background image

RANGE HOOD INSTALLATION 

RANGE HOOD INSTALLATION 

D

t

1

(Outer Chimney) 

臣三.

Core Body 

WALL

Step 3: 

Locate the 6" round aluminum duct (F) and 

attach it to the top air outlet on the main body 

of the range hood with HVAC foil tape 

(not included). Make sure it is connected 

tightly

Step 4: 

Place the bottom of Outer Chimney into Core 

Body's seating located near vent hole 

Then Insert the Inner Chimney cover into the 

Outer Chimney Cover. 

Note that the Inner Chimney cover must slide 

into the Outer Chimney cover's orientation slot. 

(see step 7 for mounting bracket install) 

Step 5: 

A.Extend the inner chimney cover to the

height at which it will touch the ce由ng

id

. Usin

th

pencil, place a small mark on each s  e of 

chimney cover which is level with the screw holes 

of the chimney. Now slide the inner chimney 

cover down 

B. Using a pencil, place a small mark on the wall

on each side of the chimney

C. Align the middle of the Inner chimney

bracket (H) with the drawn line and make

a mark where each screw hole in your

wall will need to be drilled for mounting of

the bracket

D. Drill 1 /4" holes at each marked location

The drilled hole should be slightly smaller

than the diameter of the anchor

E. Insert anchors into each drilled hole 

F. Align Inner chimney bracket (H) with the 

drilled holes and firmly screw it into place

111 

,v 

\ 

A

i

outlet 

A

 

B

Use 3/8" 

g

10 

Installations : 

Measure the distance between stove top and the 

bottom of range hood. A distance of 24" to 32" is 

recommended*. *Due to different ceiling height 

configurations, recom-mended height may not be 

applicable. 
I. mark the 

leveling

 point of the hood. Position

two mounting screws on the wall, leaving 1/8"

space away from the wall.
2. Measure the width of the chimney then attach

the 

chimney

 -mounting brackets to the wall as

high as you want the upper chimney to be.

NOTE: Use threaded drywall anchors only 

when 

mounting

 the hood on sheet rock. 

Mounting the hood on wall studs or 

lumbar 

is 

highly recommended

3. Align hood-mounting holes to the screws on

the wall and hook the hood into place. Tighten

 

screws to secure hood to the wall. 

      

CAUTION: Make certain the range hood is 

secure before releasing!

SAFETY WARNING: Risk of electrical shock. This range hood must be properly 

grounded. Make sure this is done by 

qualified 

electrician in accordance with all 

applicable national and local electrical codes. Before connecting wires, switch power 

off at service panel and lock service panel to prevent power from being switched on 

accidentally. 

6. Store excess wires in the wiring box.
7. Install both chimneys and tighten screws to secure the lower chimney to the range hood

as shown in Figure 5.
8. To avoid scratching the chimney, extend the upper chimney slowly and carefully to the

chimney-mounting bracket and tighten screws as shown in Figure 6.

10

     

11

5. Connect the range hood to a designated standard outlet (please refer the product label

for the suitable voltage of this unit) or cut off the plug and connect three wires  to house

wires and cap with wire connectors. Connect according to colors.

4.Connect the venting duct between the hood and the exhaust opening either on the 

ceiling or wall. Use aluminum tape to make all joints secure and air tight.

Содержание KMC03-30

Страница 1: ...Model KMC03 30 KMC03 36 Installation Guide Users Manual IMPORTANT Read and save these instructions NOTICE For residential use only Installer Leave this guide with the homeowner Homeowner Keep this guide for future reference ...

Страница 2: ...thorough quality inspection and testing Our are ready to answer any questions you may have regarding how to install use and care for your products We hope that this manual will help you learn to use the product in the safest and most effective manner If you have any questions or concerns please contact our Customer Support at support itylza com TABLE OF CONTENTS SAFETY INSTRUCTIONS 4 STAINLESS STE...

Страница 3: ... prevent back drafting Follow he heating equipment manufacturers guideline and safety standards such as those published by the National Fire Protection Association NFPA the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities E When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities F Ducted...

Страница 4: ...L U L s a n m a i s _ MAIN PARTS 1 Top Chimney Inner Chimney 3 Exhaust Pipe 4 Core Unit 5 Grease Filters 三 三 All inch measurements are converted from millimeters Inch measurements are estimated All measurements in are millimeters 6 7 MODEL NO KMC03 30 KMC03 36 ...

Страница 5: ...ce由ng If your ceiling leaves the hood a few inches higher or lower than 24 to 36 you can still install it without a major loss of performance 3 For optimal performance do not over extend the exhaust tube and avoid unnecessary bending Fig 3 4 After hanging the unit on the wall ensure the range hood is straight and leveled Fig 4 5 The air outlet must be connected to chimney flumes or combustion gas ...

Страница 6: ...ng height configurations recom mended height may not be applicable I mark the leveling point of the hood Position two mounting screws on the wall leaving 1 8 space away from the wall 2 Measure the width of the chimney then attach the chimney mounting brackets to the wall as high as you want the upper chimney to be NOTE Use threaded drywall anchors only when mounting the hood on sheet rock Mounting...

Страница 7: ... touch once the timer has a default setting of 15 minutes use button A or B to increase or decrease time duration depending on how much time you require D To press Light to open or close the lamp The luminance of lighting can be adjusted from 0 to I 00 as wanted by touching Light E Auto Power off press to tum off the fan automatically after 3 minutes F Power Gesture Control press to turn the contr...

Страница 8: ...t A Replace with a new LED lamp assembly Phillips Screwdriver B Remove baffle filters reach 1ns1de behind the control panel and locate the wire with clip behind the light housing Make sure the light is securely plugged in 18 三 REPLACING LIGHT BULBS CAUTION LAMP UNIT MAY BE HOT WAIT UNTIL THE UNIT IS COOL BEFORE ATTEMPTING TO REPLACE THE LEO LAMPS MAKE SURE THE UNIT IS POWERED OFF AND UNPLUGGED 1 R...

Страница 9: ...O REGISTER VISIT https itylza com c LISTED Correct Disposal of this product This marking indicates that this appliance should not be disposed with other household wastes To prevent possible harm to the environment or humanhealth from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources 三 19 20 三 16 17 ...

Отзывы: