Installation instructions for h1
The h1 can be placed inside or outside the
sauna room and outside the steam room. If
the h1 is placed inside a sauna room, the
top edge must not be more than 90 cm
b
th fl
(fi
1)
Steam room
Sauna room
above the floor (figure 1).
Begin by fitting the rubber seal if this is
necessary (figure 2).
English
Figure 1
This seal should be fitted if the
h1
is to be used in a humid environment. Screw the mounting
plate into place at a suitable location, making sure that the electric cables pass through the
opening. Note that the plate must be oriented so that the hole for the retainer screw is on the
underside. Screw the electrical connections into place on the terminal block (figure 3) as shown
in the wiring diagram. See wiring diagram delivered with the heater/steam generator.
To facilitate this process, the
t
i
l bl
k
b
Figure 2
Figure 3
Figure 4
Figure 5
terminal block can be
removed from the circuit
board. Slide the glass and
circuit board of the control
panel upwards into place on
the mounting plate and
press the bottom edge into
place (figure 4). Screw the
retainer screw into place
(figure 5).
Installation
See wiring diagram delivered with the heater/steam generator.
External switch
It is possible to connect an optional external switch to the h1 panel. Indication must be connected
between (+)19 and (-)21, (3 V/DC max 0.3W 100mA). See wiring diagram delivered with the
external switch (Art.no. 9090 8045).
Momentar connection s itches on and off respecti el each time it is pressed
Momentary connection: switches on and off respectively each time it is pressed.
Constant connection: the panel is activated for as long as the connection is maintained, up to the
maximum running time that has been set.
When the heater is on, the indicator lamp on the external switch lights up. If the panel has been
programmed to start at a later time, the indicator lamp flashes.
An external switch can not be used with Combi Compact.