Lit. No. 75371, Rev. 01
22
October 1, 2018
TROUBLESHOOTING
TAILGATE SPREADER
Spreader
does not run
Fuse blown
Jammed auger
Check switch
Material issue
Dead short in
wiring
Auger
interference
Reconnect or
replace cable
Check battery
Fix or replace
Corrosion at
connection
Material will not
À
ow
Bad motor;
contact distributor
Loose
connection
Corrosion
Test direct power
(12V) to motor
Load test battery
Replace all
corroded
connections
Apply dielectric
grease
Material issue
Too much
amperage draw
Bad motor/trans
assembly
4A to 20A draw, no
load — good
>20A draw,
no load — bad
Bad electrical
connection
Tighten or replace
Apply dielectric
grease
Replace wiring
Bad transmission;
contact distributor
Turn shaft by hand;
should turn freely
Electrical
connection
Bad motor;
contact distributor
Loose or
unplugged
Содержание TS-300-1