background image

Tzonedigital_TT11 V1.5 June9, 2016

TZ-TT11

Temperature & humidity Transmitter

User Guide V1.5

1. Product overview

Temperature Transmitter (hereafter referred as TT11) is with one digital temperature

/humidity transmitter, TT11 embedded GSM module, need to inset SIM card use,

built-in 3.7V/4500mAh rechargeable battery and can connect 5V external power for

charging. TT11 is with long standby time and only wakes up when it is

time to send data, or when the user operates it. Other than this, it is in sleep state so

can be used for a longer time to bring you more convenience.

Содержание TZ-TT11

Страница 1: ...temperature humidity transmitter TT11 embedded GSM module need to inset SIM card use built in 3 7V 4500mAh rechargeable battery and can connect 5V external power for charging TT11 is with long standby...

Страница 2: ...SM antenna Built in Flash Memory 32MBit Temperature precision 0 3 Detect Temperature range 40 125 Operating Temperature Range 20 60 humidityprecision 3 Detect humidity range 0 100 Power Consumption Ac...

Страница 3: ...e digital thermometer D SIM card Insert SIM card send the GPRS data 4 Indicator status Red LED indicating change status Off No charge the charge is complete On Charging Blue LED indicating Temperature...

Страница 4: ...MCC 2byte MNC 2byte Extension bits A State data length 2byte Alarm type 1byte Terminal information 1byte GMS signal strength 1byte GSM state 1byte Battery voltage 2byte Temperature 2byte humidity 1by...

Страница 5: ...y 3 digital 04 60 mean MCC is 460 MNC 2 Variable Mobile Network Code 2 or 3 digital if the first digital is 8 means MNC is 3 digital if the first digital is 0 mean MNC is 2 digital 87 56 means MNC is...

Страница 6: ...t mark in the highest bit 1 disconnect 0 connect negative positive mark 1 mean the temperature is negative 0 mean the temperature is positive Remaining is the temperature value convert to HEX first an...

Страница 7: ...usernameand password are empty After you send the command of SMS to device it will reply to your mobile phone Receive 011 OK 000000 011 cmnet If you send the command of USB to device the serial port...

Страница 8: ...me interval unit is min For example 000000 018 1 The device will send GPRS every1 minute and no times limit After you send the command of SMS to device it will reply to your mobile phone Receive 018 O...

Страница 9: ...unit default 20 C must be bigger than D if Humidity exceed A B it will send one alarm data X 1 60 TT11 more than threshold change into Xmin send a GPRS data unit min default 1 4 Set low power alarm Wh...

Страница 10: ...r C D E FG 0 8 Set APN Username Password 011 APN Username Pass word APN APN string must 28 chars User name Your username must 28 chars Password Your password must 28 chars If haven t username or passw...

Страница 11: ...SB configure cable read the machine records in the Flash to the computer 8 Instruction With the battery in TT11 machine running when TT11 completes initialization and sends the first data it will slee...