background image

1

2

" Orifice

Horizontal
Sidewall
Automatic
Sprinkler

Omega 

HEC-12EC PRO

Prohibitor

TM

Product
Description

occupancies in accordance with
current NFPA 13 Standards (for
up to 16' x 20' coverages).

For all models of Prohibitor

TM

Sprinklers, an optional 3

5

8

" diameter

light gauge escutcheon closure plate is
available, for use where the wall
penetration is greater than the
recommended 2

1

4

" diameter.  The

escutcheon closure plate fits between
the base of the escutcheon and the
mounting surface.

For all models of Prohibitor

TM

Sprinklers, an optional 4

1

2

" diameter

1

8

" thick security closure plate  is

available for use where additional
security is a consideration.  The
security closure greatly reduces the
possibility of inserting a tool, prybar or
other device behind the sprinkler.  The
security closure plate fits between the
base of the escutcheon and the
mounting surface.

For all models of Prohibitor

TM

Sprinklers, the optional Ident-A-Fire

TM

feature is available to provide an alarm
signal upon activation of the sprinkler.

Prohibitor

TM

 Sprinklers are available

in two standard finishes, brass and
chrome plated.  Their mating
escutcheon is available in three
standard finishes, brass, chrome plated
and white painted, with additional
special finishes available.
   Operation:  A fusible alloy pellet is
compressed with a bearing disc into a
copper housing by a ball plunger. Heat
is absorbed by the heat collecting fins
and conducted to the alloy pellet.  At
the rated temperature the alloy melts,
causing the ball plunger to drop,
freeing balls from the retaining groove.
This movement allows system water
pressure to force the orifice sealing
mechanism and deflector assembly
open. Water is then discharged in a
designed flow pattern.

The Omega Prohibitor

TM

 Model HEC-

12EC PRO Automatic Sprinklers have
been specifically designed for use in
institutional occupancies, such as
correctional facilities and mental health
facilities, where the occupants may
attempt to tamper with or otherwise
employ the sprinkler to injure
themselves or others.

The horizontal sidewall style

Prohibitor

TM

 HEC-12EC PRO sprinklers

are recessed into the mounting surface
with only a portion of the heat
collecting fin assembly projecting into
the protected space.  The heat
collecting assembly has an average
breakaway load of 68 lbs., and a
maximum breakaway load of 85 lbs.
Unlike other institutional sprinklers, the
escutcheon plate and optional closure
plates are firmly attached to the
recessed sprinkler body with tamper
resistant retaining screws.

The Omega Prohibitor

TM

 sprinklers

are designed with an aesthetically
pleasing, low  profile silhouette.  They
feature a spray pattern that has been
shown to be effective in the control or
extinguishment of fire.

 The Model HEC-12EC PRO carries

two separate Listings* by Underwriter's
Laboratories for use as:

1.  An Extended Coverage Quick

Response Sprinkler that qualifies
for installation at 4"-12" below the
ceiling in light hazard occupancies
in accordance with current NFPA
13 Standards (for up to 16' x 18'
coverages.

2.  An Extended Coverage Sprinkler

that qualifies for installation 4"-6"
below the ceiling in light hazard

Manufactured by: Central Sprinkler Company
451 North Cannon Avenue, Lansdale, Pennsylvania 19446

Extended Coverage Quick Response (16'x18')
Extended Coverage (16'x20')
Institutional Sidewall Automatic Sprinkler

11-94

No. 1-10.0

HEC-12 EC PRO

OBSOLETE

Содержание CENTRAL Omega HEC-12EC PRO

Страница 1: ...r pressure to force the orifice sealing mechanism and deflector assembly open Water is then discharged in a designed flow pattern The Omega ProhibitorTM Model HEC 12EC PRO Automatic Sprinklers have been specifically designed for use in institutional occupancies such as correctional facilities and mental health facilities where the occupants may attempt to tamper with or otherwise employ the sprink...

Страница 2: ...w 1 2 1 4 1 16 3 4 2 3 4 3 8 A 2 1 4 Dia Hole in Wall 2 1 2 Escutcheon 4 1 2 Dia Security Closure Plate 3 5 8 Dia Escutcheon Closure Plate 1 7 16 1 16 No Closure Plate 1 3 8 1 16 Escutcheon Closure Plate 1 5 16 1 16 Security Closure Plate Note The special tamper proof socket must be used for installation or removal of the tamper resistant retaining screws Rigid Support Collar with Bolt Part 162 01...

Страница 3: ...brass chrome plated white painted Security Closure Plate chrome plated brass plated white painted Length 23 8 60 3 mm Width 2 50 8 mm Weight 6 8 oz 193 grams ProhibitorTM sprinklers must be installed in accordance with current NFPA 13 Deviations from these requirements and standards or any alteration to the sprinkler itself will void any warranty made by Central Sprinkler Company In addition insta...

Страница 4: ...ket Caution Special care must be taken when installing with a CPVC system Sprinklers must be installed after the manufacturer s recommended setting time for the primer and cement to ensure that neither accumulate within the sprinkler Special care must be taken when installing with a copper system Sprinklers must be installed only after the inside of the sprinkler nipple and associated fittings hav...

Отзывы: