The following procedure should correct most fan wobble. Check
after each step.
1. Check that all blade and blade bracket screws are secure.
2. Most fan wobble problems are caused when blade levels are
unequal. Check this level by selecting a point on the ceiling
above the tip of one of the blades. Measure from a point on the
center of each blade to the point on the ceiling. Measure this
distance as shown in Figure 12. Rotate the fan until the next
blade is positioned for measurement. Repeat for each blade.
Measurements deviation should be within 1/8˝. Run the fan for
10 Minutes.
3. Use the enclosed Blade Balancing Kit if the blade wobble is
still noticeable.
1. Remove 1 of 3 screws from the mounting ring and loosen the
other 2 screws. (Do not remove)
2. Place the key holes on the mounting plate over the 2 screws
previously loosened from the mounting ring, turn mounting
plate until it locks in place at the narrow section of the key
holes. Secure by tightening the 2 screws previously loosened
and the one previously removed. (Fig. 13)
Blade Balancing
Attaching the Mounting Plate
Figure 12
Figure 13
Touching Ceiling
8
Screws
Mounting Ring
Mounting Plate