background image

408- 9085

Terminating Head 58062- 1

3

of 5

Rev

B

Tyco Electronics Corporation

Figure 4

Top of Wire Conductor Below

Top of Wire Barrel Slot

Top of Wire

Barrel Slot

Correct

Acceptable

Termination Inspection

Incorrect

Wire Was Not Inserted

Deep Enough During

Termination

Wire Was Not Inserted

Straight Before

Termination

Wire Was Not Fully

Inserted Before

Termination

Wire Was Inserted With

Too Much Force During

Termination

Damaged Housing—

Connector Was Too

Tight or Too Loose in

Head During Termination

A

A

0.51

[.020]

Min

Section A--A

Arms of Insulation Support

Barrel Partially Closed

Arms of Insulation Support

Barrel Completely Closed

AMPMODU MT

Receptacle Connector

B. Manual and Electric Power Units

1. Remove the head from the power unit according

to the instructions packaged with the power unit.

Make sure to observe any cautions and dangers.

2. Turn the adjuster one--sixth of a revolution

clockwise

if the wire is too deep in the contact, and

counterclockwise

if the wire is not deep enough in

the contact. Refer to Figure 5. This will decrease or

increase the wire insertion depth by approximately

0.20 [.008].

3. Install the head onto the power unit according to

the instructions packaged with the power unit.

Make sure to observe any cautions and dangers.

Figure 5

Turn CLOCKWISE

To Decrease

Wire Insertion Depth

Turn COUNTERCLOCKWISE

To Increase

Wire Insertion Depth

Adjuster

Wire Insertion Depth Adjustment

Отзывы: