background image

 

http://www.tyan.com 

17 

DBG_HD1: TYAN Module Header  

 

Signal 

Pin 

Pin 

Signal 

VCC3 

FRAME_N 

LAD0 

KEY 

LAD1 

PLT_RST_N 

LAD2 

GND 

LAD3 

10 

CLK_33M 

DBG_SERIRQ 

11 

12 

GND 

DBG_PRES_N 

13 

14 

VCC3_AUX 

TPM_ADDR_MB 

15 

16 

PCH_TPM_PP_EN 

FAN_HD1: Fan Connector (Reserved for Barebone) 

 

Signal 

Pin 

Pin 

Signal 

TACH1 

TACH6 

TACH2 

TACH7 

TACH3 

TACH8 

TACH4 

TACH9 

TACH5 

10 

TACH10 

GND 

11 

12 

KEY 

PWM2 

13 

14 

PWM1 

TACH11 

15 

16 

SDA 

TACH12 

17 

18 

SCL 

NC 

19 

20 

PWM3 

USB3_FPIO1: Front USB3.0 Header 

 

Signal 

Pin 

Pin 

Signal 

+5V 

20 

KEY 

P0_RX_N 

19 

+5V 

P0_RX_P 

18 

P1_RX_N 

GND 

17 

P1_RX_P 

P0_TX_N 

16 

GND 

P0_TX_P 

15 

P1_TX_N 

GND 

14 

P1_TX_P 

P0_N 

13 

GND 

P0_P 

12 

P1_N 

OC_N 

10 

11 

P1_P 

 

Содержание S7126

Страница 1: ...ndows are trademarks of Microsoft Corporation Nuvoton is a trademark of Nuvoton Technology Corporation Notice Information contained in this document is furnished by MITAC COMPUTING TECHNOLOGY CORPORAT...

Страница 2: ...http www tyan com 2...

Страница 3: ...therboard in Chassis 33 2 8 Installing the Memory 35 2 9 Attaching Drive Cables 44 2 10 Installing Add In Cards 45 2 11 Connecting External Devices 46 2 12 Installing the Power Supply 47 2 13 Finishin...

Страница 4: ...n the following 1 x S7126 Motherboard 2 x SATA Signal Cable 1 x M 2 Latch Kit 1 x Rear I O Shield 2 x CPU Carrier 1 x S7126 Quick reference guide IMPORTANT NOTE Sales sample may not come with the acce...

Страница 5: ...y to meet demanding requirements for today s IT environments Remember to visit the TYAN website at http www tyan com There you can find all the information on all TYAN products as well as all the supp...

Страница 6: ...pin power connectors Others 1 ID button TPM Optional TPM Support Please refer to our TPM supported list System Monitoring Chipset Aspeed AST2500 Fan Total 6 4 pin headers Temperature Monitors tempera...

Страница 7: ...F 95 F Non operating Temp 40 C 70 C 40 F 158 F In Non operating Humidity 90 non condensing at 35 C RoHS RoHS 6 6 Compliant Yes Operating System OS supported list Please refer to our AVL support lists...

Страница 8: ...http www tyan com 8 NOTE...

Страница 9: ...conditions MITAC recommends wearing a static safety wrist strap 2 Hold the motherboard by its edges and do not touch the bottom of the board or flex the board in any way 3 Avoid touching the motherboa...

Страница 10: ...tp www tyan com 10 2 1 Board Image S7126 This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above pictu...

Страница 11: ...http www tyan com 11 2 2 Block Diagram S7126 Block Diagram...

Страница 12: ...http www tyan com 12 2 3 Mainboard Mechanical Drawing...

Страница 13: ...of the latest board revision available at the time of publishing The board you receive may not look exactly like the above diagram But for the DIMM number please refer to the above placement for memor...

Страница 14: ...5 SSATA_SGPIO1 29 CPU0_FAN CPU0_FAN 12 COM2 header HD_COM2 30 SSI 8 pin CPU0 Power connector PW1 13 Power BTN PWR_BTN 31 FRONT FAN_2 SYS_FAN_2 14 FAN pin header FAN_HD1 32 FRONT FAN_1 SYS_FAN_1 15 Int...

Страница 15: ...ctive LED HDD_LED1 XXII Memory Error LED CPU0 LED66 VIII CPU ERROR LED ERR_LED1 XXIII Memory Error LED CPU0 LED65 IX CPU ERROR LED CAT_LED1 XXIV Memory Error LED CPU0 LED61 X CPU ERROR LED ERR_LED0 XX...

Страница 16: ...PWER VCC3_Aux KEY 3 4 FP_ID_LED_PW FP_PW_LED_GND 5 6 FP_ID_LED_N HDD_LED_PW 7 8 BMC_HW_FAULT_N HDD_ACT_LED_N 9 10 BMC_SYS_FAULT_N FP_PWR_BTN_N 11 12 LAN0_LED_P GND 13 14 LAN0_LED_N FP_RST_BTN_JP_N 15...

Страница 17: ...Fan Connector Reserved for Barebone Signal Pin Pin Signal TACH1 1 2 TACH6 TACH2 3 4 TACH7 TACH3 5 6 TACH8 TACH4 7 8 TACH9 TACH5 9 10 TACH10 GND 11 12 KEY PWM2 13 14 PWM1 TACH11 15 16 SDA TACH12 17 18...

Страница 18: ...7 8 HD_VGA_B GND 9 10 HD_VGA_DAT HD_VGA_HS 11 12 KEY HD_VGA_CLK 13 14 HD_VGA_VS HD_COM2 COM Port Header Signal Pin Pin Signal COM2_DCD 1 2 COM2_DSR COM2_RXD 3 4 COM2_RTS COM2_TXD 5 6 COM2_CTS COM2_DT...

Страница 19: ...nal GND 1 2 3 4 FP_RST_BTN_N sSATA4 7 pin Vertical SATA Connector PIN Define Pin Connects to the Serial ATA ready drives via the Serial ATA cable 1 GND 2 SSATA4_TXP_C 3 SSATA4_TXN_C 4 GND 5 SSATA4_RXN...

Страница 20: ...ave forgotten your system setup password or need to clear system BIOS setting 1 Power off the system and disconnect power connectors from the motherboard 2 Press the button Clear CMOS 3 Reconnect powe...

Страница 21: ...RX_N 29 30 P12V_IN PCH_PE1_M2_1_RX_P 31 32 P12V_IN GND 33 34 P12V_IN PCH_PE1_M2_1_TX_N 35 36 P12V_IN PCH_PE1_M2_1_TX_P 37 38 NC GND 39 40 M2_SMB_CLK_R PCH_PE0_M2_0_RX_N 41 42 M2_SMB_DAT_R PCH_PE0_M2_0...

Страница 22: ...GND SSATA1_RXP_C A4 B4 SSATA0_RXP_C SSATA1_RXN_C A5 B5 SSATA0_RXN_C GND A6 B6 GND SSATA3_RXP_C A7 B7 SSATA2_RXP_C SSATA3_RXN_C A8 B8 SSATA2_RXN_C GND A9 B9 GND SSGPIO_DO_0R C1 D1 SSGPIO_DI_0R GND C2...

Страница 23: ...4 D4 SATA0_TXP_C SATA1_TXN_C C5 D5 SATA0_TXN_C GND C6 D6 GND SATA3_TXP_C C7 D7 SATA2_TXP_C SATA3_TXN_C C8 D8 SATA2_TXN_C GND C9 D9 GND NC_PCH_SATA_0 7_A10 A10 B10 GND SGPIO_SATA_CLK A11 B11 SGPIO_SATA...

Страница 24: ..._ABCD_RX_DN3 A17 B17 CPU1_PE2_ABCD_TX_DP3_C CPU1_PE2_ABCD_RX_DP3 A18 B18 CPU1_PE2_ABCD_TX_DN3_C GND A19 B19 GND SlimSAS2 Vertical Slim SAS Connector Signal Name Pin Pin Signal Name GND A1 B1 GND CPU1_...

Страница 25: ...DN11 A17 B17 CPU1_PE2_ABCD_TX_DP11_C CPU1_PE2_ABCD_RX_DP11 A18 B18 CPU1_PE2_ABCD_TX_DN11_C GND A19 B19 GND SlimSAS4 Vertical Slim SAS Connector Signal Name Pin Pin Signal Name GND A1 B1 GND CPU1_PE2_A...

Страница 26: ...M PORT2 Default Pin2 3 closed BMC CONSOLE PORT5 J119 BMC COM Port Jumper Signal Pin Pin Signal BMC_COM2_TXD 1 2 TXD_2 BMC_COM5_TXD 3 Pin1 2 closed BMC COM PORT2 Default Pin2 3 closed BMC CONSOLE PORT5...

Страница 27: ...n Pin Signal 1KK to VCC3_AUX 1 2 10K to GND Pin1 2 closed PP PECI to BMC Default Pin1 2 open NI PECI to PCH J120 System Buzzer Jumper VCC5_BZ 1 2 NA BUZ_1 3 4 BUZ_2 Pin3 4 closed Normal Mode Default P...

Страница 28: ...FF OFF The LED shuts off when the BMC controller cannot be detected or properly initiated Blinking Green The LED blinks per second to indicate that the BMC controller is working normally P0_PG_LED1 CP...

Страница 29: ...l VCC3_AUX GND State Description OFF OFF The LED shuts off when the PSU is normal ON Green The LED lights up when the PSU is abnormally ID_LED1 Rear ID LED Pin Signal VCC3_AUX GND State Description OF...

Страница 30: ...uration Processor Installation for Intel LGA4189 Socket Follow the steps below to install the processors and heat sinks NOTE Please save and replace the CPU protection cap when returning for service 1...

Страница 31: ...g an alcohol solvent Then apply new thermal grease before reinstalling the heatsink 3 Remove the CPU cover 4 Carefully flip the heatsink assembly Align the heatsink with the CPU socket by the guide pi...

Страница 32: ...30 Security Torx to tighten the screws in a sequential order 1 2 3 4 NOTE When disassembling the heatsink loosen the screws in reverse order 4 3 2 1 NOTE Always check with the manufacturer of the heat...

Страница 33: ...ply lay the motherboard inside the chassis and align the screw holes of the motherboard to the studs inside the case If there are any studs missing you will know right away since the motherboard will...

Страница 34: ...http www tyan com 34...

Страница 35: ...eight channel memory interfaces supporting DDR4 and Intel OptaneTM PMem memory technology Each channel consists of 64 data and 8 ECC bits Each channel supports up to two DIMMs Support is provided for...

Страница 36: ...d across different sockets Mixing of RDIMMs and LRDIMMs is not allowed in the same channel across different channels and across different sockets Mixing of PMem module with RDIMMs is supported in Whit...

Страница 37: ...at least one DDR4 DIMM per socket If only one DIMM is populated in a channel then populate it in the slot furthest away from CPU of that channel Always populate the DIMM with the higher electrical loa...

Страница 38: ...at least one DDR4 If only one DIMM is populated in a channel then populate it in the slot furthest away from CPU of that channel Always populate the DIMM with the higher electrical loading on a chann...

Страница 39: ...ng only applies to 1LM mode SNC and Hemi UBS apply only to 1LM MM volatile region Note 2 Intel OptaneTM PMem 200 series ADx1 non interleave supports fall back to each 8 x configs with Intel OptaneTM P...

Страница 40: ...http www tyan com 40 DIMM Location...

Страница 41: ..._DIM_CH_E0 or P0_MC1_DIM_CH_C0 P0_MC3_DIM_CH_G0 4 DIMMs P0_MC0_DIM_CH_A0 P0_MC1_DIM_CH_C0 P0_MC2_DIM_CH_E0 P0_MC3_DIM_CH_G0 or P0_MC0_DIM_CH_B0 P0_MC1_DIM_CH_D0 P0_MC2_DIM_CH_F0 P0_MC3_DIM_CH_H0 6 DIM...

Страница 42: ...nstalled 2 4 6 8 10 12 14 16 P0_MC0_DIM_CH_A0 P0_MC0_DIM_CH_B0 P0_MC1_DIM_CH_C0 P0_MC1_DIM_CH_D0 P0_MC2_DIM_CH_E0 P0_MC2_DIM_CH_F0 P0_MC3_DIM_CH_G0 P0_MC3_DIM_CH_H0 P1_MC0_DIM_CH_A0 P1_MC0_DIM_CH_B0 P...

