TYROLIT Hydrostress AG
Page 22
Floor Saw FSD1049
8
Malfunctions
Malfunction
Possible cause
Solution
Floor saw does not operate
EMERGENCY STOP
switch has been pressed.
►
Release
EMERGENCY STOP
switch.
Saw blade jammed
Saw blade is jammed in the cutting material
►
Reverse the floor saw.
►
If necessary release the saw blade by
rocking.
►
If necessary stop the motor, disassemble
the saw blade and release this
individually from the cutting material.
Saw blade does not rotate even
though the motor is running
Belt tension too slack
►
Tension or replace belt.
Pulling pin on the anchoring flange has
sheared off
►
Mount new anchoring flange.
Feed not working
Operation of the control rods impaired
►
Check control rods and repair as
necessary.
Defective hydrostat
►
Check hydrostat and if necessary have
this repaired by a TYROLIT Hydrostress
engineer.
Defective chain
►
Have the chain replaced by a TYROLIT
Hydrostress engineer.
Main motor belt slipping
►
Check belt for wear and if necessary
have this replaced by a TYROLIT
Hydrostress engineer.
►
Increase belt tension as necessary.
Motor running off centre
Wrong fuel
►
Switch off motor immediately and
change fuel.
Diesel filter blocked
►
Have diesel filter changed.
Battery display lights
Defective contacts on the connection
between battery and generator
►
Check contacts and re-establish these as
necessary.
Inadequate battery charging
►
Charge or change battery.
Oil temperature display lights
Oil temperature too high
►
Allow floor saw to run under no load
until temperature display goes off.
Too little oil
►
Top up oil.
Oil pressure display lights
Defective oil pump
►
Have oil pump changed.
Motor temperature display pointer in
red zone
Motor overloaded
►
Allow motor to run under no load for a
few minutes.