4
Manual 1865 Rev B p/n 001865 0000
UNPACKING
Inspect the box and pump carefully for any signs
of damage incurred in transit. Since all pumps
are ordinarily shipped F.O.B. from our factory or
regional warehouse, such damage is normally the
responsibility of the carrier and should be reported
to them.
The vacuum pump is bolted to the skid. To free the
pump, remove the fasteners.
The inlet and exhaust of the pump are covered
with plastic caps to prevent dirt and other foreign
substances from entering the pump. Leave these
caps in place until you are ready to pipe the pump
to your equipment.
LOCATION
Install the pump in a horizontal position on a level
surface so that the pump is evenly supported on
its rubber feet. Leave 12 – 18 in. (30 – 46 cm) of
access around the pump to allow proper cooling.
Provide adequate ventilation for the fans, radiator,
and motor.
Allow easy access to the oil sight glass for
inspection of the oil level, and allow easy access to
the exhaust port for filter changes. Do not tip over
the pump if it is filled with oil.
POWER REQUIREMENTS
A schematic diagram for the electrical motor
terminal connections is located in the junction box
of the motor or on the motor nameplate.
Connect the motor according to the electrical
codes through a fused switch in order to protect
the motor against electrical or mechanical overload
conditions. Set the overload of the motor starter at
a level equal to the full load motor current listed on
the motor nameplate.
If the pump is supplied with a motor starter, it
is preset at the factory according to customer
specifications. Check that these settings are in line
with the voltage at your location. If the voltage is
different, please contact Tuthill Vacuum & Blower
Systems for motor and starter information.
Correct direction of rotation is marked by an arrow
on the motor fan housing and is counterclockwise
when looking at the motor from the motor’s fan
side.
OTE:
N
After electrical connections have been
made but before oil has been added,
check the rotation of the motor. If rotation
is backward, reverse any two leads of the
three at the power connection.
INSTALLATION
03
Содержание KINNEY KVA100
Страница 18: ...14 08 Exploded Views and Parts Lists Manual 1865 Rev B p n 001865 0000 KVA12 KVA21 EXPLODED VIEW DRAWING ...
Страница 20: ...16 08 Exploded Views and Parts Lists Manual 1865 Rev B p n 001865 0000 KVA25 KVA40 EXPLODED VIEW DRAWING ...
Страница 26: ...22 08 Exploded Views and Parts Lists Manual 1865 Rev B p n 001865 0000 KVA250 EXPLODED VIEW DRAWING ...
Страница 28: ...24 08 Exploded Views and Parts Lists Manual 1865 Rev B p n 001865 0000 KVA400 EXPLODED VIEW DRAWING ...
Страница 30: ...26 08 Exploded Views and Parts Lists Manual 1865 Rev B p n 001865 0000 KVA630 EXPLODED VIEW DRAWING ...
Страница 34: ......
Страница 35: ......