Twin-Star International DFS-450 Скачать руководство пользователя страница 5

FIREPLACE   LOCATION

When choosing a location for your new fireplace,

ensure that the general instructions are followed. 

Also, for best effect, install the fireplace out of 

direct sunlight.

                   

                        Cold climate installation recommendation: 

                        when installing this unit against a 

                        non-insulated exterior wall or chase, it is

                        mandatory that the outer walls be insulated

                        to conform to applicable insulation codes.

ELECTRICAL CONNECTION

A 15 AMP, 120 Volt, 60 Hz circuit with a 

properly grounded outlet is required. Preferably, the

fireplace will be on a dedicated circuit as other 

appliances on the same circuit may cause the circuit

breaker to trip or the fuse to blow when the heater is

in operation. The unit comes standard with 6 feet 

(1.8 m) three wire cord, exiting from the rear of the

fireplace. Plan the installation to avoid the use of 

an extension cord. If an extension cord must be 

used, it must be a minimum 14 AWG ; three wires

with grounding type plug connector and rated 

not less than 1875 Watts. The cord shall not be

more than 20 feet (6 m) in length.

ELECTRICAL SPECIFICATIONS

Voltage:         120VAC, 60Hz

Amps:            12.5 Amps

Watts:            1500 Watts

CLEARANCE TO COMBUSTIBLES

Keep electrical cords, drapery, furniture and other 

combustibles at least 3 feet (0.9 m) from the front of the 

heater and away from the sides.

CLEANING TRIM

Clean the metal trim using a soft cloth, slightly 

dampened with citrus oil based product and buff with 

a clean soft cloth. DO NOT use brass polish or 

household cleaners as these products will damage 

the metal trim. Citrus oil based products can be 

obtained at supermarkets or hardware stores.

MAINTENANCE

The motors used on the fan and the flame generator assembly are pre-lubricated for extended bearing life and 

require no further lubrication. However, periodic cleaning/vacuuming of the fan/heater unit is recommended. 

Make sure the unit is turned OFF and unplugged whenever you are cleaning the heater or fireplace.

WARNING: Make sure the power is turned off before proceeding. Any electrical repairs or 

re-wiring of this unit should be carried out by a licensed electrician in accordance with 

national and local codes.

If repairing or replacing any electrical component or wiring, the original wire routing, color 

coding and securing locations must be followed.

WARNING: Electrical outlet wiring must comply with local building codes and other applicable

 regulations to reduce the risk of fire, electrical shock and injury to persons.

WARNING: Do not use this fireplace if any part of it has been under water. Immediately call a 

qualified service technician to inspect the fireplace and replace any part of the electrical system.

WARNING: Disconnect power before attempting any maintenance or cleaning to reduce the risk

 of fire, electrical shock or personal injury.

MAINTENANCE

WARNING: During any service of this appliance, the power to the unit must be turned off. 

First turn the main power switch to the “OFF” position. Then remove the electrical plug from 

the wall outlet.

E-4

Meijer.com

Содержание DFS-450

Страница 1: ...para llamadas en ingl s 866 661 1218 L nea para llamadas en espa ol 866 661 1218 L nea para llamadas en franc s 866 374 9203 STOP STOP PARE PARE ATTENTION SI VOUS AVEZ DES PROBL MES OU QUESTIONS ENVOY...

Страница 2: ...in China Printed in China E Mail parts twinstarhome com In English Call 866 661 1218 In French Call 866 374 9203 In Spanish Call 866 661 1218 For Customer Service E 1 V E N T F R E E D E C O R A T I...

Страница 3: ...nadian Electrical Code or for U S A installations follow local codes and the National Electrical Code ANSI NFPA NO 70 17 There is a thermostat limiter inside the heater When the inner temperature over...

Страница 4: ...Motor Located inside the unit Flame Generator Spinner Located inside the unit E 3 Mechanical Thermostat Knob Heater Swtich Main Power Switch PRODUCT ORIENTATION Emberbed Heater Blower Assembly Fig 2 E...

Страница 5: ...buff with a clean soft cloth DO NOT use brass polish or household cleaners as these products will damage the metal trim Citrus oil based products can be obtained at supermarkets or hardware stores MAI...

Страница 6: ...ions and will illuminate the flame effect This switch must be in the ON position for any of the functions to work Press this switch to turn ON or OFF heater output This switch must be in ON position f...

Страница 7: ...Loosen the screw holding the spinner to the spinner motor and then remove the spinner Fig 5 5 Remove light bulbs and replace with clear 120V 40W E12 Socket base light bulbs Fig 6 6 Place rear access p...

Страница 8: ...on 1 Check that the unit is plugged into a standard 120V power outlet 2a Open the back panel of the unit Check whether the spinner spindle was connected to the motor 2b Check whether Flame Generator d...

Страница 9: ...t or otherwise of same will not be covered by this warranty nor shall the Company assume responsibility for same 6 The owner user assumes all other risks if any including the risk of any direct indire...

Отзывы: