background image

© 2011 Thermadyne Industries, Inc.

www.thermadyne.com 

Printed in U.S.A.

W O R L D   H E A D Q UA R T E R S:

16052 Swingley Ridge Road, Suite 300 • St. Louis, Missouri 63017  U.S.A.

A Global Cutting & Welding Market Leader

U.S. Customer Care:

ARCAIR

®

 / STOODY

®

 / THERMAL ARC

®

 / THERMAL DYNAMICS

®

 / 

TWECO

®

 / VICTOR

®

.............................

800-426-1888 / 

FAX 

800-535-0557

FIREPOWER

®

.......................................

800-858-4232 / 

FAX 

800-535-0557

TURBOTORCH

®

.....................................

800-238-0282 / 

FAX 

800-535-0557

TDC AUTOMATION

................................

866-279-2628 / 

FAX 

800-535-0557

VICTOR MEDICAL

.................................

800-382-8187 / 

FAX

 800-535-0557

VICTOR SPECIALTY PRODUCTS

...........

800-569-0547 / 

FAX 

800-535-0557

Canada Customer Care:  905-827-4515 / 

FAX 

800-588-1714

International Customer Care:  940-381-1212 / 

FAX 

940-483-8178 

CIGWELD Customer Care:  1300-654-674 / 

FAX 

 61-3-9474-7391  

www.thermadyne.com

THE AMERICAS

Denton, TX  USA

U.S. Customer Care

Ph:  1-800-426-1888 (tollfree)

Fax: 1-800-535-0557 (tollfree)

Miami, FL  USA

Sales Office, Latin America 

Ph: 1-954-727-8371

Fax: 1-954-727-8376

Oakville, Ontario, Canada

Canada Customer Care

Ph: 1-905-827-4515

Fax: 1-800-588-1714 (tollfree)

International Customer Care

Ph: 1-940-381-1212

Fax: 1-940-483-8178

EUROPE

Chorley, United Kingdom

Customer Care

Ph:  +44 1257-261755

Fax: +44 1257-224800

Milan, Italy

Customer Care 

Ph:  +39 0236546801

Fax: +39 0236546840

ASIA / PACIFIC

Cikarang, Indonesia

Customer Care

Ph:  6221-8990-6095

Fax: 6221-8990-6096

Rawang, Malaysia

Customer Care 

Ph:  +603 6092-2988

Fax: +603 6092-1085

Melbourne, Australia

Australia Customer Care 

Ph:  1300-654-674 (tollfree)

Ph: 61-3-9474-7400

Fax: 61-3-9474-7391

Shanghai, China

Sales Office

Ph:  +86 21-64072626

Fax: +86 21-64483032

Singapore

Sales Office 

Ph:  +65 6832-8066

Fax: +65 6763-5812

International

Ph: 61-3-9474-7508

Fax: 61-3-9474-7488

89210007 Rev. A

Printed in China

Содержание Spool gun

Страница 1: ...Issue Date April 20 2012 Manual No 89210007 Revision A Safety and Operating Instructions SPOOL GUN English...

Страница 2: ...help you to avoid potential hazards that may exist when working with this product YOU ARE IN GOOD COMPANY The Brand of Choice for Contractors and Fabricators Worldwide Tweco is a Global Brand of Arc...

Страница 3: ...enton TX 76208 940 566 2000 www thermadyne com U S Customer Care 800 426 1888 International Customer Care 940 381 1212 Copyright 2011 2012 Thermadyne Industries Inc All rights reserved Reproduction of...

Страница 4: ...ing wire feed pressure and speed 3 8 3 03 Installing the wire spool 3 8 SECTION 4 CARE AND MAINTENANCE 4 11 4 01 Changing the contact tip 4 11 4 02 Changing the wire conduit 4 12 4 03 Changing the dri...

Страница 5: ...ctrical path All ground connections must be checked periodically to determine if they are mechanically strong and electrically adequate for the required current When engaged in AC welding cutting unde...

Страница 6: ...e flying sparks hot slag and heated materials can cause fire and explosions Remove combustibles from the work area and or provide a fire watch Avoid oily or greasy clothing as a spark may ignite them...

Страница 7: ...ion American National Standards Institute 1430 Broadway New York NY 10018 5 AWS F4 1 Recommended Safe Practices for Welding and Cutting Containers 6 AWS C5 3 Recommended Practices for Air Carbon Arc G...

Страница 8: ...1 4 SET UP AND SAFE OPERATING PROCEDURES 89210007 This Page Intentionally Blank...

Страница 9: ...ating Rated Welding Current C02 160A Duty Cycle 20 Wire Diameter Normal 0 023 0 035 Normal Wire Diameter Stainless Steel 0 023 0 030 Stainless Steel Maximum Wire Feed Speed 630 in min 16 m min Maximum...

Страница 10: ...2 6 SET UP AND SAFE OPERATING PROCEDURES 89210007 This Page Intentionally Blank...

Страница 11: ...ting the welding gun 2 Insert the gun connection into the feeder receptacle aligning the conduit plug first then the gas plug Push until all fittings are seated then tighten the nut hand tight 3 Conne...

Страница 12: ...lockwise to decrease or counterclockwise to increase pressure on the wire feed drive rolls 2 Adjust the AMP Wire Feed Speed knob on the power supply to adjust the wire speed feed Direction Result Cloc...

Страница 13: ...onto the shaft 3 Press the red button on top of the gun to release pressure from the drive rolls 4 Push the wire through the guide and into the wire feed drive rolls 5 Make sure the welding power sou...

Страница 14: ...nto the conductor tube and cut the wire to obtain the correct wire stick out 7 Adjust the friction nut on the spool shaft to apply the correct wire tension Spool should stop when trigger is released 8...

Страница 15: ...med 1 Select the correct contact tip according to the wire used 2 Remove the nozzle from the gun to reveal the contact tip 3 Remove the contact tip using pliers if needed Replace contact tip and tight...

Страница 16: ...UIT NOTE Replace liner if hole is obstructed Make sure the end of the liner is smooth 1 Turn the power source OFF and disconnect the gun 2 Unscrew the nozzle and remove it from the conductor tube 3 Re...

Страница 17: ...ING THE DRIVE ROLLS NOTE Turn power supply OFF before replacing drive rolls 1 Remove the screws which secure the upper and lower drive rolls It may be necessary to remove drive roll side of gun case t...

Страница 18: ...holding each drive roll in place Press the red button on top of the gun to relieve pressure on the rolls if necessary Remove the drive rolls and install the new drive rolls in reverse order 4 Perform...

Страница 19: ...until the wire feeds properly or doesn t slip See page 3 6 Worn or dirty drive rolls Clean or replace drive rolls Incorrect wire spool friction Adjust the friction nut on the spool shaft to find the...

Страница 20: ...023 0 6 mm 1110 1101 11 30 Contact Tip 030 10 8 mm 1110 1102 11 35 Contact Tip 035 10 9 mm 2 1210 1300 21T 37 Nozzle 3 8 9 5 mm 1210 1100 21 37 Nozzle 3 8 9 5 mm 1210 1110 21 50 Nozzle 1 2 12 7 mm 12...

Страница 21: ...Assembly 2031 2250 WSPDRU023 023 Drive RollAssembly U Shaped Smooth 2031 2251 WSPGRU023 023 Guide RollAssembly U Shaped Smooth 2031 2252 WSPDRU035045 035 Drive RollAssembly U Shaped Smooth 2031 2253 W...

Страница 22: ...6 18 This Page Intentionally Blank...

Страница 23: ...ion The remedies of the Purchaser set forth herein are exclusive and the liability of THERMADYNE with respect to any contract or anything done in connection therewith such as the performance or breach...

Страница 24: ...ICAS Denton TX USA U S Customer Care Ph 1 800 426 1888 tollfree Fax 1 800 535 0557 tollfree Miami FL USA Sales Office Latin America Ph 1 954 727 8371 Fax 1 954 727 8376 Oakville Ontario Canada Canada...

Отзывы: