If  you  connect  a solar  panel  or  wind  turbine  to the  BATTERY terminal at the same 

time, if AC failed, when the battery voltage lower than  40V, the  LOAD output will 

turn off, but if the output voltage of the solar panel or wind turbine is higher than the 

battery voltage, the battery will be charged by the solar panel or wind turbine, when 

the battery voltage is back to 51V, the LOAD output will recover automatically. 

The maximum load of the PS is around 300W, which means 4A maximum DC output 

on  LOAD  and  6A  maximum  charge  current  on  BATTERY.  If  the  load  draws  4A 

output, then the charge current will be limited to around 2A, if there is no load, then 

charge current may be up to 6A maximum. 

The  output  voltage  on  LOAD  terminal  is  regulated  at  48V±0.5V,  with  over  voltage 

protection, over current protection and short circuit protection.     

The charge voltage for wet battery is 58V, floating voltage is 53V. 

The charge voltage for gel battery is 56.8V, floating voltage is 54V 

When  the  charger  is  in  charging  mode  and  charge  current  is  more  than  1.4A,  the 

CHG indicator light will be YELLOW, when charge current  is lower than 1.0A, the 

charger turns to maintenance mode, the CHG light is off and CHD light is GREEN.     

All  LED  indicators  will  turn  off  when  AC  fails  except  BATT  and  battery  type 

indicator (WET or GEL).   

If no battery is connected on BATTERY terminal, then there will be no output on the 

terminal.   

The cooling fan on the model will operate when the unit is turned on. The speed of 

the fan varies depending on the temperature control circuit. 

Содержание TP-BC48-300

Страница 1: ... Net weight only 4 63 lbs 2 1kg Dimensions 252 54 190 m m W H D Over Voltage protection Over Current protection Quiet Internal Cooling Fan Input Voltage Selectable AC input voltage 115 Vac at 50 60Hz 230 Vac at 50 60Hz Super Regulation Works with AC input from 90 to 265Vac Back up Power Supply System Compatible with Solar and Wind Charge Controllers ...

Страница 2: ...n is incorrect 3 4 CHD Floating Indicator Light GREEN when battery is in floating mode 3 5 CHG Charging Indicator Light YELLOW when battery is in charging mode 3 6 WET Battery Type Indicator Green LED light on when battery type selector is set on WET position 3 7 GEL Battery Type Indicator Yellow LED light on when battery type selector is set on GEL position 4 LOAD Output Terminal Block For connec...

Страница 3: ...ke sure it is as the same polarity as battery Now plug in the power cord to AC outlet turn the PWR switch to the ON position Turn on your device now OPERATION The PS works as a DC UPS Uninterruptible Power Supply or as a backup power supply system When AC power is applied normally the model offers a regulated 48V DC output at LOAD terminal for devices and a charging current output on BATTERY termi...

Страница 4: ...be up to 6A maximum The output voltage on LOAD terminal is regulated at 48V 0 5V with over voltage protection over current protection and short circuit protection The charge voltage for wet battery is 58V floating voltage is 53V The charge voltage for gel battery is 56 8V floating voltage is 54V When the charger is in charging mode and charge current is more than 1 4A the CHG indicator light will ...

Страница 5: ... battery type selector when charging 4 The model has a 6 amp AC input fuse inside of the unit To replace the fuse you should remove the old fuse by opening the case and replace it with a new 6 amp fuse 5 The cables for battery connection or device to the PS should be 18AWG min Please keeping the connect points clean to avoid spark or electrical leakage 6 Use the proper voltage solar panel or wind ...

Страница 6: ...s causing a spark Battery Low Voltage protection When the AC is OFF or has failed if the battery voltage is lower than 40V 0 2V the model will turn off the output on LOAD When AC returns or the battery voltage returns to 51V 0 2V then the output on LOAD will recover automatically Load Over Current Protection the model will automatically shut down if the load is over 4A when the load is reduced the...

Отзывы: