408- 10048
Hand Crimping Tool 1804834- 1 and Crimping Head 1- 1804834- 1
3
of 5
Rev
B
Tyco Electronics Corporation
Wire Range
Stamped Here
Crimps centered. Crimps may be off center BUT NOT
OFF END OF WIRE BARREL.
Wire size matches wire color range on splice and
tool.
Wire insulation does not enter wire barrel.
Wire is visible through inspection hole of butt splices.
Wire is flush with or extends slightly beyond end of wire
barrel.
On parallel splices, bare wire ends must be flush
with or extended slightly beyond end of wire barrel.
Crimped off end of splice or terminal wire barrel.
Wire size does not match wire size or color range on
splice or tool.
Wire insulation entered wire barrel of terminal or
splice. CHECK FOR INCORRECT STRIP LENGTH.
Wire not inserted far enough in terminal or splice. End
of wire must be visible through inspection hole of butt
splices, and be flush with or extend slightly beyond end
of wire barrel.
Excessive “flash” on terminal or splice indicates damaged
jaws or wrong wire, splice, or tooling combination was
used.
Nicked or missing strands.
MiniSeal Splice
Figure 4
3
1
3
4
2
1
2
3
4
5
1
2
3
4
5
6
4
1
3
5
2
ACCEPT
REJECT
2. Close tool handles until ratchet releases and
then allow them to open freely. If they do not open
quickly and fully, the spring is defective and must
be replaced. See Section 6, REPLACEMENT AND
REPAIR.
Figure 5
Pitted
Chipped
Edge
Flattened Area
Broken Corner
3. Inspect head assembly for worn, cracked, or
broken jaws. Refer to Figure 5. If damage is
evident, return the tool to Tyco Electronics for
evaluation and repair. See Section 6,
REPLACEMENT AND REPAIR.
5.4. Gaging the Crimping Chambers
This inspection requires the use of a plug gage
conforming to the dimensions provided in Figure 6.
Tyco Electronics does not manufacture or market
these gages. To gage the crimping chambers,
proceed as follows:
1. Remove traces of oil or dirt from the crimping
chambers and plug gage.
2. Close the tool handles until it is evident that the
jaws have bottomed; then hold in this position. Do
NOT force the jaws beyond initial contact.
3. Align the GO element with the crimping
chamber. Push element straight into the crimping
chamber without using force. The GO element
must pass completely through the crimping
chamber.