4 of 8

496350 Issue 1

LED Indicators

5 LEDs.
2 x Red - Alarm/Test/Trouble.
2 x Green - PIR.
1 x Yellow - M/W.

Mounting

Flat ceiling mounting. (Flush Mount Kit available).

Physical

Dia. x Depth 120 x 55mm.

Approval

DTI Spec. MPT1349.

Warranty

5 years.

Recommended mounting height is between 2.4m and 4.6m (Figure 2). Avoid
heights in excess of 4.6m as the detection sensitivity declines to an inadmis-
sible level.

Figure 2. Graph of Range vs Mounting Height (see Fig 1 for a, b and c)

Specification subject to change at any time.

Wiring Connections

1.

Ensure that the wiring has no power applied.

2.

Connect terminals 1, 2 and/or 3 to the control panel or warning device,
depending on circuit requirements.

3.

Connect terminal 4 to the positive supply.

4.

Connect terminal 5 to the 0V supply.

5.

Use Terminal 6 (EOL) as a connection point for EOL devices.

6.

If the control panel has a 0V Test facility, connect terminal 7 (Test) to
the control panel Test connection. If connected the ‘Walk Test’ LEDs
will be enabled only when ‘Walk Test’ is selected at the control panel. If
no Test facility is available at the control panel, a switch can be used to
switch the 0V supply to terminal 7.

Wiring Connections

1084

Содержание 1084

Страница 1: ...496350 Issue 1 1 of 8 1084 Installation Guide Compatible Equipment All Hardwired Control Panels for example 9800 8 16 zone control panel 808 8 12 zone control panel 816 8 16 zone control panel ...

Страница 2: ...ector for use in wired intruder alarm systems and is suitable for commercial burglar alarm systems The 1084 Twintec combines both Microwave and Passive Infra Red PIR technologies in a single small detector giving a conical surveillance area as shown in Figure 1 Figure 1 Detector Surveillance Area 1084 ...

Страница 3: ...upply Voltage 8 15V DC Current 20mA Relay Output SPCO 30V 100mA DC Change over in alarm with 22ohm resistor in series Tamper Output SPST 30V 100mA DC Closed with cover on Detection Pattern Conical see Figure 1 Operating Temp 10 C to 55 C MW Range Adjustable100 30 by potentiometer Microwave Dielectric Resonant Oscillator with microstrip antenna 10 687 GHz Infra Red Sensor Dual element pyroelectric ...

Страница 4: ... to change at any time Wiring Connections 1 Ensure that the wiring has no power applied 2 Connect terminals 1 2 and or 3 to the control panel or warning device depending on circuit requirements 3 Connect terminal 4 to the positive supply 4 Connect terminal 5 to the 0V supply 5 Use Terminal 6 EOL as a connection point for EOL devices 6 If the control panel has a 0V Test facility connect terminal 7 ...

Страница 5: ...ern of both the microwave and PIR sensors must be adjusted to suit the protected area To check the actual coverage of the detector place links on the appropriate jumper links as described below for each function then walk test the protected area Note A walk test can be carried out on either the microwave sensor or the PIR sensor or both detectors simultaneously Microwave Pattern Adjustment The det...

Страница 6: ...ea and wait for the Alarm LEDs to go out 5 Walk into the protected area and stop when the Alarm LEDs illuminate Mark the position carefully 6 Repeat steps 4 and 5 throughout the protected area unit the complete microwave surveillance pattern has been mapped 7 If necessary adjust the Microwave range potentiometer to obtain the desired surveillance pattern Adjusting the Surveillance Pattern 1084 ...

Страница 7: ... mounting the detector less than 2 4m high Setting The Operational Mode When the surveillance pattern has been set up for both microwave and PIR sensor and any necessary masking has been done the operational mode of the detector must be set Setting The Walk Test Mode With a link fitted across the Test terminals the alarm LEDs will indicate movement at all times However where Alarm LED illumination...

Страница 8: ... mode has been selected the operation of the complete detector should be tested as follows 1 Select Walk Test if applicable 2 Clear the protected area and make four random direction walk tests Walk at a rate of one normal step per second within the detection pattern The unit should alarm within three out of the four walk tests 3 Stand outside the protected pattern and operate any potential cause o...

Отзывы: