408- 9085
Terminating Head 58062- 1
3
of 5
Rev
B
Tyco Electronics Corporation
Figure 4
Top of Wire Conductor Below
Top of Wire Barrel Slot
Top of Wire
Barrel Slot
Correct
Acceptable
Termination Inspection
Incorrect
Wire Was Not Inserted
Deep Enough During
Termination
Wire Was Not Inserted
Straight Before
Termination
Wire Was Not Fully
Inserted Before
Termination
Wire Was Inserted With
Too Much Force During
Termination
Damaged Housing—
Connector Was Too
Tight or Too Loose in
Head During Termination
A
A
0.51
[.020]
Min
Section A--A
Arms of Insulation Support
Barrel Partially Closed
Arms of Insulation Support
Barrel Completely Closed
AMPMODU MT
Receptacle Connector
B. Manual and Electric Power Units
1. Remove the head from the power unit according
to the instructions packaged with the power unit.
Make sure to observe any cautions and dangers.
2. Turn the adjuster one--sixth of a revolution
clockwise
if the wire is too deep in the contact, and
counterclockwise
if the wire is not deep enough in
the contact. Refer to Figure 5. This will decrease or
increase the wire insertion depth by approximately
0.20 [.008].
3. Install the head onto the power unit according to
the instructions packaged with the power unit.
Make sure to observe any cautions and dangers.
Figure 5
Turn CLOCKWISE
To Decrease
Wire Insertion Depth
Turn COUNTERCLOCKWISE
To Increase
Wire Insertion Depth
Adjuster
Wire Insertion Depth Adjustment