2.2. Enrollment

Refer to the BW panel's Installer's Guide and follow the procedure under the

"02:ZONES/DEVICES"

option of the Installer Menu. A general description

of the procedure is provided in the following flow chart.

Step 1

Step 2

Step 3

Step 4

Step 5

Enter the Installer menu
and select

“02:ZONES/DEVICES”

Select

"ADD NEW

DEVICE"

See Note 1

Enroll the device or enter
the device ID

Select the desired siren
number for the new siren

Configure Location and
Zone Type Parameters

02:ZONES/DEVICES

ð

ADD NEW DEVICES.

6

MODIFY DEVICES

ð

ENROLL NOW or
ENTR ID:XXX-XXXX

ð

SR1:Siren Outdoor
ID No.410-XXXX

ð

SR1.LOCATION
SR1.ZONE TYPE
SR1.SET CHIME

ð

Step 6

Step 7

Step 8

Notes:

Enter PARTITIONS.
See Note 2

Assign partitions to the siren

by pressing the

,

and

buttons

on the panel

Select the "DEV
SETTINGS" option and
refer to the section below to
configure the siren
parameters.

1.

If the siren is already enrolled, you can
configure the siren parameters and assign
partitions via the

“Modify Devices”

option – see Step 2.

2.

PARTITIONS will appear only if
PARTITIONING was previously enabled in
a panel that supports the Partitioning
feature (for further details, see
"Partitioning" in the BW Installer Guide).

3.

When there is an alarm, the siren will
sound regardless of partition assignment.

SR1.PARTITIONS

ð

SR1:P1

n

--

P2 ....P3

n

ð

SR1:DEV SETTINGS

ð

ð

means scroll

ww

and select

OK

2.3. Configuring the Siren Parameters

Enter the

DEVICE SETTINGS

menu and follow the configuration instructions for the BW-SRO outdoor siren as described in the following table.

Option

Configuration Instructions

STROBE ALARM

Here you determine whether or not to activate the strobe alarm, and if activated, whether to activate the strobe until the alarm
system is disarmed, or, for the programmed period of time (see "Siren Configuration" section in the control panel Installer
Guide).

Optional settings:

Timer limited

(default),

Disabled

and

Until Disarmed

EXIT-ENTRY Beeps

Here you determine whether or not to activate the exit – entry beeps, and if enabled, whether to activate in HOME or AWAY
mode.

Optional settings:

Disabled

(default),

Disabled & Home

and

Enabled

.

SQUAWK

Here you determine whether or not to enable the squawk, and if enabled, whether to activate the sounder only, or, the
sounder and strobe simultaneously.

Optional settings:

Disabled

(default),

Sounder only

,

Strobe only

and

strobe

.

SOUNDER
VOLUME

Here you determine the volume level of the sounder.

Optional settings:

Volume HIGH

(default),

Volume LOW

and

Volume MID

.

ACTIVITY LED

Here you determine whether or not the LED will be activated to indicate that the siren is operating.

Optional settings:

Disabled

(default) and

Enabled

.

AUTO TAMPER
ALRM

Here you determine whether or not the siren alone will sound a tamper alarm when there is no communication between the
siren and the control panel.

Optional settings:

Disabled

(default) and

Enabled

.

FRZR TRBL BEEP

Turn on or turn off freezer trouble beeps for indoor or outdoor sirens. Freezer trouble beeps occur every minute.

Optional settings:

on

(default) and

off

.

D-308696 BW-SRO Installation Guide