Turn - Quick Start Guide
Fan controller
The fan controller requires an analogue join
to indicate the fan speed index. There can be
a maximum of 8 speeds and off. There is a
corresponding incoming join which takes the
fan speed number as its value. Out of range
values are ignored.
Reset command
The reset join is an incoming digital join and responds to the ON value. OFF is ignored.
Turn ready command
The TURN_READY command is sent once Turn has booted up and initialises the connection to the Cresnet bus. It is an
outgoing digital join and sends an ON signal. OFF is not used. Once this has been received by the Crestron program, the
current values of all signals should be sent to Turn, and the TURN_READY join should be set low ready to receive it again.