V01.00 | 2020/07
39
Con-
nector
at device
Channels
Type
I/O type
(Expert setting)
Later function (see application example
[
C0
FDI0/1
E-stop
Safe input (dry contact), double
channel forced
Safely switches off output at FDX8/9.
C1
FDI2/3
Light grid (AOPD) Safe input (OSSD), double chan-
nel forced
Safely switches off output at FDX8/9.
C2
FDI4
Standard input
Used for the monitored start after
switch-off of FDX8/9 and FDX10/11.
FDI5
Standard input
-
C3
FDI6/7
E-stop
Safe input (dry contact)
No function, reserved
C4
FDX8/9
Safe output
Safe output according to PLe
(test pulse every 500 milli-
seconds)
Is switched off safely if the E-Stop (at
FDI0/1) and/or the light grid at FDI2/3
are activated.
C5
FDX10/11
Safe output,
switch-off delay
Safe output (plus and minus
switching, no test pulses)
Is switched off safely, if the safety
sensor at FDX12/13 is activated. Signal
forwarding to F-CPU.
C6
FDX12/13
Safe sensor
Safe input (antivalent), double
channel dependent with filter-
ing
Safely switches off output at
FDX10/11.
C7
FDX14/15
unused
Adapt the expert settings and close with
OK
.