Страница 2: ...3 4 Operation 4 5 Accessories and Replacement Parts 5 6 Technical Specifications 5 Section Title Page Raychem Interconnect a division of Tyco Electronics International Ltd Printed in USA No TUS 44 33...
Страница 3: ...nual Incorrect use of the AA 400 Mark IV can cause serious injury This equipment must be operated and maintained only by fully trained and qualified personnel Failure to follow the manufacturer s inst...
Страница 4: ...Avoid aiming the heat gun nozzle s hot air stream at the unit s hose power cord or control unit Before disconnecting the operating AA 400 Mark IV air supply first allow the heating element to cool Fa...
Страница 5: ...eating The green HEAT ON indicator light is illuminated whenever power is applied to the heating element This light goes off when the pressure switch cuts off power to the element Step 4 Within 30 sec...
Страница 6: ...away from the device The hot air stream should be directed at the solder band Closer placement of the nozzle tip can result in browning of the tubing or spurting of the melted solder Step 6 The needle...
Страница 7: ...ION 6 TECHNICAL SPECIFICATIONS Power supply 240 Vac 2A 50 60 Hz Power consumption 363 watts Fuses 2 x 2A 5 x 20 mm Power supply cable length 2 meters Lamp 240 Vac green Air connection requirements 1 4...