5
TAG ID: received tag05/06 ID
TAG status
:
1 byte (convert to binary)
bit7: Battery voltage status, 1-low Voltage, 0- Voltage normal
;
bit6: Temperature status,1- Temperature more than set high and low
temperature threshold, 0- Temperature normal.
bit5-bit0: reserved;
Battery voltage: 2 byte, Unit: 1mv, 0C 50 means voltage is 3.152V(convert to
decimal)
;
Temperature:2 byte, convert to binary, the first bit of temperature means
normal/abnormal(0-normal,1-abnormal); the second bit of temperature
means po)/negative(-) (0-positive,1-negative) ; after the third bit of
temperature means real temperature, unit:0.1
℃
(convert to decimal);
For example: 01 64 means +35.6
℃
, 41 64 means -35.6
℃
, 80 00 means
abnormal;
Humidity: 1 byte, unit: %;
RSSI: 1 byte,unit:-dBm;
Check code: 1 byte, and the accumulation of all the data before;
End code: 0x03.
The data sample:
7E0D12345662160179000E1000EC4F7203
7E
Begin character
0D
Data length
123456
TZ-RD05
ID
62160179
Tag ID
00
TAG status
0E10
Battery voltage
00EC
Temperature
4F
Humidity
72
Check code
03
End code
5 Prepare for configuration
5.1 Ethernet usage
Explain: The language of Ethernet conversion module is Chinese, so if you do
not understand the language, please contact
Tzone technical personnel.