http://www.TYAN.com
40
Intel
®
Xeon
®
processor E5-2600/4600 product families UDIMM Support
1.35V 1.50V
Ranks Per DIMM &
Data Width
Memory Capacity per DIMM
1DPC
2DPC
1DPC
2DPC
SRx8 Non-ECC
1 GB
2GB
4GB N/A N/A
1066,
1333
1066,
1333
DRx8 Non-ECC
2GB
4GB
8GB N/A N/A
1066,
1333
1066,
1333
SRx16 Non-ECC
512 MB
1GB
2GB N/A N/A
1066,
1333
1066,
1333
SRx8 ECC
1GB
2GB
4GB 1066
1066
1066,
1333
1066,
1333
DRx8 ECC
2GB
4GB
8GB 1066
1066
1066,
1333
1066,
1333
NOTE 1:
The blue blocks indicate that the DRAM Densities are supported but not validated.
NOTE 2:
The grey blocks indicate that the DRAM Densities are supported and validated.
NOTE 3:
1DPC => One dimm per channel
NOTE 4:
2DPC => Two dimm per channel
z
Supported DRAM Densities are 1Gb, 2Gb and 4Gb. Only 2Gb and 4Gb are validated
by Intel.
z
Command Address Timing is 1N for 1DPC and 2N for 2DPC.
z
Romley-EP/EX platform does not support 3DPC when using UDIMMs.
Intel
®
Xeon
®
processor E5-2600/4600 product families LRDIMM Support
1.35V 1.50V
Ranks Per DIMM &
Data Width
Memory Capacity per
DIMM
1DPC
2DPC
1DPC 2DPC
QRx4 (DDP)
16GB
32GB 1066
1066
1066,
1333
1066,
1333
QRx8 (P)
8GB
16GB 1066
1066
1066,
1333
1066,
1333
NOTE:
The blue blocks indicate that the DRAM Densities are supported and not validated.
z
Physical Rank is used to calculate DIMM Capacity.
z
Supported and validated DRAM Densities are 2Gb and 4Gb.
z
Command Address Timing is 1N.
z
The speeds are estimated targets and will be verified through simulation.
z
For 3SPC/3DPC -Rank Multiplication (RM) >= 2.
z
DDP -Dual Die Package DRAM stacking. P –Planer monolithic DRAM Die.
z
Romley-EP/EX platform does not support 3DPC when using E5-2400 LRDIMMs.
Содержание S7065
Страница 10: ...http www TYAN com 10 NOTE...
Страница 13: ...http www TYAN com 13 2 2 Block Diagram S7065 Block Diagram...
Страница 18: ...http www TYAN com 18 PSMI1 USB2 FPIO1 USB1 J176...
Страница 20: ...http www TYAN com 20 2PHD_1 J177 J178 KEY_1 3PHD_3 3PHD_2 3PHD_1...
Страница 24: ...http www TYAN com 24 3PHD_4 3PHD_5 3PHD_8...
Страница 26: ...http www TYAN com 26 4PHD_11 SGPIO3 SGPIO1 SGPIO2 DBG HD1...
Страница 61: ...http www TYAN com 61 3 6 5 1 Socket0 CPU Configuration Read only...
Страница 62: ...http www TYAN com 62 3 6 5 2 Socket1 CPU Configuration Read Only...
Страница 67: ...http www TYAN com 67 3 6 8 SAS Configuration Read only...
Страница 71: ...http www TYAN com 71 3 6 12 Hardware Health Configuration...
Страница 73: ...http www TYAN com 73 3 6 13 Super I O Configuration Super IO Chip Read only...
Страница 87: ...http www TYAN com 87 3 7 1 3 DIMM Information Submenu Read only...
Страница 91: ...http www TYAN com 91 3 7 4 ME Sub Menu ME Subsystem Me subsystem Help Enabled Disabled Default is Enabled...
Страница 97: ...http www TYAN com 97 3 11 Event Logs...
Страница 108: ...http www TYAN com 108 BIOS Temp Sensor Name Explanation...
Страница 110: ...http www TYAN com 110 NOTE...