Internet Alarm Communicator Installation Manual

      

NOTE: 

 For additional details:

• Refer to section [983] for troubleshooting the firmware updates
• Refer to section [984] to verify the trouble status  

C

OMMUNICATOR

 T

ROUBLESHOOTING

Table 6:     Trouble indications

Trouble 

indication

Trouble 

Indicator 

Digit

Possible 

Causes

Trouble Possible Solution

No Indication

N/A

No Power

• Check the power connections between the panel and the communicator.

• Confirm PC-LINK cable is properly installed between communicator and

panel.

Trouble LED – 

2 Flashes

02

Panel 

Supervision 

Trouble

• Check section [382] toggle option [5] is ON (Alternate Communicator

Enabled).

• Ensure the PC-LINK cable between the panel and communicator is connected

properly (not reversed) and is securely in place.

Yellow LED – 

6 Flashes

06

Ethernet 

Trouble

• Check with your ISP to confirm Internet service is active in your area.

• Ensure your Ethernet cable is securely inserted into the RJ45 jack of the com-

municator and the hub/router/switch.

• Check the link light on the hub/router/switch is ON. If link light is OFF, start the

hub/router/switch. 

• If DHCP is used, ensure that the unit has an assigned IP address from the server.

In Section [851] [992] verify a valid IP address is programmed. If not, contact

the network administrator.

• If problem persists, replace the Ethernet cable and RJ45 connector.

Yellow LED – 

7 Flashes

07

Receiver Not 

Available

• Ensure that the Ethernet path has Internet connectivity.

• If using a static IP address, confirm that the gateway and subnet mask are

entered correctly.

• If the network has a firewall, ensure the network has the programmed 

outgoing ports open (default UDP port 3060 and port 3065).

• Ensure that all the receivers are programmed for DHCP or have the proper IP

address and port number.

Yellow LED – 

8 Flashes

08

Receiver 

Supervision 

Trouble

• This trouble is indicated when supervision is enabled and the unit is not able to

successfully communicate with the receiver.

• If this trouble persists, contact your central station.

Yellow LED - 

9 Flashes

09

 FTC Trouble

• The unit has exhausted all communications attempts to all programmed receiv-

ers for events generated by the communicator.

• Restart the system, if trouble persists, contact your dealer.

Yellow LED – 

12 Flashes

0C

Module 

Configuration 

Trouble

• This indication appears when section [021] system account code or 

sections [101] or [111] receiver account code have not been programmed.

Ensure that a valid account code has been entered in these sections.

 Red and Yellow 

LEDs flashing 

together

N/A

Initialization 

Sequence

• The unit is still initializing please wait while the unit establishes a connection to

all programmed receivers. 

Note: This process may take several minutes to complete.

Boot Loader 

Failed

• If the initialization sequence is taking more than several minutes, the boot

loader might have failed.

• Confirm that the boot loader has failed by entering communicator program-

ming [*][8][installer code][851].

• If access is granted, continue waiting for the initialization sequence to complete.

•  If access is denied (long error tone), disconnect power from, then reconnect

power to the communicator module.

firealarmresources.com

Содержание DSC TL280

Страница 1: ...cator North America INSTALLATION MANUAL V4 0 Warning This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufa...

Страница 2: ...firealarmresources com...

Страница 3: ...or Troubleshooting 14 Ethernet Programming Options 15 System Options 15 Communications Reporting Codes 24 Ethernet Receiver 1 Options 25 Ethernet Receiver 2 Options 26 Ethernet Options 27 Receiver Dia...

Страница 4: ...their belongings Motion Detectors Motion detectors can only detect motion within the designated areas as shown in their respective installation instructions They cannot discriminate between intruders...

Страница 5: ...ssories only with this equipment Do not stay close to the equipment during device operation Model Information This manual covers the following alarm communicator models TL280 and TL280R Models end ing...

Страница 6: ...each channel is independent The communicator can also be used as an active communication system with the security levels A1 A4 each channel independent For active line security systems AES128 bit enc...

Страница 7: ...cording to the local electrical codes The communicator shall be installed by service persons only service person is defined as a person having the appropriate technical training and experience necessa...

Страница 8: ...ls only When installing the communicator for use with 3rd party applications an RS 422 cable must be connected between the 3rd party device and the communicator module NOTE Maximum cable length for RS...

Страница 9: ...nel perform the following steps See Figure 3 a Disconnect both AC power and battery connections from the panel and disconnect tele phone line 4 Install the RS 422 connections R models only If using th...

Страница 10: ...ted systems Keypad Data Display Section Toggle Options The number is displayed when toggle is ON the number is not dis played when toggle is OFF e g toggle options displays 3 6 Options 3 and 6 are ON...

Страница 11: ...session through Ethernet NOTE Before leaving the premises the installer should verify all programmed communications paths See programming options section 851 901 to send immediate test transmissions N...

Страница 12: ...ed on receipt of first poll from the panel Ethernet Trouble 6 Flashes This trouble is indicated when Ethernet link between the transmitter and the local switch or router is absent This trouble will al...

Страница 13: ...hort the hardware default pins 4 and 5 4 Remove AC and DC power from the panel and then reapply power to the panel 5 Wait 30 seconds 6 Remove the jumper from the hardware default pins 4 and 5 green LE...

Страница 14: ...confirm that the gateway and subnet mask are entered correctly If the network has a firewall ensure the network has the programmed outgoing ports open default UDP port 3060 and port 3065 Ensure that a...

Страница 15: ...elds each field is 3 digits Valid range 000 255 NOTE If DHCP is enabled the DHCP server will assign the subnet mask for this section and the programmed value will be ignored 003 Ethernet Gateway IP Ad...

Страница 16: ...red to meet the approval for the installation OFF Events will be communicated to the receivers individually Toggle should be OFF when guaranteed message delivery to both receivers is required 4 Reserv...

Страница 17: ...l assign this value If an address is programmed and DHCP is used the address that you program will be used instead of the DHCP address Programming Options 010 System Toggle Options 3 1 Reserved 2 Visu...

Страница 18: ...ue for your Time Zone Valid range is 00 FF Table 8 World Wide Time Zones HEX Value Offset Hours Std Abbrev Location 01 12 BIT Baker Island Time 05 11 NUT Niue Time SST Somoa Standard Time 09 10 HAST H...

Страница 19: ...zilia Time UYT Uruguay Standard Time SRT Suriname Time ROTT Rothera Time PMST St Pierre Miquelon Standard Time GFT French Guiana Time 29 2 GST South Georgia and the South Sandwich Islands BEST Brazil...

Страница 20: ...ime SCT Seychelles Time GST Gulf Standard Time SAMT Samara Time RET Reunion Time MUT Mauritius Time ICT Iles Crozet Time GET Georgia Standard Time AZT Azerbaijan Time 43 4 5 AFT Afghanistan Time 45 5...

Страница 21: ...Time KRAT Krasnoyarsk Time WIB Waktu Indonesia Bagian Barat ICT Indochina Time BDT Bangladesh Standard Time 51 8 AWST Australian Western Standard Time CST China Standard Time HKST Hong Kong Standard T...

Страница 22: ...9 10 AEST Australian Eastern Standard Time GST Guam Standard Time YAPT Yap Time VLAT Vladivostok Time TRUT Truk Time PGT Papua New Guinea Time DTAT District de Terre Adelie Time ChST Chamorro Standard...

Страница 23: ...e configured to send Events in SIA or CID format The SIA communication format follows the level 2 specifications of the SIA Digital Communication Standard October 1997 This format will send the accoun...

Страница 24: ...test transmission can be enabled or disabled in section 005 toggle option 7 Alternating Test Transmission with backup receivers Set Ethernet section 026 to FF 027 to 00 Interval 1 If the test transmi...

Страница 25: ...nly if the panel becomes offline after a remote firmware update session has started 095 SA Incoming Local Port Default 0000 096 SA Outgoing Local Port Default 0000 097 SA Call Up IP Default 000 000 00...

Страница 26: ...transmitters The account code is used when transmitting heartbeat signals to the central station receiver Signals received from the control panel will use the control panel account number Valid range...

Страница 27: ...nge 000000 999999 minutes Once the unit has sent the initial periodic test transmission all future test trans missions will be offset by the programmed number of minutes See sections 026 029 NOTE Mini...

Страница 28: ...re update process 25 System update pending communication in progress Retry in a few minutes if issue persists contact DSC Tech Support Firmware Update Sequence Change A0 System firmware update success...

Страница 29: ...ed for DHCP and you need to see the IP address was assigned to the device by the DHCP Server This value is programmed in Section 007 or assigned by DHCP 989 DNS 2 IP Address This section will display...

Страница 30: ...ler to refresh the unit after changes and also return the com municator to the default state 00 Default Module All programming sections in module revert to factory settings This will erase all existin...

Страница 31: ...ng Options 010 System Toggle Options 3 ____ 1 Reserved ____ 2 Visual Verification Default OFF ____ 3 Reserved 011 Installer Code Default CAFE Valid range 0000 FFFF ____ ____ ____ ____ 012 DLS Incoming...

Страница 32: ...r 1 UDP Local Port Default 0BF4 3060 Valid range 0000 FFFF ____ ____ ____ ____ 106 Ethernet Receiver 1 Domain Name Default 32 ASCII characters Programming not permitted on UL ULC listed system _______...

Страница 33: ..._ ____ ____ ____ ____ ____ 991 Firmware Version ____ ____ ____ ____ ____ ____ ____ ____ 992 Ethernet IP Address ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ 993 Ethernet Gateway Address...

Страница 34: ...d in such a manner as to adversely affect performance or prevent adequate inspection or testing to verify any warranty claim Access cards or tags returned for replacement under warranty will be credit...

Страница 35: ...des and this EULA and provided the recipient agrees to the terms of this EULA If the SOFTWARE PRODUCT is an upgrade any transfer must also include all prior versions of the SOFTWARE PRODUCT Terminatio...

Страница 36: ...onsult the dealer or an experienced radio television techni cian for help The user may find the following booklet prepared by the FCC useful How to Identify and Resolve Radio Television Interfer ence...

Отзывы: