![turck TX507 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/turck/tx507/tx507_operating-instructions-manual_1181790022.webp)
22
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
LED indicator on front panel
13 LED indicator on front panel
The LED in the front of the HMI can be controlled by the CODESYS Program using the Library
TX_MiscCommands which is included inside the TX500 CODESYS Package.
If the LED is not controlled out of CODESYS the standard behavior is:
Color
Status
Meaning
Green
ON
Normal Operation
Red
ON
Low Battery or Hardware fault
14 Unpacking and packing instructions
To repack the unit, please follow the instructions backwards.
15 Appendix: Accessories
15.1 Plug-in extension modules
Ident no.
Type
Description
6828210
TX-CAN
1 × CAN interface
6828203
TX-IO-DX06
8 × digital inputs, 24 VDC, pnp
6 × digital outputs, 24 VDC, 0.5 A, pnp
1 × relay output, NO
6828201
TX-IO-XX03
20 × digital inputs, 24 VDC, pnp
12 × digital outputs, 24 VDC, 0.5 A, pnp
8 × analog inputs, U, I, RTD, TC
4 × analog outputs, U, I
15.2 Mounting material incl power supply connector
Ident no.
Type
Description
6828220
TX-Mount-07
Mounting material for TX504E and TX507(E):
1 × power supply connector
4 × fixing brackets
6828221
TX-Mount-10
Mounting material for TX510:
1 × power supply connector
10 × fixing brackets