ARCMASTER 401S POWER SOURCE
POWER SOURCE PROBLEMS AND ROUTINE SERVICE REQUIREMENTS 5-2 Manual 0-5345
5.02 Power Source Status Messages
An error code is displayed in the digital displays in the event of a malfunction. You can switch over between error
code and sub-error (sub code) in the digital displays by pressing Process Selection Button.
After the message has been displayed, the machine will only function to a limited extent; the error must be cor-
rected as quickly as possible.
The status message can be deleted by pressing Encoder Control.
Code
Note
Cause
Possible Remedy
H08
Short-circuit
Short-circuit in the output circuit
Eliminate the short-circuit (pick up
electrode holder, ...)
H30
Configuration
Component group recognition faulty Take to an accredited Tweco Service
Center for repair
Table 5-1 Power Source Status Messages
5.03 Error Messages
!
WARNING
There are extremely dangerous voltage and power levels present inside this Inverter Power Source.
Do not attempt to open or repair unless you are an accredited Tweco Service Provider. Disconnect the
Welding Power Source from the Mains Supply Voltage before disassembling.
An error code is displayed in the digital displays in the event of a malfunction. You can switch over between error
code and sub-error (sub code) in the digital displays by pressing any button. As long as there is an error code
on display welding is not possible.
Code
Error
Cause
Possible Remedy
E01
Excessive Temperature
Duty cycle exceeded
Allow switched-on machine to cool
down for a few minutes
Dust filter contaminated
Replace dust filter
E02
Overvoltage
Mains voltage too high
Check mains voltage
E06
Overvoltage Secondary
Initial voltage too high
Take to an accredited Tweco Service
Center for repair
E07
EEPROM
Communication with EEPROM
defec tive
Switch machine off and on again,
ex ecute master reset
E08-1
Excess Wirefeeder Voltage
Wirefeeder voltage too high
Take to an accredited Tweco Service
Center for repair
E08-2
Wirefeeder Motor
Error in Wirefeeder Motor
Take to an accredited Tweco Service
Center for repair
E08-3
Overcurrent on Wirefeeder
Wirefeeder current continu-
ously too high
Reduce motor load
E08-10
Torch Connection
Torch/torch connection error
Check torch and torch connection.
Switch the equipment off and on
again
E08-11
V/I Acquisition
Voltage/current measuring
systems faulty
Take to an accredited Tweco Service
Center for repair
E08-13
CAN Identification
Unknown device connected
Check connected devices and CAN
connections
Содержание ARCMASTER 401S
Страница 6: ...This Page Intentionally Blank...
Страница 14: ...ARCMASTER 401S POWER SOURCE SAFETY INSTRUCTIONS AND WARNINGS 1 8 Manual 0 5345 This Page Intentionally Blank...
Страница 20: ...ARCMASTER 401S POWER SOURCE INTRODUCTION 2 6 Manual 0 5345 This Page Intentionally Blank...
Страница 54: ...ARCMASTER 401S POWER SOURCE This Page Intentionally Blank BASIC WELDING GUIDE 4 16 Manual 0 5345...