6 of 8
496350 Issue 1
Figure 4. Inside the 1084.
Figure 5. Jumper Link Settings.
2.
Fit link across Microwave jumper pins.
3.
Apply power to the detector and refit cover.
4.
Stand outside the protected area and wait for the Alarm LEDs to go out.
5.
Walk into the protected area and stop when the Alarm LEDs illuminate.
Mark the position carefully.
6.
Repeat steps 4 and 5 throughout the protected area unit the complete
microwave surveillance pattern has been mapped.
7.
If necessary adjust the Microwave range potentiometer to obtain the
desired surveillance pattern.
Adjusting the Surveillance Pattern