101
NOTE: The procedures that follow must be closely adhered to. Dam-
age due to improper battery replacement is not covered by the unit's
warranty.
When the battery is removed, settings and calculations for repetitive
dives will be retained in non volatile memory for subsequent opera-
tions.
MODULE REMOVAL FROM BOOT
If the Module is in a Console, bend the rubber Console Boot back to expose the edge of
the Module. If the Boot is flexible enough to permit, you may bend it back far enough to
scoop the Module out with your finger. Otherwise, it may be necessary to insert a blunt
screwdriver until the tip rests just underneath the Module. DO NOT pry the Module from
the Console! Slowly increase the pressure under the Module by releasing the tension on
the rubber Boot. The Module will slide up the screwdriver and exit the Console.
If the Module is in a Wrist Boot, it will be necessary to peel the lips of the Boot downward
off the Module while applying pressure from underneath, working it out slowly.
BATTERY REPLACEMENT
The Battery Compartment should only be opened in a dry and clean environment with
extreme care taken to prevent the entrance of moisture or dust. To prevent formation of
moisture in the Battery Compartment, it is recommended that the Battery be changed in an
environment equivalent to the local outdoor temperature and humidity (e.g., do not change
the Battery in an air conditioned environment, then take it outside during a hot sunny day).
Содержание Element II
Страница 1: ......
Страница 7: ...7 OVERVIEW...
Страница 15: ...15 FEATURES AND DISPLAYS...
Страница 21: ...21 SURFACE MODES...
Страница 53: ...53 NORM DIVE MODES...
Страница 61: ...61 CAUTIONARY MODES...
Страница 73: ...73 SWITCHING GAS MIXES...
Страница 77: ...77 NORM POST DIVE MODES...
Страница 81: ...81 GAUGE OPERATING MODE...
Страница 85: ...85 FREE DIVE OPERATING MODE...
Страница 99: ...99 GENERAL...
Страница 116: ......