Страница 43: ...structions to install memory modules into the S7126 1 Unlock the clips as shown in the illustration 2 Insert the memory module firmly into the socket by gently pressing down until it sits flush with t...

Страница 44: ...are very simple There is no need to set Master Slave jumpers on SATA drives If you are in need of SATA SAS cables or power adapters please contact your place of purchase The following pictures illust...

Страница 45: ...the card firmly Do not force any add in cards into any slots if they do not seat in place It is better to try another slot or return the faulty card rather than damaging both the motherboard and the a...

Страница 46: ...equired to complete the installation Onboard LAN LED Color Definition The five 5 onboard Ethernet ports have green and yellow LEDs to indicate LAN status The chart below illustrates the different LED...

Страница 47: ..._PS_ON_N GND 5 17 GND VCC5 6 18 GND GND 7 19 GND ATX_PG 8 20 NC_PWR1_20 VCC5_SB 9 21 VCC5 P12V_IN 10 22 VCC5 P12V_IN 11 23 VCC5 VCC3 12 24 GND PW1 8 PIN Power Connector Signal Pin Pin Signal GND 1 5 V...

Страница 48: ...roperly especially IDE cables and most importantly jumpers You may have difficulty powering on your system if the motherboard jumpers are not set correctly In the rare circumstance that you have exper...

Страница 49: ...and configurations of the BIOS are current at the time of print and are subject to change and therefore may not match exactly what is displayed on screen This section describes the BIOS setup program...

Страница 50: ...r best performance and reliability Even a seemingly small change to the Chipset setup options may cause the system to become unstable or unusable 3 1 4 Setup Variations Not all systems have the same B...

Страница 51: ...options that can directly be changed within the Main Setup screen System Language Choose the system default language English Simplified Chinese Japanese System Date Set the Date Use Tab to switch bet...

Страница 52: ...he HII network drivers displayed here depend on the card s you installed and the functions you enabled Option ROM Dispatch Policy Option ROM Dispatch Policy S5 RTC Wake Settings Enable system to wake...

Страница 53: ...s SATA Configuration SATA devices and settings PCH Configuration SATA Device Information Miscellaneous Configuration Miscellaneous Configuration Runtime Error Logging Press Enter to view or change the...

Страница 54: ...onfiguration MAC XXXXXXXXXXXX VLAN Configuration MAC XXXXXXXXXXXX MAC XXXXXXXXXXXX IPV4 Network Configuration Configure network parameters MAC XXXXXXXXXXXX MAC XXXXXXXXXXXX IPV6 Network Configuration...

Страница 55: ...k parameters MAC XXXXXXXXXXXX MAC XXXXXXXXXXXX IPV6 Network Configuration Configure IPV6 network parameters MAC XXXXXXXXXXXX Intel Virtual RAID on CPU This formset allows the user to manage Intel Virt...

Страница 56: ...as UEFI X Legacy Embedded ROM s VIDx8086 DIDx1533 s0 Bx2 Dx0 Fx0 Enabled Disabled On Board LAN2 I210 Onboard Device has UEFI X Legacy Embedded ROM s VIDx8086 DIDx1533 s0 Bx3 Dx0 Fx0 Enabled Disabled S...

Страница 57: ...wake on the day hr min sec specified Disabled Fixed Time Dynamic Time When Wake system from S5 is set to Fixed Time Wake up hour Select 0 23 For example enter 3 for 3am and 15 for 3pm Wake up minute...

Страница 58: ...m 58 3 3 3 Trusted Computing Security Device Support Enables or Disables BIOS support for security device O S will not show Security Device TCG EFI protocol and INT1A interface will not be available E...

Страница 59: ...ACPI Auto Configuration Enable or Disable BIOS ACPI Auto Configuration Disabled Enabled Enable Hibernation Enable or Disable System ability to Hibernate OS S4 Sleep State This option may not be effect...

Страница 60: ...ww tyan com 60 3 3 5 AST2500 Super IO Configuration Super IO Chip Read only Serial Port 1 Configuration Set Parameters of Serial Port 1 COMA Serial Port 2 Configuration Set Parameters of Serial Port 2...

Страница 61: ...rt Enable or disable Serial Port COM Enabled Disabled Change Settings Select an optimal setting for Super IO Device Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12...

Страница 62: ...rt Enable or disable Serial Port COM Enabled Disabled Change Settings Select an optimal setting for Super IO Device Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12...

Страница 63: ...http www tyan com 63 3 3 6 Power Management CPU Power and Performance Policy CPU Power and Performance Policy Performance Balanced Power Power...

Страница 64: ...Console redirection enable or disable Disabled Enabled Legacy Console Redirection Settings Legacy Console redirection settings Console Redirection Settings The settings specify how the host computer...

Страница 65: ...rial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 57600 115200 Data Bits 8 7 Parity A parity bit can be sent with t...

Страница 66: ...t to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS VT UTF8 Combo Key...

Страница 67: ...rial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 57600 115200 Data Bits 8 7 Parity A parity bit can be sent with t...

Страница 68: ...t to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS VT UTF8 Combo Key...

Страница 69: ...OM2 Resolution On Legacy OS the Number of Rows and Columns supported redirection 80x24 80x25 Redirect After POST When BootLoader is selected then Legacy Console Redirection is disabled before booting...

Страница 70: ...rver OS through a serial port COM1 COM2 Terminal Type VT UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection Se...

Страница 71: ...data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses two wires t...

Страница 72: ...r Disables 64bit capable Devices to be Decoded in Above 4G Address Space Only if System Supports 64 bit PCI Decoding Enabled Disabled SR IOV Support If system has SR IOV capable PCIe Devices this opti...

Страница 73: ...option to change the Common RefCode Settings UPI Configuration Displays and provides option to change the Uncore Settings Memory Configuration Displays and provides option to change the Memory Setting...

Страница 74: ...TXT Enable Intel TXT Disabled Enabled Intel Virtualization Technology Intel Virtualization Technology allows a platform to run multiple operating systems and applications in independent partitions Not...

Страница 75: ...http www tyan com 75 3 3 9 1 1 Per Socket Configuration CPU Socket 0 Configuration CPU Socket 0 Configuration CPU Socket 1 Configuration CPU Socket 1 Configuration...

Страница 76: ...com 76 3 3 9 1 1 1 CPU Socket 0 Configuration Core Disable Bitmap Hex 0 Enable all cores FFFFFFFFFF Disable all cores NOTE At least one core per CPU must be enabled Disabling all cores is an invalid c...

Страница 77: ...com 77 3 3 9 1 1 2 CPU Socket 1 Configuration Core Disable Bitmap Hex 0 Enable all cores FFFFFFFFFF Disable all cores NOTE At least one core per CPU must be enabled Disabling all cores is an invalid c...

Страница 78: ...512M 1G 2G Auto MMIO High Base Select MMIO High Base 56T 40T 32T 24T 16T 4T 3T 2T 1T MMIO High Granularity Size Selects the allocation size used to assign mmioh resources Total mmioh space can be up t...

Страница 79: ...http www tyan com 79 Numa Enable or Disable Non uniform Memory Access NUMA Disabled Enabled...

Страница 80: ...http www tyan com 80 3 3 9 3 UPI Configuration UPI General Configuration Displays and provides option to change the UPI General Settings...

Страница 81: ...Link Frequency Select Allows for selecting the UPI Link Frequency 9 6GT s 10 4GT s 11 2GT s Auto Use Per Link Setting Link L0p Enable Enable Set the c_l0p_en Disable Reset it Auto Auto decides based o...

Страница 82: ...I Prefetch enable 4 IMC may interleave SNC2 Enable supports 2 clusters SNC and 2 way IMC interleave SNC4 Enable supports 4 clusters SNC and 1 way IMC interleave Enable SNC2 or SNC4 will gray out IMC i...

Страница 83: ...http www tyan com 83 3 3 9 3 1 1 UPI Status Read only...

Страница 84: ...support Auto Sets it to the MRC default setting current default is Enable Enforce POR Disabled Memory Frequency Maximum Memory Frequency Selections in Mhz If Enforce POR is disabled user will be able...

Страница 85: ...http www tyan com 85 Interleave NVDIMMs Controls if NVDIMMs are interleaved together or not Enabled Disabled...

Страница 86: ...of memory to be mirrored If rank sparing is enabled partial mirroring will not take effect Enabling any type of Mirror Mode will disable XPT Prefetch Disabled Full Mirror Mode Partial Mirror Mode Mir...

Страница 87: ...VMD for Volume Management Device Configuration menu PCIe Hot Plug Enable Disable PCIe Hot Plug globally Disabled Enabled PCIe ACPI Hot Plug Enable Disable PCIe ACPI Hot Plug globally or allow per port...

Страница 88: ...http www tyan com 88 Skip PCIe retimers detection Skip PCIe retimers detection to speedup the boot Retimers are present only in specific HW configurations Disabled Enable...

Страница 89: ...slot s x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 NOTE The default setting is x16 for MB x8x8 for TS65 B7126 IOU3 IIO PCIe Port 4 Selects PCIe port Bifurcation for selected slot s x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16...

Страница 90: ...ble is used to disable the port and hide its CFG space Auto Disabled Enabled Hot Plug Capable This option specifies if the link is considered Hot Plug capable Auto Disabled Enabled Surprise Hot Plug C...

Страница 91: ...ntrol LNKCON2 6 for this PCIe port 6 0 dB 3 5 dB PCI E Port MPSS Configure Max Payload Size supported in PCIe Device Capabilities register 128B 256B 512B Auto PCI E ASPM Support This option enables di...

Страница 92: ...NOTE The default setting is x16 for MB x8x8 for TS65 B7126 IOU3 IIO PCIe Port 4 Selects PCIe port Bifurcation for selected slot s x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 NOTE The default setting is x4x4x4x4 f...

Страница 93: ...e Disable is used to disable the port and hide its CFG space Auto Disabled Enabled Hot Plug Capable This option specifies if the link is considered Hot Plug capable Auto Disabled Enabled Surprise Hot...

Страница 94: ...ntrol LNKCON2 6 for this PCIe port 6 0 dB 3 5 dB PCI E Port MPSS Configure Max Payload Size supported in PCIe Device Capabilities register 128B 256B 512B Auto PCI E ASPM Support This option enables di...

Страница 95: ...9 5 3 Intel VT for Directed I O VT d Intel VT for Directed I O VT d Enable Disable Intel Virtualization Technology for Directed I O VT d by reporting the I O device assignment to VMM through DMAR ACPI...

Страница 96: ...http www tyan com 96 3 3 9 5 4 Intel VMD Technology...

Страница 97: ...e VMD in this Stack Disabled Enabled VMD Config for IOU0 Enable Disable VMD in this Stack Disabled Enabled VMD Config for IOU1 Enable Disable VMD in this Stack Disabled Enabled VMD Config for IOU2 Ena...

Страница 98: ...http www tyan com 98 VMD Config for IOU4 Enable Disable VMD in this Stack Disabled Enabled...

Страница 99: ...Enable Disable VMD Enable Disable VMD in this Stack Disabled Enabled VMD Config for IOU1 Enable Disable VMD Enable Disable VMD in this Stack Disabled Enabled VMD Config for IOU2 Enable Disable VMD Re...

Страница 100: ...f Enable Disabled VMD VMD Port A VMD Port B VMD Port C VMD Port D is set to Disabled for MB and Enabled for Barebone Hot Plug Capable Enable Disable Hot Plug for PCIe Root Ports Disabled Enabled CfgBa...

Страница 101: ...20 MemBar2 attribute Set up VMD Memory BAR2 attribute like 64 bit or prefetchable 32 bit non prefetchable 64 bit non prefetchable 64 bit prefetchable VMD for Direct Assign Enable Disable VMD for Direc...

Страница 102: ...anagement Configuration CPU P State Control P State Control Configuration Sub Menu include Turbo XE and ete Hardware PM State Control Hardware P State setting CPU C State Control CPU C State setting P...

Страница 103: ...namic SSTPP Select Disabled Enabled Intel SST PP Intel SST PP Select allows user to choose from up to two additional base frequency conditions Base Config 3 Config 4 Energy Efficient Turbo Energy Effi...

Страница 104: ...http www tyan com 104 Perf P Limit Enable Disable Performance P Limit Disabled Enabled...

Страница 105: ...Disable Hardware chooses a P state based on OS Request Legacy P States Native Mode Hardware chooses a P state based on OS guidance Out of Band Mode Hardware autonomously chooses a P state no OS guidan...

Страница 106: ...e C State Package C State limit C0 C1 state C2 state C6 non Retention state Auto CPU C6 report Enable Disable CPU C6 ACPI C3 report to OS Disabled Enabled Auto Enhanced Halt State C1E Core C1E auto pr...

Страница 107: ...abled PL1 Power Limit PL1 Power Limit in Watts The value may vary from 0 to Fused value If the value is 0 the fused value will be programmed A value greater than fused TDP value will not be programmed...

Страница 108: ...ime Window Disabled Enabled PL2 Power Limit PL2 Power Limit in Watts The value may vary from 0 to Fused value If the value is 0 BIOS programs 125 TDP 0 PL2 Time Window PL2 value in seconds The value m...

Страница 109: ...http www tyan com 109 3 3 10 Memory Topology Read only...

Страница 110: ...1 Server ME Configuration Altitude The altitude of the platform location above the sea level expressed in meters The hex number is decoded as 2 s complement signed integer Provide the 8000h value if t...

Страница 111: ...http www tyan com 111 3 3 12 SATA Configuration SATA Configuration SATA devices and settings SSATA Configuration sSATA devices and settings...

Страница 112: ...ed Configure SATA as Identify the SATA port is connected to Solid State Drive or Hard Disk Drive AHCI RAID Support Aggressive Link Power Management Enables Disables SALP Disabled Enabled Port 0 1 2 3...

Страница 113: ...ormed and only the drives witch have this option enabled will spin up at boot Otherwise all drives spin up at boot Disabled Enabled SATA Device Type Identify the SATA port is connected to Solid State...

Страница 114: ...bled Configure sSATA as Identify the sSATA port is connected to Solid State Drive or Hard Disk Drive AHCI RAID Support Aggressive Link Power Management Enables Disables SALP Disabled Enabled Port 0 1...

Страница 115: ...drives witch have this option enabled will spin up at boot Otherwise all drives spin up at boot Disabled Enabled sSATA Device Type Identify the SATA port is connected to Solid State Drive or Hard dis...

Страница 116: ...nfiguration PCH Devices Enable Disable Intel IO Controller Hub devices PCI Express Configuration PCI Express Configuration settings USB Configuration USB Configuration Settings ADR Configuration Autom...

Страница 117: ...http www tyan com 117 3 3 13 1 PCH Devices Restore AC Power Loss Select S0 S5 for ACPI state after a G3 Power On Power Off Last State...

Страница 118: ...http www tyan com 118 3 3 13 2 PCI Express Configuration PCI Express Root Port 1 20 PCI Express Root Port 1 20 Settings...

Страница 119: ...ess Root Port Disabled Enabled ASPM Support Set the ASPM Level Force L0s Force all links to L0s state AUTO BIOS auto configure DISABLE Disables ASPM Disable ASPM ASPM L1 ASPM Auto L1 Substates PCI Exp...

Страница 120: ...http www tyan com 120 Max Payload Size PCIE Max Payload Size Selection MPL128B MPL256B...

Страница 121: ...121 3 3 13 3 USB Configuration XHCI Idle L1 Enabled XHCI Idle L1 Disabled to workaround USB3 hot plug will fail after 1 hot plug removal Please put the system to G3 for the new settings to take effect...

Страница 122: ...Platform POR Enabled Disabled ADR GPIO Select between GPIO_B or GPIO_C GPIO_B GPIO_C Host Partition Reset ADR Enable Enables Disables ADR on Host Partition Reset Platform POR Enabled Disabled Enable...

Страница 123: ...http www tyan com 123 ADR timer multiplier Select proper ADR timer multiplier x1 8 24 40 56 64 72 80 88 96 Platform POR x1 x8 x24 x40 x56 x64 x72 x80 x88 x96...

Страница 124: ...http www tyan com 124 3 3 14 Miscellaneous Configuration Active Video Select active video type Onboard Device Offboard Device...

Страница 125: ...www tyan com 125 3 3 15 Runtime Error Logging System Errors System Error Enable Disable setup options Disabled Enabled Memory Error Enabling Press Enter to view or change the Memory errors enabling op...

Страница 126: ...http www tyan com 126 3 3 15 1 Memory Error Enabling Memory Error Enable Disable Memory Error Disabled Enabled Spare Interrupt Spare Interrupt Selection Disabled SMI Error Pin CMCI...

Страница 127: ...abled Enabled Auto XHCI Hand off This is a workaround for OSes without XHCI hand off support The XHCI ownership change should be claimed by XHCI driver Disabled Enabled USB Mass Storage Driver Support...

Страница 128: ...er up delay in seconds is available when Device power up delay is set to Manual Device power up delay in seconds Delay range is 1 40 seconds in one second increments 5 AMI Virtual CDROM0 1 00 Mass sto...

Страница 129: ...www tyan com 129 3 3 17 NVMe Configuration This page shows the Device Name you installed Press Enter to read the device information If no NVME device is installed it shows no NVME device is found Read...

Страница 130: ...LAN Enable Disable control function Enabled Disabled Onboard LAN 2 I210 LAN Enable Disable control function Enabled Disabled ICC Clock Spread Spectrum Turn on off Spread Spectrum Setting for IsCLK Ena...

Страница 131: ...http www tyan com 131 NMI Button Enable or Disable NMI button Enabled Disabled...

Страница 132: ...rface Settings Redfish Enable Disable AMI Redfish Enabled Disabled Authentication mode Select authentication mode Basic Authentication Session Authentication IP Address Enter IP address IP Mask Addres...

Страница 133: ...items are available when Network Stack is set to Enabled Ipv4 PXE Support Enable Ipv4 PXE Boot Support If disabled IPV PXE boot option will not be created Disabled Enabled Ipv4 HTTP Support Enable Ipv...

Страница 134: ...nable Ipv6 HTTP Boot Support If disabled IPV6 HTTP boot option will not be created Disabled Enabled PXE boot wait time Wait time to press ESC key to abort the PXE boot 0 Media detect count Number of t...

Страница 135: ...Speed Control BIOS setting from Manual to Full Speed when installing the Nvidia GeForce Quardro GPU and any VGA card PWM Minimal Duty Cycle PWM Minimal Duty Cycle 60 NOTE This item is available when...

Страница 136: ...http www tyan com 136 3 3 21 1 Sensor Data Register Monitoring NOTE SDR can not be modified Read only...

Страница 137: ...ADR Enables the detecting and enabling of ADR This is not available if eADR is enabled since eADR requires ADR to be enabled Enabled Disabled Assert ADR on Reset Assert ADR on Reset Enabled Disabled A...

Страница 138: ...U Registration Sign up the current CPU This item support INTEL CPU sign the CPU will record current CPU Once BIOS checked different with registered CPU show WARNING message on POST screen Deregistrati...

Страница 139: ...3 24 Memory Registration Sign up the current Memory Sign the Memory will record current Memory Once BIOS checked different with registered Memory show WARNING message on POST screen Deregistration Sig...

Страница 140: ...http www tyan com 140 3 3 25 T1s Auth Configuration Server CA Configuration Press Enter to configure Server CA Client Cert Configuration Press Enter to configure Client Cert...

Страница 141: ...http www tyan com 141 3 3 25 1 Server CA Configuration Enroll Cert Press Enter to enroll cert Delete Cert Press Enter to delete cert...

Страница 142: ...nroll Cert Enroll Cert Using File Enroll Cert Using File Cert GUID Input digit character in 11111111 2222 3333 4444 1234567890ab format Commit Changes and Exit Commit Changes and Exit Discard Changes...

Страница 143: ...http www tyan com 143 3 3 25 1 2 Delete Cert FE9C6606 8B49 44A3 8B6B DEA3A0E032 GUID for CERT Disabled Enabled...

Страница 144: ...low the instructions to initiate the iSCSI function Step 1 Select Advanced CSM Configuration Network UEFI Step 2 Select Advanced Network Stack Configuration Network Stack Enabled Step 3 Save changes a...

Страница 145: ...nitiator Only IQN format is accepted Enter iqn xxx xxx ranges from 4 to 223 Add an Attempt Add an Attempt Delete Attempts Delete one or more attempts Change Attempt Order Change the order of Attempts...

Страница 146: ...http www tyan com 146 3 3 26 1 1 Add an Attempt NOTE Only LAN1 supports iSCSI function MAC xx xx xx xx xx xx Intel I210 Gigabit Network Connection PFA Bus 2 Dev 0 Func 0...

Страница 147: ...tempt 1 Attempt iSCSI Mode Disabled Enabled Enabled for MPIO Disabled Enabled Enabled for MPIO Internet Protocol Initiator IP address is system assigned in IP6 mode In Autoconfigure mode iSCSI driver...

Страница 148: ...in dotted decimal notation Initiator Subnet Mask Enter IP address in dotted decimal notation Gateway Enter IP address in dotted decimal notation Target Name The worldwide unique name of the target On...

Страница 149: ...PFA Bus 2 Dev 0 Func 0 iSCSI mode Disabled IP version IPv4 Disabled Enabled Attempt 2 MAC xx xx xx xx xx xx PFA Bus 2 Dev 0 Func 0 iSCSI mode Disabled IP version IPv4 Disabled Enabled Commit Changes a...

Страница 150: ...t Order Change the order of Attempts using keys Use arrow keys to select the attempt then press to move the attempt up down in the attempt order list Attempt 1 Attempt 2 Commit Changes and Exit Commit...

Страница 151: ...http www tyan com 151 3 3 27 VLAN Configuration MAC xxxxxxxxxxxx Enter Configuration Menu Press ENTER to enter configuration menu for VLAN configuration...

Страница 152: ...27 1 Enter Configuration Menu VLAN ID VLAN ID of new VLAN or existing VLAN valid value is 0 4094 Priority 802 1Q Priority valid value is 0 7 Add VLAN Create a new VLAN or update existing VLAN Remove V...

Страница 153: ...www tyan com 153 3 3 28 MAC xxxxxxxxxxxx IPv4 Network Configuration Configured Indicate whether network address configured successfully or not Disabled Enabled Save Changes and Exit Save Changes and...

Страница 154: ...http www tyan com 154 3 3 29 MAC xxxxxxxxxxxx IPv6 Network Configuration Enter Configuration Menu Press ENTER to enter configuration menu for IPv6 configuration...

Страница 155: ...DAD Transmit Count The number of consecutive Neighbor Solicitation messages sent while performing Duplicate Address Detection on a tentative address A value of zero indicates that Duplicate Address D...

Страница 156: ...4 New Gateway addresses Gateway IP address can only be configured under manual policy e g 2002 3 Separate the IP address with blank space to configure more than one address New DNS addresses DNS addre...

Страница 157: ...ttp www tyan com 157 3 3 30 Intel I210 Gigabit Network Connection xx xx xx xx xx xx NIC Configuration Click to configure the network device port Blink LEDs Blink LEDs for a duration up to 15 seconds 0...

Страница 158: ...ocol Auto Negotiated 10 Mbps Half 10Mbps Full 100Mbps Half 100Mbps Full Wake On LAN Enables power on of the system via LAN Note that configuring Wake on LAN in the operating system does not change the...

Страница 159: ...http www tyan com 159 3 3 31 VLAN Configuration MAC xxxxxxxxxxxx Enter Configuration Menu Press ENTER to enter configuration menu for VLAN configuration...

Страница 160: ...31 1 Enter Configuration Menu VLAN ID VLAN ID of new VLAN or existing VLAN valid value is 0 4094 Priority 802 1Q Priority valid value is 0 7 Add VLAN Create a new VLAN or update existing VLAN Remove V...

Страница 161: ...www tyan com 161 3 3 32 MAC xxxxxxxxxxxx IPv4 Network Configuration Configured Indicate whether network address configured successfully or not Disabled Enabled Save Changes and Exit Save Changes and...

Страница 162: ...http www tyan com 162 3 3 33 MAC xxxxxxxxxxxx IPv6 Network Configuration Enter Configuration Menu Press ENTER to enter configuration menu for IPv6 configuration...

Страница 163: ...DAD Transmit Count The number of consecutive Neighbor Solicitation messages sent while performing Duplicate Address Detection on a tentative address A value of zero indicates that Duplicate Address D...

Страница 164: ...4 New Gateway addresses Gateway IP address can only be configured under manual policy e g 2002 3 Separate the IP address with blank space to configure more than one address New DNS addresses DNS addre...

Страница 165: ...ttp www tyan com 165 3 3 34 Intel I210 Gigabit Network Connection xx xx xx xx xx xx NIC Configuration Click to configure the network device port Blink LEDs Blink LEDs for a duration up to 15 seconds 0...

Страница 166: ...ocol Auto Negotiated 10 Mbps Half 10Mbps Full 100Mbps Half 100Mbps Full Wake On LAN Enables power on of the system via LAN Note that configuring Wake on LAN in the operating system does not change the...

Страница 167: ...http www tyan com 167 3 3 35 VLAN Configuration MAC xxxxxxxxxxxx Enter Configuration Menu Press ENTER to enter configuration menu for VLAN configuration...

Страница 168: ...35 1 Enter Configuration Menu VLAN ID VLAN ID of new VLAN or existing VLAN valid value is 0 4094 Priority 802 1Q Priority valid value is 0 7 Add VLAN Create a new VLAN or update existing VLAN Remove V...

Страница 169: ...www tyan com 169 3 3 36 MAC xxxxxxxxxxxx IPv4 Network Configuration Configured Indicate whether network address configured successfully or not Disabled Enabled Save Changes and Exit Save Changes and...

Страница 170: ...http www tyan com 170 3 3 37 MAC xxxxxxxxxxxx IPv6 Network Configuration Enter Configuration Menu Press ENTER to enter configuration menu for IPv6 configuration...

Страница 171: ...DAD Transmit Count The number of consecutive Neighbor Solicitation messages sent while performing Duplicate Address Detection on a tentative address A value of zero indicates that Duplicate Address D...

Страница 172: ...4 New Gateway addresses Gateway IP address can only be configured under manual policy e g 2002 3 Separate the IP address with blank space to configure more than one address New DNS addresses DNS addre...

Страница 173: ...ollow the instructions to initiate the Intel Virtual RAID on CPU function Step 1 Select Advanced Socket Configuration IIO Configuration Socket 1 Configuration IOU3 IIO PCIe Port 4 Select x16 as MB def...

Страница 174: ...http www tyan com 174 Step 3 Save changes and reboot to BIOS Select Advanced to setup Intel Virtual RAID on CPU All Intel VMD Controllers Select to see more information about the Intel VMD Controllers...

Страница 175: ...page may vary in accordance with the cards you installed Intel PRO 1000 8 5 21 PCI E Provides Health Status for the Drivers Controllers Healthy Intel PRO 1000 8 5 21 PCI E Provides Health Status for t...

Страница 176: ...enshot of the Driver Health The information displayed here may vary in accordance with the card you installed Controller 6136CF98 Provides Health Status for the Drivers Controllers Healthy Intel I210...

Страница 177: ...ot of the Driver Health The information displayed here may vary in accordance with the card you installed Controller 61375698 Child 0 Provides Health Status for the Drivers Controllers Healthy Intel I...

Страница 178: ...MD Technology 7 5 0 1152 NOTE This is a sample screenshot of the Driver Health The information displayed here may vary in accordance with the card you installed Controller 612FDB18 Child 0 Provides He...

Страница 179: ...B 2 Timer Policy are available when FRB 2 Timer is set to Enabled FRB 2 Timer timeout Enter value Between 3 to 6 min for FRB 2 Timer Expiration value Not available if FRB 2 Timer is disabled 3 minutes...

Страница 180: ...tchdog Timer is set to Enabled OS Wtd Timer timeout Configure the length of the OS Boot Watchdog Timer Not available if OS Boot Watchdog timer is disabled 5 minutes 10 minutes 15 minutes 20 minutes OS...

Страница 181: ...ed option will not modify any BMC network parameters during BIOS phase Unspecified Static DynamicBmcDhcp DynamicBmcNonDhcp Management Port 2 Enable Disable BMC Share NIC Enabled Disabled Configure IPV...

Страница 182: ...http www tyan com 182 3 4 2 BMC User Settings Add User Press Enter to Add a user Delete User Press Enter to Delete a user Change User Settings Press Enter to change User Settings...

Страница 183: ...ord Enter New Password to change Password at least 8 characters User Access Enable Disable the BMC User s Access Enabled Disabled Channel No Enter BMC Channel Number N A 1 8 User Privilege Limit Enter...

Страница 184: ...http www tyan com 184 3 4 2 2 Delete User User Name Enter BMC User Name User Password Enter New Password to change Password at least 8 characters...

Страница 185: ...ssword at least 8 characters Change User Password Enter New Password to change Password at least 8 characters User Access Enable Disable the BMC User s Access Enabled Disabled Channel No Enter BMC Cha...

Страница 186: ...ord window will pop out to ask for confirmation User Password Set user password in the Create New Password window After you key in the password the Confirm New Password window will pop out to ask for...

Страница 187: ...t Mode Secure Boot mode selector Standard Custom In Custom mode Secure Boot Variables can be configured without authentication Standard Custom Restore Factory Keys Force System to User Mode Install fa...

Страница 188: ...http www tyan com 188 Key Management Enables expert users to modify Secure Boot Policy variables without full authentication...

Страница 189: ...ry Keys Force System to User Mode Install factory default Secure Boot key databases Press Yes to proceed No to cancel Reset to Setup Mode Delete all Secure Boot key database from NVRAM Deleting all va...

Страница 190: ...SA2048 bin d EFI_CERT_SHAXXX 2 Authenticated UEFI Variable 3 EFI PE C0FF Image SHA256 Key source Factory External Mixed Details Export Update Delete Key Exchange Keys Enroll Factory Defaults or load c...

Страница 191: ...oll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER c EFI_CERT_RSA2048 bin d EFI_CERT_SHAXXX 2 Authenticated UEFI Variable 3 EFI...

Страница 192: ...onds to wait for setup activation key 65535 0xFFFF means indefinite waiting 1 Bootup NumLock State Select the keyboard NumLock state Off On Quiet Boot Enable or disable Quiet Boot option Enabled Disab...

Страница 193: ...ESC If Error Wait for ESC key to be pressed if error occurs Enabled Disabled Boot Option Priorities Boot Option 1 4 Select the system boot order Device Name Disabled Delete Boot Option Remove an EFI b...

Страница 194: ...http www tyan com 194 3 6 1 Delete Boot Option Delete Boot Option Remove an EFI boot option from the boot order Select one to delete Device Name...

Страница 195: ...it Exit system setup without saving any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Sa...

Страница 196: ...Defaults Restore Load Default values for all the setup options Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup opt...

Страница 197: ...4 1 Flash Utility Every BIOS file is unique for the motherboard it was designed for For Flash Utilities BIOS downloads and information on how to properly use the Flash Utility with your motherboard pl...

Страница 198: ...0xD0 0xDF DXE errors 0xE0 0xE8 S3 Resume PEI 0xE9 0xEF S3 Resume errors PEI 0xF0 0xF8 Recovery PEI 0xF9 0xFF Recovery errors PEI Standard Checkpoints SEC Phase Status Code Description 0x00 Not used Pr...

Страница 199: ...mory South Bridge initialization South Bridge module specific 0x1B Pre memory South Bridge initialization South Bridge module specific 0x1C Pre Memory South Bridge initialization South Bridge module s...

Страница 200: ...Memory initialization error SPD reading has failed 0x52 Memory initialization error Invalid memory size or memory modules do not match 0x53 Memory initialization error No usable memory detected 0x54 U...

Страница 201: ...ialization CPU module specific 0x66 CPU DXE initialization CPU module specific 0x67 CPU DXE initialization CPU module specific 0x68 PCI host bridge initialization 0x69 North Bridge DXE initialization...

Страница 202: ...Enumeration 0x95 PCI BUS Request Resources 0x96 PCI Bus Assign Resources 0x97 Console Output devices connect 0x98 Console Input devices connect 0x99 Super IO initialization 0x9A USB initialization is...

Страница 203: ...are not available 0xD4 PCI resource allocation error Out of Resources 0xD5 No Space for Legacy Option ROM 0xD6 No Console Output Devices are found 0xD7 No Console Input Devices are found 0xD8 Invalid...

Страница 204: ...Code Description 0x40 System is waking up from the S4 sleep state 0xAC System has transitioned into ACPI mode Interrupt controller is in PIC mode 0xAA System has transitioned into ACPI mode Interrupt...

Страница 205: ...nt shall Tyan be liable for direct indirect incidental special or consequential damages arising from the BIOS update or recovery The BIOS Recovery file is named xxxx cap where the xxxx portion is the...

Страница 206: ...t the server during the BIOS recovery process This can damage the BIOS recovery bootloader and prevent it from loading a subsequent time 7 Wait for the BIOS recovery procedure to complete Completion i...

Страница 207: ...rd A table of BIOS Temp sensor name explanation is also included for readers reference Figure 1 Sensor Location NOTE The red spot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is l...

Страница 208: ...http www tyan com 208 BIOS Temp Sensor Name Explanation...

Страница 209: ...http www tyan com 209...

Страница 210: ...rature of CPU0 DIMM Channel G P0_MC3_DIM_CH_H Temperature of CPU0 DIMM Channel H P1_MC0_DIM_CH_A Temperature of CPU1 DIMM Channel A P1_MC0_DIM_CH_B Temperature of CPU1 DIMM Channel B P1_MC1_DIM_CH_C T...

Страница 211: ...http www tyan com 211 PSU0_FAN Fan Speed of PSU0 PSU1_STATUS Current status of PSU1 PSU1_Temp Temperature of PSU1 PSU1_FAN Fan Speed of PSU1...

Страница 212: ...http www tyan com 212 NOTE...

Страница 213: ...tch Installation This section provides a step by step demonstration on how to install a M 2 latch 1 Take out the M 2 latch packs from the Accessory Box 2 Insert the M 2 latch into the hole and then tu...

Страница 214: ...http www tyan com 214 NOTE The arrow sign on the blue knob is now turned left 3 Push the blue knob slightly to the left as the arrow shows to lock the M 2 card in place...

Страница 215: ...http www tyan com 215 4 The installation of the M 2 latch is now complete...

Страница 216: ...http www tyan com 216 NOTE...

Страница 217: ...serial and parallel ports are built in Bandwidth refers to carrying capacity The greater the bandwidth the more data the bus phone line or other electrical path can carry Greater bandwidth results in...

Страница 218: ...ight bits of a byte of data along one wire and receives data on another single wire that is the data is transmitted in serial form one bit after another Parallel ports transmit the bits of a byte on e...

Страница 219: ...ware that controls the system hardware Form factor an industry term for the size shape power supply type and external connector type of the Personal Computer Board PCB or motherboard The standard form...

Страница 220: ...aster than the ISA bus Local buses are those which operate within a single system as opposed to a network bus which connects multiple systems PCI PIO PCI Programmable Input Output modes the data trans...

Страница 221: ...it can keep two sets of memory addresses open simultaneously By transferring data alternately from one set of addresses and then the other SDRAM cuts down on the delays associated with non synchronou...

Страница 222: ...oard or joystick port It is fast enough to support video transfer and is capable of supporting up to 127 daisy chained peripheral devices VGA Video Graphics Array the PC video display standard V SYNC...

Страница 223: ...prehensive compatibility reports for chassis memory and much more With all these convenient resources just a few keystrokes away users can easily find the latest software and operating system componen...

Страница 224: ...ed by turning the equipment off and on the user is encouraged to try one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and...

Отзывы: