Additional Information you may find useful

 

1.

 CONTROLLER: 

The 60A MPPT controller turns off power to the 30A 

load if the voltage gets too low and automatically turns the load power 

back on when the voltage recovers. This protects battery from overdis-

charge and increases battery life and performance.

 

2.

Fuse:

  There is a fuse in the battery cable (30A).The fuse is in

-

line 

with battery power. If fuse is blown there was some sort of short in the 

battery connection and the controller will appear dead. Replace with a 

30A fuse.

 

3. 

CAPACITY: 

The RemotePro

® 

 is rated at 50W to 100W  continuous 

power output with 6 hours of peak sun per day. (Depending on the con-

figuration).

 

4.

 

VENTING: 

The  enclosure  is  vented  thru  the  PowerVent

™. 

The 

12/24V fan is thermostatically controlled and will turn on when the tem-

perature inside the enclosure exceeds 45° C.

 

5.

  

BATTERY MAINTENANCE: 

The batteries used in the RemotePro

® 

 

systems don

t require any maintenance. They should last up to 5 years 

in normal use. 

 

NOTE: Never store batteries for a long time in a discharged state 

or it will kill the battery. Especially in cold temperatures.

 

6. Remote Monitoring: 

There is an RS485 port on the MPPT control-

ler. This port is a special port to interface to the Tycon 

TPDIN

-

Monitor

-

WEB3 V2 

using a 

TPDIN

-

CABLE

-

485 

cable for remote monitoring via 

Ethernet.

 

The RS485 port can also be used with the Tycon 

TP

-

SC

-

WiFi 

to pro-

vide connectivity to a wireless network. To provide a connection to a 

PC, use the 

TP

-

SC

-

USB

-

RS485

. Software and instructions are availa-

ble at tyconsystems.com.

 

7.  BATTERY OVERDISCHARGE

: We highly recommend hooking all 

equipment loads to the controller load output. This output will discon-

nect the load if the battery voltage drops below 11V (12V battery) or 

22V (24V battery) or 44V (48V battery) and this will protect the battery 

from over

-

discharge. If batteries get completely discharged (<10V) be-

cause the equipment was connected directly to the battery, you will re-

duce the battery life and you will most likely need to recondition them 

with a good quality 10A automotive battery charger. Avoid charging for 

longer than 24hrs to avoid battery damage. Once they are back to a 

normal operating range, the integrated charge controller will maintain 

the charge.

 

 

Содержание RemotePro RPSTL 12

Страница 1: ...ith overhead power lines lights and power circuits Contact with power lines lights or power circuits may be fatal We rec ommend to install no closer than 20 feet to any power lines Safety For your own protection follow these safety rules Perform as many functions as possible on the ground Do not attempt to install on a rainy windy or snowy day or if there is ice or snow accumulation at the install...

Страница 2: ... Solar panels should face south if you are in the northern hemisphere When mounting the enclo sure be sure to mount low enough so the door of the enclosure clears the solar pan els when opened We suggest mounting the enclosure so it is shaded by the panels during the day STEP 2 Attach the solar panels to the solar panel mount so that the wire junction box is towards the top or side Connect the sol...

Страница 3: ...he batteries if 48V configuration Be sure to observe proper polarity RED CAUTION Reverse polarity connections will damage the equip ment STEP 9 Connect the included solar panel cable to the MPPT controller PV inputs Red to PV Don t connect the solar cable to solar panel connect ors until the controller is connected to the batteries STEP 10 Connect your load to the MPPT Controller load output When ...

Страница 4: ...anging this to a fixed 24V if using a 24V battery configuration or fixed 48V if using 48V configuration so that the system can recover automatically if by chance the batteries get drained completely See MPPT controller user manual for specific instructions STEP 13 Make sure lid gasket is clean and free from any particles then carefully close the cover making sure that wires are clear of the seam a...

Страница 5: ...5 720W Two Panel Configuration for 12V or 24V or 48V Battery Configurations 1440W Four Panel Configuration for 24V or 48V Battery Configurations ...

Страница 6: ...6 CAUTION Be sure to connect the battery to the controller first and dis connect it last Connecting solar panels to the controller without the bat tery connected could damage the controller ...

Страница 7: ...7 ...

Страница 8: ...8 ...

Страница 9: ...r a long time in a discharged state or it will kill the battery Especially in cold temperatures 6 Remote Monitoring There is an RS485 port on the MPPT control ler This port is a special port to interface to the Tycon TPDIN Monitor WEB3 V2 using a TPDIN CABLE 485 cable for remote monitoring via Ethernet The RS485 port can also be used with the Tycon TP SC WiFi to pro vide connectivity to a wireless...

Страница 10: ...t efficient operation is achieved by wiring 12V or 24V panels in series On 24V panels the controller can only handle two panels in series because four 24V panels in series would exceed the controller max voltage So in 4 panel configurations wire the panels in series parallel configuration C My system turns off at night and comes back on in the morn ing This is a sure sign that the solar panels and...

Страница 11: ...d AGM Battery Life 5 Years Controller Type 60A MPPT Temperature Compen sated Over Voltage Protection 16V 32V 64V Bulk Charge 14 4V 28 8V 57 6V Float Charge 13 8V 27 6V 55 2V Over discharge protection 11 1V 22 2V 44 4V Over discharge recovery volts 12 6V 25 2V 50 4V Controller Self Consumption 1W Enclosure Type Powder Coat Steel Wind Survivability 90MPH Operating Temperature 30 C to 60 C 12 24V 60A...

Страница 12: ...per installation misuse poor site conditions faulty power etc Lightning or weather damage Physical damage to the external internal parts Products that have been opened altered or defaced Water damage for units that were not mounted according to user manual Usage other than in accordance with instructions and the normal intended use Tycon Systems 14641 S 800 W Bluffdale UT 84065 support tyconsystem...

Отзывы: