Section 3- Troubleshooting
Possible errors will appear in the upper line in the display.
When the problem has been solved the message
can be annulled by pressuring »START«
Section 3 – Troubleshooting
Before restarting the boiler after any errors, please check, if the sprinkler has sprinkled
water into the auger channel (slow moving auger, fuel is wet)
If this is the case, use the auger to transport the wet fuel into the combustion room and
remove it from here (Remove fuel manually from the burner tube)
After removing the fuel please check that the sprinkler valve is closing tight again – See
section 3.8 sprinkler
3.1 Open lid
The fuel store lid is open or has not been properly closed
The release handle for the fuel store has not been properly tightened
The fuel store has been pulled back
3.2 Error: Hot boiler
The boiler temperature has exceeded 95 ºC and the over temperature thermostat has
stopped the boiler.
The produced amount of heat could not be used in the heating system.
Causes:
There is no real need for heat (typical for the summer).
There might be an air pocket in the system, no water circulation.
The circulation pump does not function.
When the boiler temperature has fallen below 80 – 85 ºC and the error has been
corrected, reset over temp. thermostat and restart the boiler.
Reset the over temp. thermostat by removing the black hood on top of the boiler and
gently press a match or the like into the hole. Put black hood in place again.
Should the fuel still be glowing in the burner tube, press »START« and the boiler will
restart as described in section 2.4, soft start.
In case the fire should be extinguished, you must start the fire again as described in
section 2.2 “Taking fuel forward to the burner tube”
Low temp. (start)
Temperature : 33,8
o
C
O2 Auto : 20,9 %
O2 wanted : 8,0 %