Installation and Maintenance Instructions

Tyco reserves the right to change the contents without notice

page 2

Table A maximum flange bolt torques 

(Foot pounds)

Size

Torque

5/8

55 +/-5

3/4

65 +/-5

7/8

110 +/-5

1

135 +/-5

1 1/8

150 +/-5

1 1/4

200 +/-5

1 1/2

250 +/-5

Figure 4

2. Installation instructions

Please take note of the specific installation tags provided with each valve.

1. The mating line flanges must be properly aligned prior to attempting installation. Slip on or weld

flanges can be used. Never try to make up for misaligned pipe flanges by the line bolting. Pipe
supports and/or expansion joints should be used to minimize pipe loads on valves.

2. Flange gaskets suitable for the application are required, sized to fit the raised face of the valve. 
3. The ROVALVE S20 is suitable for use in either vertical or horizontal lines. If operator is other

than vertical, additional support may be required if valve is not handwheel operated.

4. The port flanges of the S20, 2" through 24" are drilled and tapped to ANSI B16.5/150, 30" and

36" are per MSS-SP44 with the face to face per MSS-SP81. The bolt holes in the chest or
upper flange area are blind tapped, (see Figure 3).

CAUTION

Care must be taken when installing studs or bolts in the tapped holes of the flange in the
valve chest area to prevent damage. See figure 4. 

5. Cap screws or bolts that are too long can pinch the valve body, thereby forcing the body wall

into the gate, springing the gate out of line. Additional damage can occur on the gate face,
such as scoring or scratching of the gate. This type of damage normally requires the valve be
returned to our shop for repair.

6. To avoid damage, it is recommended that studs be used on all tapped bolt holes, especially the

upper chest holes. If cap screws are used, be sure that they do not enter beyond the depth of
the tapped hole when fully tightened.

Figure 3

Figure 4

Bolt holes in the chest or
upper flange area are blind
tapped

Wrong

Right

Stud with Nut

Cap Screw

Body can be deformed or fractured if flange
bolting is too long or overtorqued.

Содержание Rovalve S20

Страница 1: ...ary to use a pipe wrench or large crescent wrench to properly tighten the handwheel retaining nut Be sure to fully tighten 4 Packing assembly The packing gland bolts should be checked and adjusted to...

Страница 2: ...eel operated 4 The port flanges of the S20 2 through 24 are drilled and tapped to ANSI B16 5 150 30 and 36 are per MSS SP44 with the face to face per MSS SP81 The bolt holes in the chest or upper flan...

Страница 3: ...4 29 1 2 20 1 1 4 7 NC 4 1 2 1 30 38 3 4 33 3 4 36 28 1 1 4 7 NC 4 5 8 1 1 8 36 46 40 1 4 42 3 4 32 1 1 2 6 NC 4 5 8 1 1 8 Table C valve dimensions Valve size A B C D E F Weight 2 8 6 1 7 8 12 14 1 4...

Страница 4: ...examined and corrected as required see Figure 6 1 Valve stems extension stems and stem nut Look for excessive corrosion galling or lack of lubrication If valve stem requires lubrication utilize the g...

Страница 5: ...tool 3 Add next row alternating sides of the gate where the ends of the packing meet against each other Ends of packing must not line up If they do premature leakage could occur Complete by adding th...

Страница 6: ...can be locked in the open or closed position using the lock pin If pin style lockouts are not present the gate must be held in place to prevent unwanted movement These precautions are necessary to ke...

Страница 7: ...to be determined by customer so support best suits surrounding area It is important that the cylinder gate alignment be maintained during valve operation Supports should be designed to maintain align...

Страница 8: ...ly 1 Using pipe wrench or crescent wrench remove handwheel retaining nut from stem nut 2 Remove handwheel 3 Remove 2 or 4 retainer bolts 4 Pull retainer off 5 Rotate old stem nut until free from stem...

Страница 9: ...ation The preferred orientation for optimum protection is with the valve fully opened and the cylinder in the vertical position This position gives the best support to the cylinder rod and helps reduc...

Отзывы: