background image

6

3.3.3

Install the mounting brackets on the correct position. Respect

correct orientation.

3.3.4

Place the top cover back on the shelf. 

3.3.5

Determine the position of the shelf (see rack installation

instruction). Fix the cage nuts into the

rack. Mount the shelf using the FACC-ALLEN key.

3.4

Termination of loose tube cable

3.4.1

Open the drawer to the fully open position. Strip the cable

approx 1.8m. Cut the strength member approx 100mm. Feed the cable

through the flex tube.

3.4.3

Put FOSC-400AA tray in place. Cut 4 pieces of spiral tube

200mm. Put foam at the ends of the spiral tubes.

3.4.4

Strip LT ( loose tube ) over 1.1meter starting at 170mm after

end of flex tube.

3.4.2

Fasten cable with push T-wraps and put strength member in

strength member connector. Use foam there where the cable is fixed.

3.4.5

Put foam at the end of the LT. Fasten the LT together with

spiral tube with two T-wraps. Always put the LT to the outside of the

FOSC tray. Route the primary coated fiber on the FOSC tray.

3.4.6

Fasten the second spiral tube to the FOSC-tray.

In case of 19 inch. (standard)

In case of ETSI

Termination at the back

Содержание FOMS-FSP-O Series

Страница 1: ...g 3 8 Closing the shelf Contents 1 Introduction The FOMS FPS O shelf is a mechanical enclosure for a physical fiber management system It is used for splicing and connector patching depending on type u...

Страница 2: ...Velcro Cage nuts and bolts for mounting Back cable termination kit 2 3 Tools FACC ALLEN KEY 5 350 to mount shelf in rack marker pen Philips screwdriver FACC CAGE NUT TOOL for easy installation of cag...

Страница 3: ...the mounting brackets on the correct position Respect correct orientation 3 1 4 Place the top cover back on the shelf 3 1 5 Determine the position of the shelf see rack installation instruction Fix t...

Страница 4: ...ctor adaptors in the patchpanel In the picture you also can see the blind stops 3 2 2 Slide the drawer to the fully open position 3 2 3 Entering the shelf trough the trumpet 3 2 4 Remove the velcro Gu...

Страница 5: ...t is not recommended to remove the velcro totally 3 3 Preparation of the shelf in case of splice patch LT cable 3 3 1 Remove top cover place strength member connector in case of loose tube 3 3 2 Prepa...

Страница 6: ...ough the flex tube 3 4 3 Put FOSC 400AA tray in place Cut 4 pieces of spiral tube 200mm Put foam at the ends of the spiral tubes 3 4 4 Strip LT loose tube over 1 1meter starting at 170mm after end of...

Страница 7: ...d connect the pigtails 3 4 11 Termination of cable in the rack entering the shelf from the side also possible entering at the back Next step see 3 4 3 3 5 Termination of IFC cable trumpet optional 3 4...

Страница 8: ...3 5 2 Termination up to the tray fixation together with the spiral tube Check the positions of the spiral tubes 3 5 3 Back termination of the IFC cable routing inside the shelf is the same as the pre...

Страница 9: ...ors of type SMOUV 1120 02 length 45 mm installed outer diameter is 2 4 mm or equivalent After each splice is made the splice should be stored as indicated on the drawing First protector in position 1...

Страница 10: ...cing 3 8 Closing the shelf 3 8 1 Mount the guiding snap onto the shelf Patch the outgoing jumpers and guide them through the guiding snap 3 8 2 Additionally a plastic cover with label can be placed to...

Страница 11: ...11...

Страница 12: ...eved to be reliable However Tyco Electronics makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use Tyco Electronics obligations shall only be as...

Отзывы: