47
Reducing the Noise (FILTER)
0
20
40
60
80
100
120
140
0
20
40
60
80
100
120
140
10
100
1000
10000
Example of frequency property when a
fi
lter is used
Measured
value [V]
Filter OFF
Passband 500 [Hz]
Passband 100 [Hz]
(AC voltage 600.0 V range, 100 V input)
Frequency at 100 V input (Hz)
Example: Power frequency on an aircraft or marine vessel is
400 Hz
When voltage is 100 V
FILTER setting
Displayed value
Normal
OFF
Approx. 100 V
500 Hz
Abnormal
100 Hz
Around 0 V