5
1.4 How to choose fuel type
In the
settings
menu
under
fuel type
you can choose between 4 programs
There are 3 fixed programs for respectively
Wood pellets, Grains or Wood chips
.
The programs are adapted to the individual type of fuel.
If you choose to use another kind of fuel than the above mentioned, you have the
possibility to choose
Other
under
fuel type
. When
Other
has been chosen,
parameters for this fuel must be adjusted.
(See section
1.6
Setting)
The cursor must be placed by the line
Setting
Press
to choose
setting
Press
to
Fuel type
The chosen fuel type is shown. (e.g.
Pellets
)
Press
Now the type of fuel can be changed by pressing
Confirm the new setting with
Leave the menu by pressing
PLEASE NOTE:
Requirements when heating with grains: High flue gas temperature min. 180°C
High boiler output min. 50%
High boiler temperature min. 80°C
1.5 O2 regulation ore manual operation
Manual operation can be an advantage, if the fuel used is of bad quality or if e.g. the
lambda probe goes defect
The cursor must be placed by the line
Setting
Press
to choose
setting
Press
to
O2 regul. On/off
Press
to choose
O2 regulator menu
Press
: Now you can choose
YES
or
NO
by pressing
.
(
YES
= O2 regulation
NO
= Manuel operation)
Confirm your choice by pressing
Leave the menu by pressing
Hereafter the
Man. Fac.
(the amount of fuel) has to be adjusted (0 – 100 %)
according to the fuel chosen : pellets, grains, wood chips or other.
(See next section)
1.5.1 Adjustment of Man. Fac. (amount of fuel by manual operation)
In the
O2 regulator menu
under
Man. Fac.
You can adjust the desired amount of
fuel, when using “manuel operation”
Manuel operation can be a good choice, if you use inferior fuel or if e.g. the lambda
probe might be defect.
Section 1 – The control panel