21
6.13
Replacing the Door Bellows
(Located in the Door Bridge)
Caution:
Before starting, be sure that there is no pressure in the autoclave
chamber.
1. Open the door.
2. Unscrew and remove the tightening screw (5).
3. Gently pull out the door safety device locking pin (13).
4. It is possible that the washers (7, 10) will be stuck - if so, push
them out by introducing pressurized air through the steam inlet
hole.
5. Reconnect the door device locking pin (13) into a new silicone
bellows (12).
6. Put the silicone bellows (12) and pin (13) into the bellows housing
(14) and replace the washers (7, 10).
7. Reconnect all the above into the door bridge.
8. Re-screw and tighten the tightening screw (5).
9. Test all autoclave cycles.