TVILIGHT CITYSENSE PLUS Series Скачать руководство пользователя страница 2

Copyrights Tvilight B.V.   September 2017. Datasheet is subject to change without notice.

Product

Motion detection

Input voltage
Power consumption
DALI loads
Dimming control
Surge protection
Controller
Electrical protection

Electrical safety
Operating conditions

Product mounting
Housing
Antenna
Dimensions

Product compatibility

Wireless communication

Network security
Over-the-air update

Server communication
Device to Gateway ratio
Remote monitoring

Safety mode

Certification

Manufacturing

Lamp switching capacity
AstroClock

Warranty

Application

Motion detection sensor, wireless communication and lighting control integrated 
into one product for a simple plug-and-play installation. 
Includes a 5,5m pre-connected power and control cable.
Detects pedestrians, cyclists, and cars (range: 4-120 km/h)
Range: up to 15 m on each side, 9 m in front, 3 m behind
Detection angle: >270 ° (depending on pole diameter)
Triggering of 1-10 neighboring lamps upon detection (user configurable)

230 VAC or 115 VAC, 50/ 60 Hz (depending on variant)
<3W
Max.1
0-10 V or DALI
110 joules (6 Ka), 2 kV combination wave
ARM Cortex-M3 CPU 
Class II (Overload and short-circuit protection)

Galvanic isolation between high-voltage and low-voltage terminals
-20°C to +60°C operating; -40°C to +85°C storage; 20% to 90%, Rh non-
condensing
On the pole. Recommended mounting height 5m above the road surface
IP65, UL94V0 
Integrated Internally
100 mm x 125 mm x 95 mm
+/- 10 ° adjustable mounting plate to accommodate for pole tilts

Direct wireless communication with CitySense and Gateway, communication with 
CityManager: through Gateway
Compatible with conventional (PLL, HID, HPS) and LED luminaires.

2.4 GHz IEEE 802.15.4 self-forming, self-healing wireless network
Depending on variant:
+9.5 dBm max. transmit power, -96 dBm receiver sensitivity, up to 150 meter open field range 
or + 22 dBm transmit power, -100 dBm max. receiver sensitivity, up to 1 KM open field range
Up to 250 kbps microcontroller RF data rate 
32-bit microcontroller, 64 kB Flash and 16 kB RAM
128 AES Multi-layer security
Configuration, software as well as firmware can be updated remotely ensuring up-to-date network 
infrastructure
via Gateway 
200:1 
Via CityManager or similar third-party management software. CityManager enables remote 
management, monitoring, control, and configuration of lamps
on individual and group level.
Auto-safe: in a case of network loss, brightness will go to a pre-defined level depending on the 
settings. Astro clock based scheduling is still possible.  
CE, CB, EN61547, EN55015, EN60950-1, EN61347-1/2-11, EN 301 489-1/17, EN 
300 328, RoHS. RF transceiver compliant with US (FCC), Canadian (IC), European (ETSI), and 
Japanese (Telec) standards
ISO 9001:2008, Made in Europe

1400 VA (Relay), 6A max. current.
Battery-backed real-time clock; AstroClock function.
Able to switch on/off the lamps at sunset/sunrise and adjust them seasonally (summer-winter time).
Eliminates the need for conventional photocell

Standard 2 years limited warranty. Extended warranty available. Warranty subject to proper use of installation- and 
application manuals.
Outdoor street lighting, Area lighting

TECHNICAL SPECIFICATIONS 

Keywords: Wireless iSLC, iOLC Radio Frequency (Intelligent Street /Outdoor Lighting Controller RF), Outdoor Wireless Sensor

(CS-PRAI) 230 VAC (PR150868) or 115 VAC (PR151116)

Page 2 of 8

Содержание CITYSENSE PLUS Series

Страница 1: ...previously defined by the user Dynamic lighting reduces energy consumption by up to 80 without compromising public safety and citizen comfort The in built monitoring tools notify users via CityManager about the lighting related faults such as a lamp or ballast failures This greatly reduces the need for expensive visual inspections and enables a reduction of operation and maintenance costs Designed...

Страница 2: ...ion with CityManager through Gateway Compatible with conventional PLL HID HPS and LED luminaires 2 4 GHz IEEE 802 15 4 self forming self healing wireless network Depending on variant 9 5 dBm max transmit power 96 dBm receiver sensitivity up to 150 meter open field range or 22 dBm transmit power 100 dBm max receiver sensitivity up to 1 KM open field range Up to 250 kbps microcontroller RF data rate...

Страница 3: ...mienta tensora Bevestigingsgereedschap 3 x Aufkleber 3 x Sticker 3 x autocollant 3 x adesivo 3 x etiqueta adhesiva 3 x sticker M16 Gummitüllle M16 Rubber Grommet M16 passe câble M16 guarnizione M16 arandela M16 doorvoer Schraubendreher Screw Driver Tournevis Cacciavite Destornillador Schroevendraaier 4X Klemme 4X Terminal 4X Borne 4X Morsetto 4X borne 4X klem www tvilight com No TVI XXXXXXXXXX L N...

Страница 4: ...l not be able to dim the connected armature Default settings of the CITYSENSEis 100 without TVILIGHT network connection Dimming time Systeme Failure Level Power On Level will be automatically set by CITYMANAGER approx 8m approx 3 5m approx 9 5m approx 2 5m approx 17m approx 4m Speed Range Safety instructions The device may only be used for the application area specified this area should be accessi...

Страница 5: ...e dabei einen Schraubendreher zu Hilfe 4 EN Push grommet into hole Use a screw driver to press grommet into the hole 4 FR Pousser le passe câble dans le trou Utiliser un tournevis pour enfoncer le passe câble dans le trou 4 IT Spingere la guarnizione nel foro Usare un cacciavite per spingere la guarnizione nel foro 4 ES Empuje la arandela en el agujero Utilice un destornillador para presionar la a...

Страница 6: ...ur le poteau 7 IT Applicare l adesivo con l ID del prodotto all asta 7 ES Aplique la etiqueta adhesiva de identificación de producto al poste 7 NL Breng een product ID sticker op de pool aan 8 DE Führen Sie die Verbindung gemäß Schaltplan durch 8 EN Connect as shown in wiring diagram 8 FR Connecter le câble comme indiqué sur le schéma de câblage 8 IT Collegare come mostrato nel diagramma di cablag...

Страница 7: ...packaging if still available Ship the RMA items via traceable means to the below address Write the RMA number on at least two 2 outside surfaces of each return package Write RMA number on the Air Waybill or Shipper Allow four 4 weeks turn around time after receipt of RMA by Company 5 4 Address All RMA packages should be shipped to TVILIGHT B V RMA _ _ _ _ _ Westerhaven 13 6th floor 9718 AW Groning...

Страница 8: ...der the warranty terms Also while the warranty terms cover defects in material design and or manufacturing it excludes failures related to battery power supply other wear and tear parts and consumables Client should maintain an adequate stock in case some of the products require replacement 3 Application note 3 1 The product should be used only in conjunction with properly certified such as CE lum...

Отзывы: