Tuthill SOTERA SP100-10 Series Скачать руководство пользователя страница 4

Installation (cont’d) 

FIRE AND EXPLOSION HAZARD!  

Sotera SP100-10X-CX-XXX-X (Groundable Air Motor) 

Air Operated Diaphragm 

pumps must 

be grounded for safe and proper operation.  Before operating the pump, be certain it is properly grounded as illustrated below.  Read and understand 
the warnings on page 2 regarding grounding and spark fire hazards.  An improperly grounded pump can be a fire hazard.   

The SP100 

Air Operated Diaphragm 

pump can be grounded through the mounting feet, located on the inlet manifold (Figure 1).  To reduce the risk of 

static spark, ground the pump and all other equipment located in the pumping area.  Ground wires should be of proper size and installed per local and 

national electrical codes. 

Never use a polypropylene or PVDF with non-conductive flammable fluids as specified 
by your local fire protection codes.  Contact your fluid supplier to determine the 
conductivity or resistance of your fluid.     

If there is any static spark or you feel an electrical spark while using this equipment, 

stop the pump immediately!  DO NOT use the equipment until the problem has 
been located and corrected. 

 

If using a conductive pump, use conductive hoses.  If using a non-conductive pump, 

ground the fluid system.  

 

Installation should be planned taking proper ventilation into consideration.  It is 
imperative that adequate fresh air ventilation be provided to prevent the build up of 
flammable, explosive, or toxic fumes from the fluid being pumped.   

Keep the area around pump clean and free of debris, including rags, solvent and 
gasoline.  Do not allow pilot lights or open flames near the work area; keep a fire 
extinguisher close for quick access.    

Ground Point 

Figure 1 

Pump Grounding 

Ventilating Exhaust Air 

Figure 2 

Diaphragm failure will cause the fluid being 
pumped to exhaust with the air.  If pumping 
caustic, explosive, or flammable materials, they 
can be discharged with exhaust air.    

Exhaust air from the pump must be properly routed 
to ensure safe operation.  The exhaust must be 
discharged in a safe place, away from where it 
could harm people, animals, or contaminate food 
preparation areas.  It should also be away from 
any possible sources of ignition.     

It is also important to place the end of the exhaust 
in an appropriate container to contain any liquid 
that may discharge (Figure 2).   

Install an electrically conductive air exhaust hose, connecting the muffler at the  end.  Minimum diameter for the hose is 3/8” ID.  If the hose run will 
exceed 15’, a larger diameter hose is required.  Take care when routing the hose to avoid kinks and sharp bends that may restrict air flow.  

Fluid Pressure Relief Valve 

Some systems may require installation of a pressure relief valve 
at the pump outlet to prevent over pressurization, and possible 
rupture of the pump or hose (Figure 3).   

Thermal expansion of fluid in the outlet line can lead to over 
pressurization, even if the pump is not operating.  Thermal 
expansion can happen when fluid lines, fluid storage containers, 
and pumps are exposed to sunlight or ambient heat.  It can also 
occur when pumping fluid from a cool area (underground storage 
containers for example) to a warm area.    

A)

Install check valve and/or pressure relief valve between inlet
and outlet ports.

B)

Connect fluid outlet here.

C)

Connect fluid inlet here.

D)

NEVER

 install a foot valve on suction

tube!

Figure 3 

Содержание SOTERA SP100-10 Series

Страница 1: ...1 BSPP I I I I I I I I I I I I DRIVE MATERIAL OF CONSTRUCTION I I I I I I P POLYPROPYLENE I I I I I C GROUNDABLE NYLON I I I I I I I I I I WET END MATERIAL OF CONSTRUCTION I I I I I A ALUMINUM I I I...

Страница 2: ...ffler HAZARDOUS PRESSURE can cause serious injury or property damage Do not service or clean pump hoses or dispensing valve while the system is pressurized Disconnect air supply line and relieve press...

Страница 3: ...onal injury or property damage A filter capable of filtering out particles larger than 50 microns should be used on the air supply There is no lubrication required other than the O ring lubricant whic...

Страница 4: ...ghts or open flames near the work area keep a fire extinguisher close for quick access Ground Point Figure 1 Pump Grounding Ventilating Exhaust Air Figure 2 Diaphragm failure will cause the fluid bein...

Страница 5: ...ue all fasteners and rings prior to start up to ensure good fluid seal Proper torque is paramount to proper sealing DO NOT over torque fasteners and rings torque specifications are located on page 8 B...

Страница 6: ...ounded as illustrated A SP100 Air Operated Diaphragm Pump B Fluid drain valve recommended C Fluid regulator optional D Fluid tank drum barrel E Wall mount bracket KITS10WMA F Air filter regulator requ...

Страница 7: ...al of Construction Qty KITS10ONA 14 Outlet Aluminum NPT 1 KITS10OBA 14 Outlet Aluminum BSPP 1 KITS10ONM 18 Outlet Stainless Steel NPT 1 KITS10OBM 18 Outlet Stainless Steel BSPP 1 Outlet Kits Item Desc...

Страница 8: ...10NWP 11 9 1 Diaphragm Nut Back Up Washer Polypropylene Stainless Steel SS 1 1 KITS10NWD 11 9 1 Diaphragm Nut Back Up Washer Groundable Acetal Carbon Steel CS 1 1 Replacement Nut and Washer Item Torqu...

Страница 9: ...ody to ensure proper alignment Lubricate the diaphragm rod prior to installation use supplied LUBRIPLATE Super FML 2 When replacing PTFE diaphragms be certain to position the PTFE towards the fluid ca...

Страница 10: ...n in the outlet plumbing The pump must be mounted vertically for checks to properly work Check for pump cavitation the suction pipe should be sized at least as large as the inlet thread diameter The s...

Страница 11: ...351 08 mm A 12 765 342 23 mm B 6 798 172 67 mm C 7 125 180 98 mm D 10 610 269 49 mm E 1 250 31 75 mm F 8 697 220 90 mm G H 6 250 158 75 mm J 4 000 101 60 mm K 2 000 50 80 mm L 2 625 66 68 mm M 5 250...

Страница 12: ...k assessment and risk reduction BS EN 809 1998 Pumps and pump units for liquids Common safety requirements Models for use in ATmosphere EXplosive ATEX that comply with European standards 94 9 EC Direc...

Страница 13: ...I I I I I I I MATERIAL DE CONSTRUCCI N DEL CONDUCTOR P POLIPROPILENO I I I I I C NYLON CON CONEXI N A TIERRA I I I I I I I I I I MATERIAL DE CONSTRUCCI N DE EXTREMO H MEDO I I I I I A ALUMINIO I I I I...

Страница 14: ...n conexi n a tierra de 3 8 de di metro interno m nimo entre la bomba y el silenciador La PRESI N PELIGROSA puede provocar lesiones graves o da os a la propiedad No realice mantenimiento ni limpie la b...

Страница 15: ...bomba lesiones corporales o da os a la propiedad En el suministro de aire se debe usar un filtro capaz de filtrar part culas m s grandes que 50 micrones No se requiere otra lubricaci n adem s del lubr...

Страница 16: ...trabajo mantenga un extintor de incendios para acceder r pidamente a l Punto de conexi n a tierra Figura 1 Conexi n a tierra de la bomba Ventilaci n del aire de escape Las fallas del diafragma pueden...

Страница 17: ...los sellos de l quido est n buenos La torsi n adecuada es primordial para el sellado adecuado NO apriete en exceso los sujetadores y los anillos las especificaciones de torsi n se encuentran en la p...

Страница 18: ...gma SP100 B V lvula de drenaje de l quido recomendada C Regulador de l quido opcional D Tanque o tambor o barril de l quido E Soporte de montaje en pared KITS10WMA F Regulador de filtro de aire se req...

Страница 19: ...PT 1 KITS10OBA 14 Salida Aluminio BSPP 1 KITS10ONM 14 Salida Acero Inoxidable NPT 1 KITS10OBM 14 Salida Acero Inoxidable BSPP 1 Juegos de salida Elemento Descripci n Cant 1A Colector en U Buna N 3 4 x...

Страница 20: ...de refuerzo Acero inoxidable SS 1 11 Tuerca de diafragma de 1 Acetal con conexi n a tierra 1 KITS10NWD 9 Arandela de refuerzo Acero al carbono CS 1 Tuerca y arandela de repuesto Elemento Especificaci...

Страница 21: ...el de PTFE hacia la tapa de los l quidos Agregar un grado medio fijador de roscas a las roscas del v stago del diafragma tema 8 p gina 8 Agregar grado medio compuesto de bloqueo de roscas a pulm n la...

Страница 22: ...s o est n da adas La v lvula piloto no est orientada correctamente Aseg rese de cargar la v lvula piloto en la orientaci n adecuada seg n el diagrama que se ubica en el cuerpo central Suministro de ai...

Страница 23: ...822 351 08 mm A 12 765 342 23 mm B 6 798 172 67 mm C 7 125 180 98 mm D 10 610 269 49 mm E 1 250 31 75 mm F 8 697 220 90 mm G H 6 250 158 75 mm J 4 000 101 60 mm K 2 000 50 80 mm L 2 625 66 68 mm M 5 2...

Страница 24: ...uropeos 2006 42 CE Maquinaria BS EN ISO 12100 2010 Seguridad de m quinas Principios Generales para el dise o la evaluaci n y la reducci n de los riesgos BS EN 809 1998 bombas e instalaciones de bombeo...

Страница 25: ...I I B Rp 1 BSPP I I I I I I I I I I I I I I I I I I MAT RIAU DE CONSTRUCTION DES ENTRA NEMENTS P POLYPROPYL NE I I I I I C NYLON RACCORDABLE LA TERRE I I I I I I I I I I MAT RIAU DE CONSTRUCTION DES P...

Страница 26: ...tuyau raccord la terre de 9 5 mm 3 8 po de diam tre int rieur minimum entre la pompe et le silencieux LA PRESSION DANGEREUSE peut tre l origine de graves blessures ou d g ts mat riels N intervenez pas...

Страница 27: ...s blessures ou de d g ts mat riels Un filtre capable de filtrer des particules sup rieures 50 microns doit tre utilis sur l arriv e d air Il n y a pas d autre lubrification requise que celle du joint...

Страница 28: ...leuses ou de flammes nues pr s de la zone de travail Ayez toujours un extincteur port e de main Point de masse Figure 1 Raccordement la terre de la pompe Ventilation de l air vacu Figure 2 Lors d une...

Страница 29: ...esserrez toutes les attaches et les bagues avant la mise en marche pour vous assurer de la bonne tanch it du syst me aux fluides Le serrage ad quat est primordial pour une bonne tanch it NE PAS serrer...

Страница 30: ...la est illustr A Pompe membrane pneumatique SP100 B Robinet de vidange recommand C R gulateur de fluide facultatif D R servoir f t baril de fluide E Support de fixation mural KITS10WMA F R gulateur de...

Страница 31: ...luminium BSPP 1 KITS10INM 14 Sortie Acier Inoxydable NPT 1 KITS10OBM 14 Sortie Acier Inoxydable BSPP 1 Kits de sortie Article Description Qt 1A Rondelle l vre Buna N 3 4 x 1 x 1 8 2 1D Joint torique B...

Страница 32: ...1 9 Rondelle de retenue Acier inoxydable SS 1 11 crou de membrane 1 po Ac tal raccordable la terre 1 KITS10NWD 9 Rondelle de retenue Acier de carbone CS 1 crou et rondelle de rechange Article Sp cific...

Страница 33: ...E assurez vous de positionner l appui bleu de membrane vers le corps central et le PTFE vers le capuchon de gicleur Ajouter qualit moyenne compos de blocage pour filetage diaphragme la tige 8 les file...

Страница 34: ...nt pas endommag es Clapet pilote mal orient Assurez vous de monter le clapet pilote dans la bonne direction selon le sch ma qui se trouve dans le corps central Alimentation en air faible ou bloqu e V...

Страница 35: ...822 351 08 mm A 12 765 342 23 mm B 6 798 172 67 mm C 7 125 180 98 mm D 10 610 269 49 mm E 1 250 31 75 mm F 8 697 220 90 mm G H 6 250 158 75 mm J 4 000 101 60 mm K 2 000 50 80 mm L 2 625 66 68 mm M 5 2...

Страница 36: ...46809 1 800 634 2695 1 260 747 7524 Visitez notre site Web DC000967 000 R v 3 Conformit r glementaire La pompe membrane pneumatique 1 po SP100 de Sotera a t test e et elle est conforme aux normes str...

Страница 37: ...PTF 1 I I I I I I B Rp 1 BSPP I I I I I I I I I I I I WERKSTOFF ANTRIEB I I I I I I P POLYPROPYLEN I I I I I C LEITF HIGES NYLON I I I I I I I I I I WERKSTOFF BENETZTE TEILE I I I I I A ALUMINIUM I I...

Страница 38: ...d Schalld mpfer verwenden GEF HRLICHER DRUCK kann schwere Verletzungen oder Sachsch den verursachen Pumpe Schl uche oder Dispensventil nicht instandhalten oder reinigen wenn das System unter Druck ste...

Страница 39: ...verwendet werden der Teilchen mit einer Gr e von mindestens 50 m abscheiden kann Es ist keine Schmierung erforderlich ausgenommen das O Ring Schmiermittel das bei der Montage aufgetragen wird Falls g...

Страница 40: ...halten In der N he des Arbeitsbereichs d rfen keine Z ndflammen oder offene Flammen vorhanden sein einen Feuerl scher griffbereit halten Erdungsstelle Abb 1 Pumpenerdung Abf hren der Abluft Bei einem...

Страница 41: ...r Inbetriebnahme noch einmal festziehen um gute Fl ssigkeitsabdichtung zu gew hrleisten Der richtige Drehmomentwert ist f r optimale Dichtwirkung entscheidend Befestigungsteile und Ringe NICHT zu fest...

Страница 42: ...bildet geerdet werden A Druckluft Membranpumpe SP100 B Fl ssigkeitsablassventil empfohlen C Fl ssigkeitsregler optional D Fl ssigkeitstank Trommel Fass E Wandmontagehalterung KITS10WMA F Luftfilterreg...

Страница 43: ...ONA 14 Auslass Aluminium NPT 1 KITS10OBA 14 Auslass Aluminium BSPP 1 KITS10ONM 18 Auslass EdelstahlNPT 1 KITS10OBM 18 Auslass Edelstahl BSPP 1 Auslasss tze Teil Beschreibung Menge 1A Nutring Buna N 3...

Страница 44: ...tf Stahl SS 1 11 1 Zoll Membranmutter Actetal f r Masseanschluss geeignet 1 KITS10NWD 9 Unterlegscheibe Kohlenstoffstahl CS 1 Ersatzmutter und unterlegscheibe Teil Drehmomentwert 7 2 82 Nm 25 in lbs 1...

Страница 45: ...ML 2 verwenden Beim Ersetzen der PTFE Membrane sicherstellen dass die blaue Membranunterlage in Richtung mittleres Geh useteil und PTFE in Richtung Fl ssigkeitskappe platziert ist Hinzuf gen eines mit...

Страница 46: ...ausgerichtet Sicherstellen dass das Vorsteuerventil in der korrekten Ausrichtung eingesetzt wird siehe Zeichnung am mittleren Geh useteil Schwache oder blockierte Druckluftversorgung Druckluftversorg...

Страница 47: ...mm A 12 765 342 23 mm B 6 798 172 67 mm C 7 125 180 98 mm D 10 610 269 49 mm E 1 250 31 75 mm F 8 697 220 90 mm G H 6 250 158 75 mm J 4 000 101 60 mm K 2 000 50 80 mm L 2 625 66 68 mm M 5 250 133 35...

Страница 48: ...s im Web unter DC000967 000 Rev 3 EINHALTUNG GESETZLICHER VORSCHRIFTEN Die Sotera SP100 1 Zoll Druckluft Membranpumpe wurde getestet und entspricht den folgenden strikten Normen zur Zulassung Polyprop...

Отзывы: