17
O07
Foot lifter release
time
5~30(s) 20
When
O06
is “ON”, the Foot
solenoid will be released
automatically after the time
desired.
O09
Duty of RVS output
10~99
(%)
50
The duty cycle of PWM for signal of
reverse solenoid. The power will be
greater if this value is bigger, at the
same time, the heat is more.
O10
RVS auto release
ON~OFF
ON
When it is “ON”, the reverse
solenoid will be released
automatically after the time desired.
O11
RVS release time
5~30(s)
10
When
O10
is “ON”, the reverse
solenoid will be released
automatically after the time
desired.
O12
Tacking speed
limitation with 1
stitch
200~2500
(s/m)
1300
If the stitch of start tacking, end
tacking or bar tacking contains 1
stitch, the tacking speed will never
exceed this parameter.
O13
Tacking speed
limitation with 2
stitches
200~2500
(s/m)
1800
If the stitch of start tacking, end
tacking or bar tacking contains 2
stitches, the tacking speed will
never exceed this parameter.
O14
Tacking speed
limitation with 3
stitches
200~2500
(s/m)
2000
If the stitch of start tacking, end
tacking or bar tacking contains 3
stitches, the tacking speed will
never exceed this parameter.
O15
Parameter encrypt
ON~OFF
OFF
See 7.9.
O16
System speed
limitation
200~5000
(s/m)
4500
Every speed will never exceed this
parameter.
O17
Initialization of
parameters
ON~OFF
OFF
When it is “ON”, all parameters will
initial to default value during next
power on.
O18
Safety SW. mode
0~1
1
0: Normal close, 1: Normal open.
O19
Identifier enable
ON~OFF
ON
“ON” to enable identifier function.