turck TX700FB Скачать руководство пользователя страница 8

Note on the Product

Manufacturer and service

8

Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com

For further inquiries in Germany contact the Sales and Service Team on:

n

Sales: +49 208 4952-380

n

Technology: +49 208 4952-390

Outside Germany, please contact your local Turck representative.

Содержание TX700FB

Страница 1: ...Your Global Automation Partner Instructions for Use TX700FB HMI PLC Series for Food and Beverage...

Страница 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com...

Страница 3: ...s 13 4 4 1 Plug in extension modules 13 4 4 2 Power supply 13 4 4 3 USB accessory 13 5 Installing 14 5 1 Installation instructions 14 5 2 Fasten devices in the mounting cutout 15 5 3 Installing plug i...

Страница 4: ...YS 25 7 7 Programming with TX VisuPro 25 7 7 1 Transferring TX VisuPro to the device 26 8 Configuring 27 8 1 Configuring the system settings 27 9 Operating 29 9 1 LED displays 29 10 Troubleshooting 30...

Страница 5: ...RNING WARNING indicates a dangerous situation with medium risk of death or severe in jury if not avoided CAUTION CAUTION indicates a dangerous situation of medium risk which may result in minor or mod...

Страница 6: ...uct 2 1 Product identification These instructions apply to the following HMIs n TX707FB P3CV01 n TX715FB P3CV01 2 1 1 Type label The Type label is located on the back of the device Fig 1 Type label TX...

Страница 7: ...Nopen master Fig 2 Type code TX700 2 2 Scope of delivery n TX700 n Food compliant gasket n Power supply connector n Connector for serial interface n Mounting brackets n Quick Start Guide 2 3 Legal req...

Страница 8: ...mbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com For further inquiries in Germany contact the Sales and Service Team on n Sales 49 208 4952 380 n Technology 49 208 4952 390 Out...

Страница 9: ...erator panels of the F B series are suitable for use in the F B industry and comply with the standards and guidelines for hygienic design DIN EN1672 2 and EHEDG FDA 21 CFR 177 2006 The devices may onl...

Страница 10: ...connected via the extension slots A USB host port and an SD card slot are provided for using external storage me dia The TFT widescreen color display of the devices is designed as a capacitive multi...

Страница 11: ...ules for I Os and further communication interfaces 4 3 Functions and operating modes The CODESYS V3 control of the devices has the functions PROFINET controller EtherNet IP scanner and Modbus TCP as w...

Страница 12: ...100 Mbit 1 10 100 1000 Mbit n Extension slots for plug in modules 2 slots for max 4 plug in modules n Serial interface n Slot for SD card n USB port Compatible SD cards Specification Supported types S...

Страница 13: ...00002599 TX RS232 Serial interface for RS232 communication 100004786 TX EXTEND Bus extension electromechanical adapter for the use of the plug in module TX IO XX03 100009535 TX UMTS Wireless modem plu...

Страница 14: ...ce to direct sunlight for long periods of time to avoid overheating the device n Do not install the device in environments in which it is exposed to corrosive chemical sub stances In order to meet the...

Страница 15: ...re fixed in the mounting cutout with mounting brackets Mount the brackets as follows Fig 6 Insert the brackets Tighten the fastening screws until the brackets are firmly in contact with the device The...

Страница 16: ...modules 16 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com 5 3 Installing plug in modules Fig 7 Installing plug in modules e g TX CAN TX IO DX06 Fig 8 Installing p...

Страница 17: ...electromagnetic interference Ground the unit via the grounding screw near the power supply connection Grounding the power supply The power supply circuit may be floating or grounded To ground the sup...

Страница 18: ...is of sufficient capacity to operate the device Fig 10 TX7 FB connectors Port Description 1 USB port V2 0 max 500 mA 2 Ethernet port 2 10 100 Mbit 3 Ethernet port 1 10 100 Mbit 4 Serial interface 5 Et...

Страница 19: ...nnecting external devices to the serial interface The serial port is used to communicate with a PLC or with another type of device The following standards are available at the serial interface The typ...

Страница 20: ...channels n 1 serial interface n 1 CAN interface n 1 SPI interface NOTE It is not possible to stack two modules that are using the same type of interface The following table shows which plug in module...

Страница 21: ...MI all slots 6 4 1 Slot assignment CAN port Physical interface CODESYS parameter network Slot 1 Network 0 Slot 2 Network 0 Slot 3 Network 1 Slot 4 Network 1 6 4 2 Slot assignment serial interfaces Phy...

Страница 22: ...ot use sharp or pointed objects screwdrivers etc to operate the touch screen 7 3 Initial commissioning The Ethernet ports of the device are set to DHCP by default During the initial commissioning the...

Страница 23: ...via the Turck Service Tool 7 5 1 Setting the IP address via the web server Log in to the device s web server as described under Web server login Edit the network setting via System Settings Network E...

Страница 24: ...ting the IP address via Turck Service Tool Connect the device to the PC via the Ethernet interface Open Turck Service Tool Click Search or press F5 Fig 16 Turck Service Tool home screen a Turck Servic...

Страница 25: ...quisites n CODESYS V 3 5 14 0 and the package TXxxx HMI PLC series for the device have to be in stalled on a PC running Microsoft Windows 7 7 Programming with TX VisuPro Prerequisites n For programmin...

Страница 26: ...project to a device n Via Ethernet n Via a USB stick Project transfer via Ethernet Connect the HMI device to the computer with an Ethernet network Execute the command Run Download in TX VisuPro You m...

Страница 27: ...in Tap Tap mode see Recovery operation in the Adapting the system set tings 27 8 1 Configuring the system settings The available options can be selected from the navigation menu on the left side of t...

Страница 28: ...ngs menu System Information about platform status and timers like System on time backlight on time Logs Activating and exporting persistent log for BSP Date Time Date and time including time zone and...

Страница 29: ...splays The device has the following LED displays n Status of the Ethernet ports LED orange left LED Meaning off No Ethernet connection On Ethernet connection established LED green right LED Meaning On...

Страница 30: ...the device does not function as expected first check whether ambient interference is present If there is no ambient interference present check the connections of the device for faults If there are no...

Страница 31: ...eturns to Turck can only be accepted if the device has been equipped with a Decontamination declaration enclosed The decontamination declaration can be downloaded from https www turck de en retoure se...

Страница 32: ...core 800 MHz Operating system Linux RT Linux RT Flash 4 GB 8 GB RAM 1 GB 2 GB Expansion memory USB SD card USB SD card Real Time Clock Yes battery backed Yes battery backed Accuracy RTC at 25 C 100 p...

Страница 33: ...ag netic fields 80 MHz 1 GHz 10 V m 1 4 GHz 2 GHz 3 V m 2 GHz 2 7 GHz 1 V m EN 61000 4 3 Burst 2 kV DC power port 1 kV signal line EN 61000 4 4 Overvoltage 0 5 kV DC power port line to earth 0 5 kV DC...

Страница 34: ...e of 40 C or higher may result in a deterior ation in the quality reliability and durability of the backlight Display viewing angles The viewing angles are included in the technical data of the respec...

Страница 35: ...strial environments EN 61000 6 2 EN 61000 6 4 Food and Beverage Front panel and gasket n DIN EN1672 2 2 n EHEDG FDA 21 CFR 177 2006 UL cULus UL File No E484727 n UL 61010 1 3rd Edition and UL 61010 2...

Страница 36: ...Over 30 subsidiaries and over 60 representations worldwide www turck com 100022974 2020 11 100022974...

Отзывы: