9. Recommended long term storage procedure

The following are the factory's recommendations for storage procedures to retain maximum
product integrity during long term storage of 1 to 5 years.

Handwheel or bevel gear operated valves

A. Storage facility: The preferred storage

location is a clean, dry protected
warehouse. If valves are to be stored
outside, precautions should be taken to
keep valves clean and dry. Standard
packaging materials provided in valve
shipment can not be considered sufficient
for outdoor storage. 

B. Equipment orientation: Valves may be

stored in the vertical or horizontal position.

C. Preparation for storage: Valves may be

stored as shipped, provided the above
Storage Facility and Equipment Orientation
instructions above are followed. If valve
packaging is altered or removed for
receiving inspection, repackage valve as
originally received.

D. Storage inspection: Visual inspection shall

be performed on a semiannual basis and
results recorded. Inspection as a minimum
shall include reviewing the following: 

Packaging 
Flange Covers 
Dryness
Cleanliness

E. Maintenance: Maintenance shall consist of

correcting deficiencies noted during
inspection. All maintenance shall be
recorded. Contact factory prior to
performing any maintenance if valve is still
covered under warranty.

Cylinder operated valves

A. Storage facility: The preferred storage

location is a clean, dry protected
warehouse. If valves are to be stored
outside, precautions should be taken to
keep valves clean and dry. Standard
packaging materials provided in valve
shipment can not be considered sufficient
for outdoor storage.

B. Equipment orientation: The preferred

orientation for optimum protection is with
the valve fully opened and the cylinder in
the vertical position. This position gives the
best support to the cylinder rod and helps
reduces the chance of a "flat spot"
developing on the cylinder seals. An
acceptable alternate position for valves
with cylinder diameters of less than 6" is
with the cylinder in the horizontal position.

C. Preparation for storage: Valves may be

stored as shipped, provided the above
Storage Facility and Equipment Orientation
instructions above are followed. If valve
packaging is altered or removed for
receiving inspection, repackage valve as
originally received.

D. Cylinder storage

These cylinder storage instructions are not
intended to replace the instructions of the
specific cylinder manufacturer and are to
be used as a guide only. If specific
instructions are required, please contact
our office.
For storage of up to 3 years; Squirt a high
quality grade of hydraulic oil or synthetic
lubricant into the cylinder ports and operate
cylinder 6-12 times on a yearly basis.
For storage 3-5 years; lubricate as above.
Additionally, extend cylinder rod until the
valve is fully closed. Coat cylinder rod with
high quality heavy grease or synthetic
lubricant. Retract cylinder rod until valve is
fully open, drawing lubricant into rod end of
cylinder. Securely plug cylinder ports with
pipe plugs, if cylinder is not pre-piped to
control accessories. If cylinder is prepiped
to accessories, plug all input and output
ports of accessories. 

E. Storage inspection: Visual inspection shall

be performed on a semiannual basis and
results recorded. Inspection as a minimum
shall include reviewing the following: 

Packaging
Flange Covers 
Dryness
Cleanliness

F. Maintenance: Maintenance shall consist of

correcting deficiencies noted during
inspection. All maintenance shall be
recorded. Contact factory prior to
performing any maintenance if valve is still
covered under warranty.

Содержание Rovalve S20

Страница 1: ...ary to use a pipe wrench or large crescent wrench to properly tighten the handwheel retaining nut Be sure to fully tighten 4 Packing assembly The packing gland bolts should be checked and adjusted to...

Страница 2: ...eel operated 4 The port flanges of the S20 2 through 24 are drilled and tapped to ANSI B16 5 150 30 and 36 are per MSS SP44 with the face to face per MSS SP81 The bolt holes in the chest or upper flan...

Страница 3: ...4 29 1 2 20 1 1 4 7 NC 4 1 2 1 30 38 3 4 33 3 4 36 28 1 1 4 7 NC 4 5 8 1 1 8 36 46 40 1 4 42 3 4 32 1 1 2 6 NC 4 5 8 1 1 8 Table C valve dimensions Valve size A B C D E F Weight 2 8 6 1 7 8 12 14 1 4...

Страница 4: ...examined and corrected as required see Figure 6 1 Valve stems extension stems and stem nut Look for excessive corrosion galling or lack of lubrication If valve stem requires lubrication utilize the g...

Страница 5: ...tool 3 Add next row alternating sides of the gate where the ends of the packing meet against each other Ends of packing must not line up If they do premature leakage could occur Complete by adding th...

Страница 6: ...can be locked in the open or closed position using the lock pin If pin style lockouts are not present the gate must be held in place to prevent unwanted movement These precautions are necessary to ke...

Страница 7: ...to be determined by customer so support best suits surrounding area It is important that the cylinder gate alignment be maintained during valve operation Supports should be designed to maintain align...

Страница 8: ...ly 1 Using pipe wrench or crescent wrench remove handwheel retaining nut from stem nut 2 Remove handwheel 3 Remove 2 or 4 retainer bolts 4 Pull retainer off 5 Rotate old stem nut until free from stem...

Страница 9: ...ation The preferred orientation for optimum protection is with the valve fully opened and the cylinder in the vertical position This position gives the best support to the cylinder rod and helps reduc...

Отзывы: