MANTEL  LOCATION

When choosing a location for your new fireplace,

 ensure that the general instructions are followed. 

Also, for best effect, install the fireplace out of 

direct sunlight.

                   

                        Cold climate installation recommendation: 

                        when installing this unit against a 

                        non-insulated exterior wall or chase, it is

                        mandatory that the outer walls be insulated

                        to conform to applicable insulation codes.

ELECTRICAL CONNECTION

A 15 AMP, 120 Volt, 60 Hz circuit with a 

properly grounded outlet is required. Preferably, the

fireplace will be on a dedicated circuit as other 

appliances on the same circuit may cause the circuit

breaker to trip or the fuse to blow when the heater is

in operation. The unit comes standard with 6 feet 

(1.8 m) three wire cord, exiting from the rear of the

fireplace. Plan the installation to avoid the use of 

an extension cord. If an extension cord must be

used, it must be a minimum 14 AWG , three wires

        ELECTRICAL SPECIFICATIONS 

Voltage:         120 V~, 60Hz

Amps:            11.7 Amps (with heater)

Amps:            

< 

0.1 Amps (without heater)

Watts:            1400 Watts (with heater)

Watts:            < 10 Watts (without heater)

CLEARANCE TO COMBUSTIBLES

Keep electrical cords, drapery, furniture and other 

combustibles at least 3 feet (0.9 m) from the front of the 

heater and away from the sides.

CLEANING TRIM

Clean the metal trim using a soft cloth, slightly 

dampened with citrus oil based product and buff with 

a clean soft cloth. DO NOT use brass polish or 

household cleaners as these products will damage 

the metal trim. Citrus oil based products can be 

obtained at supermarkets or hardware stores.

MAINTENANCE

The motors used on the fan and the flame generator assembly are pre-lubricated for extended bearing life and 

require no further lubrication. However, periodic cleaning/vacuuming of the fan/heater unit is recommended. 

Make sure the unit is turned OFF and unplugged whenever you are cleaning the heater or fireplace.

WARNING: Make sure the power is turned off before proceeding. Any electrical repairs or 

rewiring of this unit should be carried out by a licensed electrician in accordance with 

national and local codes.

If repairing or replacing any electrical component or wiring, the original wire routing, color 

coding and securing locations must be followed.

WARNING: Electrical outlet wiring must comply with local building codes and other applicable

 regulations to reduce the risk of fire, electrical shock and injury to persons.

WARNING: Do not use this fireplace if any part of it has been under water. Immediately call a 

qualified service technician to inspect the fireplace and replace any part of the electrical system.

Warning: Disconnect power before attempting any maintenance or cleaning to reduce the risk

 of fire, electrical shock or personal injury.

MAINTENANCE

The motors used on the fan and the flame generator assembly are pre-lubricated for extended bearing life and 

require no further lubrication. However, periodic cleaning/vacuuming of the fan/heater unit is recommended. 

Make sure the unit is turned OFF and unplugged whenever you are cleaning the heater or fireplace.

WARNING: Make sure the power is turned off before proceeding. Any electrical repairs or 

rewiring of this unit should be carried out by a licensed electrician in accordance with 

national and local codes.

If repairing or replacing any electrical component or wiring, the original wire routing, color 

coding and securing locations must be followed.

WARNING: Electrical outlet wiring must comply with local building codes and other applicable

 regulations to reduce the risk of fire, electrical shock and injury to persons.

WARNING: Do not use this fireplace if any part of it has been under water. Immediately call a 

qualified service technician to inspect the fireplace and replace any part of the electrical system.

Warning: Disconnect power before attempting any maintenance or cleaning to reduce the risk

 of fire, electrical shock or personal injury.

TROUBLE SHOOTING GUIDE

Warning: During any service of this appliance, the power to the unit must be turned off. 

First turn the main power switch to the “OFF” position. Then remove the electrical plug from 

the wall outlet.

with grounding type plug connector and rated 

not less than 1875 Watts. The cord shall not be

more than 20 feet (6 m) in length. 

Содержание 23EF022GRA

Страница 1: ...nea para llamadas en ingl s 866 661 1218 L nea para llamadas en espa ol 866 661 1218 L nea para llamadas en franc s 866 374 9203 STOP STOP PARE PARE ATTENTION SI VOUS AVEZ DES PROBL MES OU DES QUESTI...

Страница 2: ...33EF022GRA 33EF022SRA ALSO Requires Wood Fireplace Mantel V E N T F R E E F I R E P L A C E W I T H H E A T E R Thank you and congratulations on your purchase of a Twin Star International Inc fireplac...

Страница 3: ...th the current CSA C22 1 Canadian Electrical Code or for U S A installations follow local codes and the National Electrical Code ANSI NFPA NO 70 17 There is a thermostat limiter inside the heater When...

Страница 4: ...rt and adjusting bottom of insert could scratch the finish of the base hearth of your fireplace Re attach the mounting brackets with the Phillips head screwdriver and supplied screws DO NOT OVER TIGHT...

Страница 5: ...ed electrician in accordance with national and local codes If repairing or replacing any electrical component or wiring the original wire routing color coding and securing locations must be followed W...

Страница 6: ...setting HEATER Your fireplace consists of a fan forced wire element type heater There are 11 thermostat levels you can cycle through and the OFF or ON settings This button on the remote control only t...

Страница 7: ...ion changed and the level selected by the control panel or remote control When the function is turned off the corresponding indicator will flash 5 times and then fade off Figure 6 on the upper right o...

Страница 8: ...power is set at ON position 4a Adjust the temperature settings to ensure that the thermostat is set higher than the current room temperature 5a Turn the POWER to OFF and unplug the unit from the wall...

Страница 9: ...eplacement or otherwise of same will not be covered by this warranty nor shall the Company assume responsibility for same 6 The owner user assumes all other risks if any including the risk of any dire...

Страница 10: ...i n de una chimenea de Twin Star International Inc Lea las Instrucciones de Instalaci n y Operaci n antes de utilizar este aparato IMPORTANTE Lea todas las instrucciones y advertencias con detenimient...

Страница 11: ...con c digos locales y el C digo Nacional de Electricidad ANSI NFPA N 70 17 El calentador incluye un limitador de termostato Si la temperatura interior aumenta demasiado o se produce un calentamiento...

Страница 12: ...l hogar la base de la chimenea Vuelva a colocar los soportes de montaje con el destornillador Phillips y los tornillos suministrados NO LOS AJUSTE EN EXCESO Con la ayuda de un asistente levante con cu...

Страница 13: ...nte para proporcionar una vida til m s prolongada a los rodamientos y no requieren lubricaci n adicional No obstante se recomienda limpiar aspirar peri dicamente la unidad del ventilador calentador As...

Страница 14: ...nsidad de la llama disminuye Hay cinco niveles de brillo entre los que puede elegir y la opci n de apagado OFF HEATER La chimenea consiste en un calentador tipo elemento de alambre con ventilador Hay...

Страница 15: ...ci n desde el panel de controles o el control remoto aparece el indicador correspondiente vea la figura 6 en la esquina superior derecha de la pantalla de proyecci n El indicador muestra la funci n qu...

Страница 16: ...los valores de temperatura para asegurar que el termostato se fija m s que la temperatura ambiente actual 5a Coloque el bot n POWER Energ a en la posici n OFF y desenchufe la unidad del tomacorriente...

Страница 17: ...gos si los hay que incluyen el riesgo de cualquier p rdida Para obtener las actualizaciones y revisiones de este manual visite nuestro sitio Web www twinstarhome com instructions Comun quese con la co...

Страница 18: ...T E A V E C C H A U F F E R E T T E Merci et f licitations d avoir achet ce po le Twin star Veuillez lire les instructions d installation et d utilisation avant de mettre en marche cet appareil IMPOR...

Страница 19: ...conform ment la derni re dition de la norme CSA C22 1 du Code canadien de l lectricit ou si le produit est install aux tats Unis aux codes locaux et la norme ANSI NFPA 70 du National Electrical Code 1...

Страница 20: ...oyer Revisser les supports de fixation avec le tournevis pointe cruciforme et les vis fournies cet effet NE PAS SERRER EXCESSIVEMENT LES VIS Avec l aide d un assistant soulever d licatement l unit ass...

Страница 21: ...de chauffage S assurer que l unit est en position ARR T et d branch e au moment de nettoyer le l appareil de chauffage ou le foyer Recommandation pour l installation en climat froid lorsque l unit est...

Страница 22: ...luminosit ainsi que la mise l arr t OFF peuvent tre s lectionn s de mani re cyclique sur le panneau CHAUFFERETTE Le foyer consiste en une chaufferette l ments lectriques air puls Onze niveaux de temp...

Страница 23: ...nne sur le mat riel brouilleur NMB 003 LIMINATION DES PILES USAG ES REMPLACEMENT DES PILES DE LA T L COMMANDE Lorsque la t l commande cesse de fonctionner ou si sa port e semble r duite il est temps d...

Страница 24: ...on est r gl e la position ON 4a R glez les param tres de temp rature pour s assurer que le thermostat est fix plus haut que la temp rature ambiante actuelle 5a Mettre le bouton POWER la position OFF e...

Страница 25: ...ant un vice du mat riau ou de fabrication condition que ces pi ces aient t soumises des conditions normales d utilisation et de service et apr s que le pr tendu vice ait t confirm par l inspection d u...

Страница 26: ...nea para llamadas en ingl s 866 661 1218 L nea para llamadas en espa ol 866 661 1218 L nea para llamadas en franc s 866 374 9203 STOP STOP PARE PARE ATTENTION SI VOUS AVEZ DES PROBL MES OU DES QUESTI...

Отзывы: