$$$$
,008,ABCDEFG#
A=0, Disable machine information
report function which get machine
information SMS by Calling
A=1, Enable machine information
report function which get machine
information SMS by
Calling(default)
B=0
,disable GPRS ACK
function(default);
B=1,enable GPRS ACK function
Note:
the machine once every send
GPRS data to the server, the server
must
respond
@ACK,serial
number(Packet index)#
to the
machine, then the machine will
continue to send next GPRS data to
the server.
C/D/E/FG=0
8
Set APN,Username,Password
*
$$$$$$
,011,APN,Username,Pass
word#
APN : APN string (must < 28
chars)
User name: Your username (must
< 28 chars)
Password: Your password (must
< 28 chars)
* If haven't username or
password, then left it blank.
For example:
*000000,011,CMNET,,# (It haven't
username and password)
9
Set IP Address & port number
*
$$$$$$
,015,X,IP,PORT#
X=0 use IP connect the server
X=1 use DN connect the server
IP : xxx.xxx.xxx.xxx
DN:(domain name)
www.xxx.com
PORT : [1,65535]
10
Set the time intervals of GPRS
Data
*
$$$$$$
,018,X#
X (3 Digital)
[1,60] Time interval
(Unit: min,default:5)
11
Set the GPRS mode
*
$$$$$$
,019,X#
X=0, Use the UDP mode
X=1, Use the TCP mode(default)
12
Set the temperature & humidity
SMS alarm function
*
$$$$$$
,020,X,Y#
X=0, disable this function(default)
X=1,enable this function