turck TX507 Скачать руководство пользователя страница 17

17 

V01.01.01 | 2016/07 

All the electronic devices in the control system must be properly grounded. 

Grounding must be performed according to applicable regulations.

 NOTE

The power connector is part of the scope of delivery and can be ordered as spare part, 

see

 „15 Appendix: Accessories“ on page 22

.

Battery

These devices are equipped with rechargeable Lithium battery, not user-replaceable.

The following information is maintained by the battery:

 

Hardware  real-time clock (date and time)

Charge:

At first installation the battery must be charged for 48 hours.

When the battery is fully charged, it ensures a period of 3 months of data back-up at 25 °C. 

 NOTE

Dispose of batteries according to local regulations.

 

TX504E

 

Содержание TX507

Страница 1: ...Your Global Automation Partner Operating Instructions TX500 SERIES HMI...

Страница 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com...

Страница 3: ...507 E TX510 TX513 11 5 Installation 11 5 1 Installation environment 11 5 1 1 Applying the gasket 12 5 2 Mounting of the HMI 12 6 Electrical connectors 13 6 1 TX504E 13 6 2 TX507 E TX510 TX513 13 6 3 S...

Страница 4: ...52 264 more turck com www turck com 13 LED indicator on front panel 22 14 Unpacking and packing instructions 22 15 Appendix Accessories 22 15 1 Plug in extension modules 22 15 2 Mounting material incl...

Страница 5: ...1 Target groups This document is written for specially trained personnel and must be read carefully by anyone who is charged with the mounting commissioning operation maintenance disassembly or dispo...

Страница 6: ...e information is missing in the document please send your suggestions to techdoc turck com 2 Product overview The TX500 series HMI products combine state of the art features and top performance with a...

Страница 7: ...994847559 serial number 041802A19901157 version ID of the product 2 2 Type code TX 5 07 P3 CV 01 TX Product Series Product series TX Turck HMI PLC 5 Series Series 5 TX500 series E Processor Processor...

Страница 8: ...above regulations the products are CE marked 4 Technical data 4 1 Technical specifications HMI TX504E TX507 TX507E TX510 TX513 Touch screen technology resistive Display backlight TFT Color LED Colors...

Страница 9: ...alent to these standards oils that should have no effect on the TX500 can possibly harm the unit This can occur in areas where either va porized oils are present or where low viscosity cutting oil are...

Страница 10: ...25 C Extended use in environments where the surrounding air temperature is 40 C or higher may degrade backlight quality reliability durability Front foil without directly exposure to sunlight or UV ra...

Страница 11: ...rosive chemical compounds Check the resistance of the front panel film to a specific compound before installation Do not use tools of any kind screwdrivers etc to operate the touch screen of the panel...

Страница 12: ...rame Fig 1 TX504E TX507 E Fig 2 TX510 TX513 A gasket B installation cut out A gasket B installation cut out 5 2 Mounting of the HMI Place the fixing brackets as follows Screw each fixing screw until t...

Страница 13: ...it s 3 USB Port version 2 0 1 1 4 Power supply 5 Expansion slot for plug in modules 6 SD card slot 6 2 TX507 E TX510 TX513 Port Description 1 Serial port 2 2 x RJ45 Ethernet port 10 100 Mbit s 3 USB p...

Страница 14: ...serial port on the TX500 is referred to as COM1 Pin RS232 RS485 RS422 1 GND GND GND 2 n c n c n c 3 TxD A Tx 4 RxD Rx 5 n c n c n c 6 5 VDC output 5 VDC output 5 VDC output 7 CTS B Rx 8 RTS Tx 9 n c n...

Страница 15: ...T32 specification 4 GB for one single file 32 GB in total 7 Optional plug in modules Several optional plug in modules can be used with the TX500 panels Multiple module configu rations are possible Slo...

Страница 16: ...er supply grounding and shielding The power supply terminal block is shown in the figure below NOTE Ensure that the power supply has enough power capacity for the operation of the equipment The unit m...

Страница 17: ...see 15 Appendix Accessories on page 22 9 Battery These devices are equipped with rechargeable Lithium battery not user replaceable The following information is maintained by the battery Hardware real...

Страница 18: ...ap product Do not use solvents 11 Getting started The PLC and Visualization functionalities of the TX500 HMI series must be programmed with the CODESYS development tool which can be downloaded from ww...

Страница 19: ...ning on the HMI Advanced Mode Tap Tap Mode Advanced settings including the standard settings also accessible if a CODESYS TargetVisu is running on the HMI 12 1 Access of system settings in Standard Mo...

Страница 20: ...touchscreen during the device power up phase Tapping frequency must be high 2 Hz or more Start tapping the touchscreen as soon as power has been applied to the device When the sequence has been recog...

Страница 21: ...wnload Configuration OS Update the Configuration OS module of BSP Download Main OS Update the Main OS module of BSP Download Splash Image Replace the splash screen image displayed by the device at pow...

Страница 22: ...structions To repack the unit please follow the instructions backwards 15 Appendix Accessories 15 1 Plug in extension modules Ident no Type Description 6828210 TX CAN 1 CAN interface 6828203 TX IO DX0...

Страница 23: ...2GB SD card 2GB 6827348 USB 2 0 Industrial Memory Stick 1GB industrial USB stick 6827389 USB 2 0 EXTENSION 5M USB 2 0 extension cable male A to female A 5 meters 6827390 USB 2 0 EXTENSION ACTIVE 5M US...

Страница 24: ...D301397 2016 07 D301397 1607 with 28 subsidiaries and over 60 representations worldwide www turck com...

Отзывы: