RD06 user manual V 1.4

- 9 -

043

RS485 Anti-Reread

*

$$$$$$

,043, X#

X:[0-3600],unit:s,default:0
RS485 send once tag data
within this time period, no
matter RD06 receive this tag
many times.

Only use in RS485 Report
automatically mode

044

Max tag online time

*

$$$$$$

,044, X#

X:[0-86400],unit:s,default:300
RD06 will think tag is offline if
it do not receive this tag
within this time period

Only use in RS485 modbus
mode

127

GPRS sending interval when no
power

*

$$$$$$

,127,X#

X=0,Disable this function
(default)
X:[10,6000]
GPRS interval,
unit: s;

136

Enable RF function

*

$$$$$$

,136,X#

X:0:disable RF function
1:enable RF function

default

138

Choose TAG type

*

$$$$$$

,138,X#

X:
0:Reserved
1:Reserved
2:Reserved
3:Reserved
4:Reserved
5:Reserved
6:Reserved
7:TAG06/06B

default

141

Set tag’s baud rate

*

$$$$$$

,141,X#

X:0,1K;
X:1,2K;
X:2,10k;
X:3,38.4k,default;
X:4,100k;

142

Set Tag temperature and
humidity alert function

*

$$$$$$

,142,X,Temp_H,Temp_L,

RH_H,RH_L#

X=0,disable (default)

X=1,

If tag’s temperature
exceed Temp_H

under

Содержание TZ-RD06

Страница 1: ...Jan9th 2018 RD06 user manual V 1 4 1 RD06 user manual V1 4...

Страница 2: ...band 850 900 1800 1900MHz RS 485 1 digital output can be used to alert Kinds of alarm method External special USB configure interface user can configure RD06 operate mode Prevent collision advanced t...

Страница 3: ...9th 2018 RD06 user manual V 1 4 3 Operating temperature 40 C 60 C Operating humidity 5 95 non condensing Built in battery 3 7V 850mAh Dimension 112mm 105mm 27mm 4 Definition of interfaces 4 1 Appearan...

Страница 4: ...a 4 3 Expand interfaces Interfaces Functions 1 RS 485B RS 485B 2 RS 485A RS 485A 3 GND GND 4 OUT Output 5 GND GND 6 12V 12V output 5 LED light indicating status Blue light RF RF light status Explanati...

Страница 5: ...mands is ASCII can be set via SMS or can be set by serial port and GPRS Note the default has been configured for 5 minutes to send a GPRS data to the Tzone platform If the SIM card needs to set APN to...

Страница 6: ...ol will shows CMD bytes 14 000000 011 cmnet ComdType 011 SETAPN APNnumber cmnet Username Password Note is RD06 s password and the initial password is 000000 NO Instruction Format Note 001 Modify user...

Страница 7: ...GSM module support the four frequency 850 900 1800 1900 then you could set the parameter to S 1 011 Set APN Username Password 011 APN Username Pass word APN must 28 character Username must 28 charact...

Страница 8: ...unction 030 ABCDEFG A 1 Enable SMS alarm for temperature and humidity alert default B 1 Enable SMS alarm for power off default C 1 Enable SMS alarm for low voltage alert default D 0 E 0 F 0 G 0 040 RS...

Страница 9: ...nly use in RS485 modbus mode 127 GPRS sending interval when no power 127 X X 0 Disable this function default X 10 6000 GPRS interval unit s 136 Enable RF function 136 X X 0 disable RF function 1 enabl...

Страница 10: ...rature exceed Temp_H RD06 alert when temperature under Temp_L RD06 relieve alert If tag s humidity exceed RH_H RD06 alert when humidity under RH_L RD06 relieve alert X 4 If tag s temperature under Tem...

Страница 11: ...character 145 Delete a TAG 145 X X Channel 1 100 146 Delete all TAG 146 1 147 Read all added TAG 147 1 148 RF reboot 148 X X 1 1440 default 5 unit min RF module will reboot if RD06 can not receive an...

Страница 12: ...se register an account and add the TAG via its ID to the platform The default data transmission interval of the TAG is every 1 minutes And the default data transmission interval of the RD06 is every 5...

Страница 13: ...Jan9th 2018 RD06 user manual V 1 4 13 For more details please check the Help button in the upper right corner of the temperature and humidity monitoring platform...

Отзывы: