MFC710/AcR - Section: 2. Mechanical dimensions
Table 2.1: Dimensions of the
MFC710/AcR
690V
frequency converters
(replaces the table 0.3b in the MFC710 user's manual)
Modification Type of a converter
Dimensions
[mm]
a
A
b
B
C
d1
d2
Ø1
Ø2
φ
Weight
1)
[kg]
B
45
55
Casings are chosen according to the individual requirements.
75 kW
90 kW
838
865
190
283
400
12
15
8,5
8,5
18
65
110 kW
132 kW
160kW
200kW
875
920
338
460
345
15
25
13
13
22
100
250kW
315kW
355kW
875
920
940
2)
420
558
3)
640
345
15
25
13
13
22
130
400kW
450kW
500kW
1045
1090
1127
2)
2x317
800
345
15
25
13
13
22
200
560kW
630kW
800kW
Cabinet construction
1. Approximate weight of a frequency converter, may vary depending on its construction.
2. Height of a frequency converter increased due to due to protruding rails for power and load connection.
3. Bottom spacing of mounting holes.
4. In version A, we use two identical casings placed next to each other.
We also offer MFC710 / AcR converters in a cabinet version with a selected degree of IP protection
according to individual customer requirements.
TWERD POWER ELECTRONICS
7