background image

TFP220

Page 3 of 8

Hazard

Type

Temperature

Bulb 

Liquid

Sprinkler Finish (See Note 5)

Natural  

Brass

Chrome 

Plated

Polyester

*

Lead  

Coated

Light

Table B describes 

UL and C-UL 

Sensitivity Rating

Table C describes 

FM 

Sensitivity Rating

Upright 

K=11.2 (TY5137)

Pendent 

K=11.2 (TY5237) 

K=14.0 (TY6237)

135°F (57°C)

Orange

1, 2, 3

**

, 4

155°F (68°C)

Red

175°F (79°C)

Yellow

200°F (93°C)

Green

1, 2, 4

1, 2, 4

286°F (141°C)

Blue

Recessed Pendent 

K=11.2 (TY5237) 

K=14.0 (TY6237) 

With Style 30 

Escutcheon

135°F (57°C)

Orange

1, 2, 3, 4

N/A

155°F (68°C)

Red

175°F (79°C)

Yellow

1, 2, 4

200°F (93°C)

Green

286°F (141°C)

Blue

Ordinary

Table B describes 

UL and C-UL 

Sensitivity Rating

Table C describes 

FM 

Sensitivity Rating

Upright 

K=11.2 (TY5137) 

K=14.0 (TY6137)

Pendent 

K=11.2 (TY5237) 

K=14.0 (TY6237)

135°F (57°C)

Orange

1, 2, 3, 4

1, 2, 3, 4

155°F (68°C)

Red

175°F (79°C)

Yellow

1, 2, 4

200°F (93°C)

Green

286°F (141°C)

Blue

Recessed Pendent 

K=11.2 (TY5237) 

K=14.0 (TY6237) 

With Style 30 or 40 

Escutcheon

135°F (57°C)

Orange

1, 2, 4

N/A

155°F (68°C)

Red

175°F (79°C)

Yellow

200°F (93°C)

Green

NOTES

1.  Listed by Underwriters Laboratories, Inc. (UL)
2.  Listed by Underwriters Laboratories, Inc., for use in Canada (C-UL)
3.  Approved by Factory Mutual Research Corporation (FM)
4.  Approved by the City of New York under MEA 177-03-E
5.  Where Polyester Coated or Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers

N/A = Not Available
* Frame and Deflector only 
** Pendent only

Area

ft x ft 

Style

Light Hazard

Ordinary Hazard

135°F 

(57°C)

155°F 

(68°C)

175°F 

(79°C)

200°F 

(93°C)

286°F 

(141°C)

135°F 

(57°C)

155°F 

(68°C)

175°F 

(79°C)

200°F 

(93°C)

286°F 

(141°C)

14 x 14 

Upright or Pendent

-

-

-

-

-

QR

QR

QR

QR

QR

Style 30 Recessed

-

-

-

-

-

QR

QR

QR

QR

QR

Style 40 Recessed

-

-

-

-

-

QR

QR

QR

QR

QR

16 x 16

Upright or Pendent

QR*

QR*

QR*

QR*

QR*

SR

SR

SR

SR

SR

Style 30 Recessed

QR*

QR*

QR*

QR*

QR*

SR

SR

SR

SR

SR

Style 40 Recessed

N/A

N/A

N/A

N/A

N/A

SR

SR

SR

SR

SR

18 x 18

Upright or Pendent

QR*

QR*

QR*

QR*

QR*

SR

SR

SR

SR

SR

Style 30 Recessed

QR*

QR*

QR*

QR*

QR*

SR

SR

SR

SR

SR

Style 40 Recessed

N/A

N/A

N/A

N/A

N/A

SR

SR

SR

SR

SR

20 x 20

Upright or Pendent

QR*

QR*

QR*

SR*

SR*

SR

SR

SR

SR

SR

Style 30 Recessed

QR*

QR*

QR*

SR*

SR*

SR

SR

SR

SR

SR

Style 40 Recessed

N/A

N/A

N/A

N/A

N/A

SR

SR

SR

SR

SR

NOTES

•  QR = Quick Response 
•  SR = Standard Response
•  N/A = Not Applicable

* Does not apply to Upright K=14.0

TABLE A 

LABORATORY LISTINGS AND APPROVALS

TABLE B 

SENSITIVITY RATING FOR UL AND C-UL LISTING OF SERIES EC-11 OR EC-14 SPRINKLERS 

(REFER TO TABLE D FOR PERMITTED K-FACTOR/AREA COMBINATIONS)

Содержание EC-11 Series

Страница 1: ...s beyond that which occurs when exposed to corrosive atmospheres Although corrosion resistant coated sprinklers passed standard corrosion tests of the applicable approval agencies this testing is not...

Страница 2: ...ed by NFPA 13 for example Unobstructed combustible or noncombustible ceiling con struction with a deflector to ceiling roof deck distance of 1 to 12 in 25 to 300 mm Obstructed non combusti ble ceiling...

Страница 3: ...ory Mutual Research Corporation FM 4 Approved by the City of New York under MEA 177 03 E 5 Where Polyester Coated or Lead Coated Sprinklers are noted to be UL and C UL Listed the sprinklers are UL and...

Страница 4: ...14 0 EC Pendent or Upright Quick 10 20 100 400 Up to 30 Noncombustible Unobstructed Noncombustible Obstructed or Combustible Unobstructed 11 2 EC 14 0 EC Pendent Recessed Style 30 10 20 100 400 Up to...

Страница 5: ...er or over tightening the Sprinkler Re adjust the position of the sprinkler fitting to suit Step 1 Install the sprinkler with the deflector parallel to the mounting surface Install pendent sprinklers...

Страница 6: ...0 MALLEABLE IRON REDUCING SPRINKLER FITTING FITTING SIDE TOWARDS SPRINKLER FITTING WRENCH RECESS END A WRENCH RECESS WRENCH HEX 1 4 6 4 mm 1 2 12 7 mm MOUNTING SURFACE FACE OF SPRINKLER FITTING 1 2 1...

Страница 7: ...y the corrosive conditions present The owner is responsible for the inspection testing and maintenance of their fire protection system and devices in compliance with this doc ument as well as with the...

Страница 8: ...e Protection Association TEFLON is a registered trademark of DuPont 1400 Pennbrook Parkway Lansdale PA 19446 Telephone 1 215 362 0700 2019 Johnson Controls All rights reserved All specifications and o...

Отзывы: