Malfunctions
Malfunction
Possible cause
Solution
Feed motor fails to build
up power
Remote controller potentiometer is de-
fective or in the 0-position
X
Contact TYROLIT Hydrostress AG after-sales service.
X
See chapter 4.5
Automatic feed:
Power range indicator within the red
zone
X
Blade jammed, switch off main motor and loosen the
deadlock
Defective motor
X
See the chapter entitled “Reacting to indicators” Flash
code 3x.
X
Contact TYROLIT Hydrostress AG after-sales service.
No water outlet
Water line or filter clogged
X
Clean the water line.
X
Clean the water filter (see chapter 5.5)
Water valve on the supply or water hose
is closed
X
Open the water valve.
Insufficient water pressure
X
Make sure that the water pressure is at least 2 bar.
Defective switch on the remote con-
troller
X
Contact TYROLIT Hydrostress AG after-sales service.
Defective watervalve
X
Contact TYROLIT Hydrostress AG after-sales service.
Uncontrolled water outlet
• Water valve on the wall saw head is
faulty
• Defective switch on the radio remote
controller
X
Stop water outlet using the hose water valve.
X
Contact TYROLIT Hydrostress AG after-sales service.
• Blade guard not assembled
X
Assemble the blade guard
Group alarm on the remote controller
X
See the chapter entitled "Reacting to indicators".