![TurnOnGreen EVP1100 Series Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/turnongreen/evp1100-series/evp1100-series_user-manual_1182202040.webp)
11.1 Error and Warning Message
Status
Red
Remark
Input OVP
One flash followed
by a 3-sec pause
Please measure the input voltage to see if it
is higher than 275V
Input UVP
Two flashes
followed by a 3-sec
pause
Please measure the input voltage to see if it
is lower than 160V
Output OCP
Three flashes
followed by a 3-sec
pause
When the charging current on the car shows
overloaded, please disconnect the charging
gun and then try to initiate charging again.
If the situation recurs, please contact the
service personnel of the car maker for
identification of problems.
OTP
Four flashes
followed by a 3-sec
pause
If the temperature of the charger is abnormal,
please turn off the charger power to cool
down the machine before powering it on
again. If the situation recurs, please power off
and stop using the machine immediately, then
contact customer service.
RCD Abnormal
Five flashes
followed by a 3-sec
pause
Disengage the charging gun and try the
operation again. If the situation recurs, please
contact customer service.
Ground Fault
*1
Six flashes
followed by a 3-sec
pause
Please confirm the grounding status
*1
Control Pilot Fault
Flicker
When communication between the vehicle
and charger is abnormal, please disengage
the charging gun and operate again. If the
situation recurs, please contact customer
service.
MCU Self-Test Fail
Constantly Bright
Contact Customer Service
RCD Self-Test Fail
Constantly Bright
Contact Customer Service
Relay Self-Test Fail Constantly Bright
Contact Customer Service
RCD Abnormal
Stop Charging
*2
Constantly Bright
Contact Customer Service
*3
Output OCP
Stop Charging
*2
Constantly Bright
Contact Customer Service
*3
OTP
Stop Charging
Constantly Bright
Contact Customer Service
37
EVP1100 Series - User Manual