background image

Illustra Flex 3MP and 8MP Indoor Box Quick Start Guide

8200-1456-04 G0

18

Table 13 Flex 8MP Box Camera resolutions

Flex 8MP Box camera resolutions

Stream 1

FPS

Stream 2

FPS

Stream 3

FPS

(3840x2160) 4K 16:9

1-15

(1280x720) 720p

1-15 or 1-30

(640x360) nHD 16:9

7-15

(3264x1840) 16:9

(1024x576) PAL+ 16:9

(480x360) 480 4:3

(2592x1944) 4:3

(640x360) nHD 16:9

(384x288) 4:3

(2688x1520) 16:9

(480x360) 480 4:3

(2048x1536) QXGA 4:3

(384x288) 4:3

(1920x1080) 1080p 16:9

1-60

(1280x960) SXGA 16:9

(1280X720) 720p 16:9

Note:Stream 2

is limited to a maximum of 15 FPS when: Stream 1 is set to

2048x1536

or above.

Stream 1 is set to

1920x1080

or above with FPS greater that 30.

Note:Stream 2

automatically reconfigures to a maximum of 15 FPS if Stream 1 FPS is 30 or greater.

Note:Stream 2

supports 1-30 FPS when Stream 1 is set to 1920x1080 or below with FPS set to a

maximum of 30.

Note:Codec MJPEG

is not supported when the resolution is equal to or greater than 2048x1536.

Note:TrueWDR 2x

. When TrueWDR2x is switch on, the following limits apply: For 2048x1536 and

above, the framerate is limited to 15FPS (as it is when TrueWDR is off). For 1920x1080 and below,
the framerate is limited to 30FPS.

Note:TrueWDR 3x

is not available on 8MP units.

Содержание Illustra Flex 3MP Box

Страница 1: ...Illustra Flex Series 3MP and 8MP Box Cameras Quick Start Guide...

Страница 2: ...you need service or support Our dealers are empowered to provide the very best in customer service and support Dealers should contact American Tyco Security Products at 800 507 6268 or 561 912 6259 or...

Страница 3: ...1 Product Features 1 Product overview 1 Installation 4 System Requirements 6 Network Connection 7 Default IP Address 7 DHCP 8 Managing cameras with the Illustra Connect tool 9 Network Topology 12 App...

Страница 4: ...or ITE NEC Class 2 or LPS with a rating of 24VAC 550mA minimum and 50 degrees Celsius Video Out connection should be intra building only Avoid aligning the lens to very bright objects for example ligh...

Страница 5: ...Illustra Flex Mini Domes select Documents select Application Notes and select Bubble Handling and Cleaning Procedures Product overview This chapter explains the features and installation of the Illus...

Страница 6: ...x 3MP and 8MP Indoor Box Quick Start Guide 8200 1456 04 G0 2 Camera connectors Figure 3 on page 2 and Connector descriptions describe the connectors of the camera and their designations Figure 3 Camer...

Страница 7: ...ard Slot To use a Micro SD card for recording and storage 5 Reset Button To reboot the unit 6 Default Button To reset all settings of the unit to factory default press for 5 seconds 7 Auto Focus Butto...

Страница 8: ...Screwdriver Wire cutters Checking appearance When first taking the camera out of the box check if there is any visible damage to the appearance of the unit and its accessories The protective material...

Страница 9: ...a unit to a pendant mount not supplied and insert and tighten the screws on the tripod receptacle into the screw holes on the base 2 Mount the camera unit onto the ceiling or wall and fasten securely...

Страница 10: ...er Microsoft Internet Explorer 9 or above Firefox Safari Chrome Unit Power Supply DC 12V AC 24V PoE Networking Wired 10 100BASE T Ethernet RJ 45 connector NOTE A switch is required for surveillance on...

Страница 11: ...abled the camera first reboots for approximately 30 seconds and then remains accessible at its Static IP until it connects to a DHCP server Connect to a PC directly Directly connect the camera to a PC...

Страница 12: ...P Step Action 1 Select Setup on the Web User Interface banner to display the setup menus 2 Select the TCP IP tab in the Basic Configuration menu 3 Select the Enable DHCP check box to enable DHCP and d...

Страница 13: ...eras on the LAN It can help you find multiple network cameras set the IP addresses show connection status manage firmware upgrades bulk configuration Procedure 6 Connecting to the camera using Illustr...

Страница 14: ...me is admin 3 Enter the password in the Password text box The default password is admin 4 Select Log in Note The first time that you access the camera or after a factory reset the following two pop up...

Страница 15: ...illustracameras com for supported lens models details Procedure 10 Perform a Lens Selection Step Action 1 Select Setup on the Web Interface Banner to display the setup menus 2 Select Picture Settings...

Страница 16: ...deliver video images and audio in real time using the Internet and Intranet It is equipped with an Ethernet RJ 45 network interface The following images illustrate the network topology of the cameras...

Страница 17: ...ng Material Aluminum Alloy Other Housing Material PC ABS Video Processor ROM Flash Size 256 Mbytes RAM Size 512 Mbytes RTC Hold Up Time 24 hours Image Sensor Format 1 2 8 CMOS Capture Method Rolling S...

Страница 18: ...boot and Return to Defaults Environmental Operating Temperature Range 20 50 C Start up Temperature Range 20 50 C Water Dust Intrusion N A Client Interfaces Browsers supported IE 9 or above Firefox Saf...

Страница 19: ...c IP address LLDP Time Synchronization NTP RFC1305 IETF NTP Working Group i minute poll rate E mail SMTP RFC5321 Authenticated SMTP RFC4954 Authentication and Security IEEE 802 1x TLS PEAP HTTPS HTTP...

Страница 20: ...ps Stream Resolution Codecs Frame Rates fps Stream Resolution Codecs Frame Rates fps TWDR Support Stream 1 Stream 2 Stream 3 2048x1536 H264 H264 IntelliZip H265 H26 IntelliZip 1 30 1280x720 H264 H264...

Страница 21: ...64 H264 IntelliZip H265 H26 IntelliZip MJPEG 1 15 480x360 MJPEG 7 15 No 1280x720 H264 H264 IntelliZip H265 H26 IntelliZip MJPEG 31 60 640x360 H264 H264 IntelliZip H265 H26 IntelliZip MJPEG 1 15 384x28...

Страница 22: ...imited to a maximum of 15 FPS when Stream 1 is set to 2048x1536 or above Stream 1 is set to 1920x1080 or above with FPS greater that 30 Note Stream 2 automatically reconfigures to a maximum of 15 FPS...

Отзывы: