4.0 Hardware Descriptions and Specifications
- 33 -
Flashes/Color
Error
4Yellow
Computer buffer full
5/Yellow
Checksum failed when downloading flash ROM files.
2/Green
SD Card is90% full
5/Green
SD Card ID Mismatch - Mismatch occurs when an SD card is not formatted using the Console or the SD card is inserted into the
wrong DRL5-IP. To resolve this, either format the SD card or Re-ID the SD card using the Console. Please refer to the SG-Systems
Console Manual for more detailed instructions.
4.3.2.1 Network Fault
When this problem occurs, the following information is transmitted to the printer and automation.
Printer:
SG -01-001-0000-NR-Network Failure
Automation:
001001[#0000|NNT*IP.IP.IP.IP*]
When this problem restores, the following information is transmitted to the printer and automation:
Printer:
SG -01-001-0000-NR-Network Restoral
Automation:
001001[#0000|NNR*IP.IP.IP.IP*]
4.3.2.2 Invalid Report Condition
When this problem is encountered, the following information is transmitted to the printer and automation:
Printer:
SG-12-234-AAAAAA-YN-*Invalid Report 192.158.8.34*
Automation:
012234[#AAAAAA¦NYN*192.158.8.34*]
The output for account code 'AAAAAA' indicates that data has been received but is not valid (e.g.,the packet is encrypted and the SG-DRL5-IP does
not have the proper key) or the T-LINK transmitter packet was rejected (NAK) four times by the receiver.
4.3.2.3 SG-CPM5 Absent
If the line card cannot detect the SG-CPM5 polling, it starts buffering incoming calls (depending on option [123] Busy Out). Up to 2500 alarm mes-
sages for the printer and computer are retained in the line card event buffer. When the event buffer is full, the line card stops answering calls and the
status LED flashes to indicate busy out. When the SG-CPM5 error condition is corrected, alarm messages in the event buffer are transmitted to the SG-
CPM5 with the corresponding time/date the alarm was received.
4.3.2.4 Ethernet Interface
The SG-DRL5-IP has an Ethernet interface which operates as a 10BaseT/100BaseT/1000BaseT. This port is accessible via a standard RJ45 connector.
The IP address of the SG-DRL5-IP is programmable. The Ethernet port is used for transmitter communications.
The Ethernet communication lines must be connected first to an approved (acceptable to the local authorities) type NID (Network Interface Device)
before leaving the premises (e.g., UL installations, UL60950 Listed NID).
4.3.2.5 Supervised Receiver Database
The receiver has the capability of monitoring IP transmitters set up as supervised units. It automatically keeps track of new transmitters and indicates
when one has been lost.
Transmitters restore differently depending on type. Older transmitters, such as the TL-250, must receive two heartbeats within the Transmitter Restoral
Debounce time window (Option [222]) and one heartbeat after the window has expired within the Transmitter Absent Debounce time (Option [221]).
When a heartbeat is received after the Restoral window, an event is transmitted to the printer and automation. Newer transmitters, such as the TL2803G
or the 3G4000, restore immediately after receiving a second heartbeat within the programmed window.
Restoral:
Printer:
SG -00-001-XXXXXXXXXXYK-*Transmitter Restoral IP.IP.IP.IP*
Automation:
000001[#XXXXXXXXXX|NYK*IP.IP.IP.IP*]
Failure:
Printer:
SG -00-001-XXXXXXXXXXYC-*Transmitter Failure IP.IP.IP.IP*
Automation:
000001[#XXXXXXXXXX|NYC*IP.IP.IP.IP*]
NOTE: Newer DSC transmitters will only transmit a heartbeat after the last transmission, whereas the older transmitters will transmit a
heartbeat at the programmed amount of time regardless of the alarm traffic.
NOTE: Transmitter Restore Time must be 30 seconds minimum.
NOTE: For UL Listed products, the permitted setting is 90 seconds.
NOTE: Two heartbeats must be received from the supervised IP transmitter before the register and restoral of the communicator.
S
G
-S
ys
te
m
5
O
pe
ra
ti
ng
M
anua
l
Содержание SG-System 5
Страница 68: ...6 0 Options 68 Automation Mode Diagrams FIGURE 6 1 Flow Diagram for Loop Mode 0 SG System 5 Operating Manual ...
Страница 69: ...6 0 Options 69 FIGURE 6 2 Flow Diagram for Fallback Mode 1 SG System 5 Operating Manual ...
Страница 70: ...6 0 Options 70 FIGURE 6 3 Flow Diagram for All Mode 2 SG System 5 Operating Manual ...
Страница 71: ...6 0 Options 71 FIGURE 6 4 Flow Diagram for IP Fallback Mode 3 SG System 5 Operating Manual ...