408- 10048

Hand Crimping Tool 1804834- 1 and Crimping Head 1- 1804834- 1

3

of 5

Rev

B

Tyco Electronics Corporation

Wire Range

Stamped Here

Crimps centered. Crimps may be off center BUT NOT

OFF END OF WIRE BARREL.
Wire size matches wire color range on splice and

tool.
Wire insulation does not enter wire barrel.

Wire is visible through inspection hole of butt splices.

Wire is flush with or extends slightly beyond end of wire

barrel.

On parallel splices, bare wire ends must be flush

with or extended slightly beyond end of wire barrel.

Crimped off end of splice or terminal wire barrel.

Wire size does not match wire size or color range on

splice or tool.
Wire insulation entered wire barrel of terminal or

splice. CHECK FOR INCORRECT STRIP LENGTH.
Wire not inserted far enough in terminal or splice. End

of wire must be visible through inspection hole of butt

splices, and be flush with or extend slightly beyond end

of wire barrel.

Excessive “flash” on terminal or splice indicates damaged

jaws or wrong wire, splice, or tooling combination was

used.

Nicked or missing strands.

MiniSeal Splice

Figure 4

3

1

3

4

2

1

2

3

4

5

1

2

3

4

5

6

4

1

3

5

2

ACCEPT

REJECT

2. Close tool handles until ratchet releases and

then allow them to open freely. If they do not open

quickly and fully, the spring is defective and must

be replaced. See Section 6, REPLACEMENT AND

REPAIR.

Figure 5

Pitted

Chipped

Edge

Flattened Area

Broken Corner

3. Inspect head assembly for worn, cracked, or

broken jaws. Refer to Figure 5. If damage is

evident, return the tool to Tyco Electronics for

evaluation and repair. See Section 6,

REPLACEMENT AND REPAIR.

5.4. Gaging the Crimping Chambers

This inspection requires the use of a plug gage

conforming to the dimensions provided in Figure 6.

Tyco Electronics does not manufacture or market

these gages. To gage the crimping chambers,

proceed as follows:

1. Remove traces of oil or dirt from the crimping

chambers and plug gage.

2. Close the tool handles until it is evident that the

jaws have bottomed; then hold in this position. Do

NOT force the jaws beyond initial contact.

3. Align the GO element with the crimping

chamber. Push element straight into the crimping

chamber without using force. The GO element

must pass completely through the crimping

chamber.