11
default, 0 will disable this
function
01
Set ID
*01,X#
X:6bits, range [A-F] and
[0-9]
04
Set the serial data
contain RD05’s ID
*04,X#
X:
0-No,default
1-Yes
06
Set the print mode
*06,X#
X:
0-hex (default)
1-ASCII
12
R485 setting
*12,A,B,C,D#
A:baud,[600,128000]
115200 (default) ;
B:digital bits
0-8bit(default) ,
1-9bit;
C:stop bits
0-0.5bit,
1-1bit(default) ,
2-1.5bit,
3-2bit
D:parity bits,
0-none(default) ,
1-Even,
2-Odd
13
data mode setting
*13,X#
X:0- active mode(default)
1- Passive mode
About passive mode: need
upper computer send command
to read data.
Reading command is, AA+ ID
of RD05+ 03 (HEX)
For
example:AA123403(HEX)
14
Output working mode
setting
@14,X,Y,Z#
X:connect
time,
unit
1s,[0,60];
Y:disconnect time,
unit
1s,[0,60];
Z:duration,
unit
s,
[1-999],999 Indicates that the
action has been continuous
21
Whether to enable the
RSSI values
*21,X#
X-0, Disable(default);
X-1, Enable;
Query command
#D5X
X:
command’s
NO.
For
example, *D51 can query the